A Pulse Sequence for Improving MRI Images

被引:0
|
作者
Malik, Aamir Saeed [1 ]
Song, Taek Lyul [1 ]
机构
[1] Hanyang Univ, Dept Elect Informat Syst Engn, Ansan 426791, Kyunggido, South Korea
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Improving SNR as well as resolution simultaneously is a challenging problem in MRI. In normal EPI sequences, a long data acquisition time not only excessively attenuates the signal obtained from the sequence but also alters its resolution depending on the adjustment of the sequence. In this paper, we address this issue by designing a pulse sequence for GE-EPI (Gradient Echo - Echo Planar Imaging). Instead of starting acquisition from the maximum point in K-Space, the acquisition point is selected according to the requirement. For example, if good SNR is required than the acquisition point selected is close to zero so as to preserve the DC component.
引用
收藏
页码:225 / 228
页数:4
相关论文
共 50 条
  • [41] Improving the accuracy of estimates of the pulse sequence period using the methodology of complete sufficient statistics
    Zhuchkov, Konstantin
    Vasilchenko, Mikhail
    Zagrebneva, Anna
    Zavyalov, Alexey
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [42] Improving Brain Tumor Segmentation in MRI Images through Enhanced Convolutional Neural Networks
    Ayomide, Kabirat Sulaiman
    Aris, Teh Noranis Mohd
    Zolkepli, Maslina
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2023, 14 (04) : 670 - 678
  • [43] Implementation of the X-centric pulse sequence at low field for MRI of water penetration in clay
    Perron, Samuel
    Tully, Claire S.
    Gupta, Shivam
    Fox, Matthew S.
    Zagidulin, Dmitrij
    Noel, James J.
    Ouriadov, Alexei
    JOURNAL OF MAGNETIC RESONANCE, 2025, 373
  • [44] Dose resolution in radiotherapy polymer gel dosimetry:: effect of echo spacing in MRI pulse sequence
    Baldock, C
    Lepage, M
    Bäck, SÅJ
    Murry, PJ
    Jayasekera, PM
    Porter, D
    Kron, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 449 - 460
  • [45] Single shot three-dimensional pulse sequence for hyperpolarized 13C MRI
    Wang, Jiazheng
    Wright, Alan J.
    Hu, De-en
    Hesketh, Richard
    Brindle, Kevin M.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 740 - 752
  • [46] Missing MRI Pulse Sequence Synthesis Using Multi-Modal Generative Adversarial Network
    Sharma, Anmol
    Hamarneh, Ghassan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (04) : 1170 - 1183
  • [47] Impact of Pulse Sequence Selection On T1-Weighted MRI Radiomic Textural Features
    Yang, F.
    Ford, J.
    Dogan, N.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [49] PULSE SEQUENCE IDENTIFIER
    KOKES, A
    NUCLEAR INSTRUMENTS & METHODS, 1971, 92 (01): : 151 - &
  • [50] PULSE SEQUENCE GENERATOR
    VAKHRIN, MI
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (04): : 122 - 124