A Turn-On Fluorescence-Based Fibre Optic Sensor for the Detection of Mercury

被引:28
|
作者
Nguyen, T. Hien [1 ]
Sun, Tong [1 ]
Grattan, Kenneth T. V. [1 ]
机构
[1] City Univ London, Photon & Instrumentat Res Ctr, London EC1V 0HB, England
基金
英国工程与自然科学研究理事会;
关键词
optical fibre sensor; fluorescent sensor; mercury sensor; ion imprinted polymer; coumarin dye; WATER; IONS; HG2+; SOIL; CHEMOSENSOR; ZINC;
D O I
10.3390/s19092142
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The design, development, and evaluation of an optical fibre sensor for the detection of Hg2+ in aqueous media are discussed in detail in this paper. A novel fluorescent polymeric material for Hg2+ detection, based on a coumarin derivative (acting as the fluorophore) and an azathia crown ether moiety (acting as the mercury ion receptor), has been synthesized. The fluorophore was covalently immobilized onto the fibre surface by polymerisation using the ion imprinting technique and exhibited a significant increase in fluorescence intensity in response to Hg2+ via a photoinduced electron transfer (PET) mechanism. The sensor provided a response over a concentration range of 0-28 mu M with an acceptable response rate of around 11 min and a recovery rate of around 30 min in a Tris-EDTA buffer solution. A detection limit of 0.15 mu M was obtained with a possibility of improvement by changing the thickness of the polymer layer and using a more sensitive detector. High-quality performance is seen through a high selectivity for Hg2+ over other metal ions, excellent photo-stability and reversibility which was also demonstrated, making this type of sensor potentially well suited for in-situ monitoring of mercury in the environment.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] A turn-on and reversible fluorescence sensor for zinc ion
    Lin, Hsiang-Yi
    Cheng, Pi-Yun
    Wan, Chin-Feng
    Wu, An-Tai
    ANALYST, 2012, 137 (19) : 4415 - 4417
  • [32] A fluorescence "turn-on" sensor for detecting hydrazine in environment
    Jiang Xingzong
    Zhen, Lu
    Mingqin, Shangguan
    Yi Sili
    Zeng Xiaoyang
    Zhang Yongle
    Hou Linxi
    MICROCHEMICAL JOURNAL, 2020, 152
  • [33] A Dendron-Based Fluorescence Turn-On Probe for Tumor Detection
    Liu, Changren
    Zhang, Ling'e
    Zhou, Sensen
    Zhang, Xiaoke
    Wu, Wei
    Jiang, Xiqun
    CHEMISTRY-A EUROPEAN JOURNAL, 2020, 26 (57) : 13022 - 13030
  • [34] Tetraphenylethylene-based Glycoconjugate as a Fluorescence "Turn-On" Sensor for Cholera Toxin
    Hu, Xin-Ming
    Chen, Qi
    Wang, Jin-Xiang
    Cheng, Qian-Yi
    Yan, Chao-Guo
    Cao, Jie
    He, Yu-Jian
    Han, Bao-Hang
    CHEMISTRY-AN ASIAN JOURNAL, 2011, 6 (09) : 2376 - 2381
  • [35] Turn-on fluorescence sensor based on naphthalene anhydride for Hg2+
    Zhong, Zhimin
    Zhang, Dongdong
    Li, Dongmei
    Zheng, Gengxiu
    Tian, Zhongzhen
    TETRAHEDRON, 2016, 72 (49) : 8050 - 8054
  • [36] Conjugated polymer-based fluorescence turn-on sensor for nitric oxide
    Smith, RC
    Tennyson, AG
    Lim, MH
    Lippard, SJ
    ORGANIC LETTERS, 2005, 7 (16) : 3573 - 3575
  • [37] A Fluorescence Turn-on Sensor for Cyanide Anion Based on Exciplex Signaling Mechanism
    Zhou, Xianshu
    Yang, Hengquan
    Hao, Junsheng
    Yin, Caixia
    Liu, Diansheng
    Guo, Wei
    CHEMISTRY LETTERS, 2012, 41 (05) : 518 - 520
  • [38] BODIPY-Hg2+ Complex: A Fluorescence "Turn-ON" Sensor for Cysteine Detection
    Kumar, Monu
    Chaudhary, Garima
    Singh, Amit Pratap
    ANALYTICAL SCIENCES, 2021, 37 (02) : 283 - 292
  • [39] A self-calibrating sensor toward fluorescence turn-on detection of DMSO and nicosulfuron
    Liu, Wei
    Cong, Zhenzhong
    Liu, Gongchi
    Gao, Guoxu
    Zhang, Ying
    Wu, Shuangyan
    Gao, Enjun
    Zhu, Mingchang
    INORGANICA CHIMICA ACTA, 2021, 527
  • [40] Water-ratio directed selective turn-on fluorescence detection of copper and mercury in acetonitrile
    Toprak, Mahmut
    Lafzi, Ferruh
    Bayindir, Sinan
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2021, 418