Semi-automated retinal vessel analysis in nonmydriatic fundus photography

被引:13
|
作者
Schuster, Alexander Karl-Georg [1 ]
Fischer, Joachim Ernst [1 ]
Vossmerbaeumer, Urs [1 ,2 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Mannheim Inst Publ Hlth Social & Prevent Med, Mannheim, Germany
[2] Johannes Gutenberg Univ Mainz, Dept Ophthalmol, D-55131 Mainz, Germany
关键词
central retinal vessel equivalents; epidemiology; fundus photography; hypertensive retinopathy; imaging analyser; retinal vessel; VASCULAR CALIBER; MICROVASCULAR ABNORMALITIES; CARDIOVASCULAR RISK; OLDER POPULATION; BLOOD-PRESSURE; EYE; DIAMETERS; HYPERTENSION; RELIABILITY; ARTERIOLAR;
D O I
10.1111/aos.12242
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeFunduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. Methodsmatlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial-venous (A/V) ratio in the central vessel equivalent on 45 degrees digital fundus photographs. Validity and reproducibility of the results were ascertained using nonmydriatic photographs of 50 eyes from 25 subjects recorded from a 3DOCT device (Topcon Corp.). Two hundred and thirty-three eyes of 121 healthy subjects were evaluated to define normative values. ResultsA software tool was developed using image thresholds for vessel recognition and vessel width calculation in a semi-automated three-step procedure: vessel recognition on the photograph and artery/vein designation, width measurement and calculation of central retinal vessel equivalents. Mean vessel recognition rate was 78%, vessel class designation rate 75% and reproducibility between 0.78 and 0.91. Mean A/V ratio was 0.84. Application on a healthy norm cohort showed high congruence with prior published manual methods. Processing time per image was one minute. ConclusionsQuantitative geometrical assessment of the retinal vasculature may be performed in a semi-automated manner using dedicated software tools. Yielding reproducible numerical data within a short time leap, this may contribute additional value to mere morphological estimates in the clinical evaluation of fundus photographs.
引用
收藏
页码:E42 / E49
页数:8
相关论文
共 50 条
  • [31] Nonmydriatic ocular fundus photography among headache patients in an emergency department
    Thulasi, Praneetha
    Fraser, Clare L.
    Biousse, Valerie
    Wright, David W.
    Newman, Nancy J.
    Bruce, Beau B.
    NEUROLOGY, 2013, 80 (05) : 432 - 437
  • [32] Internal carotid artery occlusion with nonmydriatic fundus photography - A case report
    Tsai, DH
    Chang, CC
    Sheen, KC
    Tai, TY
    Chuang, LM
    DIABETES CARE, 2000, 23 (09) : 1429 - 1430
  • [33] Miniaturized indirect ophthalmoscopy for nonmydriatic wide-field fundus photography
    Toslak, Devrim
    Liu, Changgeng
    Alam, Minhaj Nur
    Yao, Xincheng
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [34] A semi-automated technique for labeling and counting of apoptosing retinal cells
    Mukhtar Bizrah
    Steve C Dakin
    Li Guo
    Farzana Rahman
    Miles Parnell
    Eduardo Normando
    Shereen Nizari
    Benjamin Davis
    Ahmed Younis
    M Francesca Cordeiro
    BMC Bioinformatics, 15
  • [35] Measuring arteriolar-to-venous ratio in retinal photography of patients with hypertension: Development and application of a new semi-automated method
    Pakter, HM
    Ferlin, E
    Fuchs, SC
    Maestri, MK
    Moraes, RS
    Nunes, G
    Moreira, LB
    Gus, M
    Fuchs, FD
    AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (03) : 417 - 421
  • [36] The Retinal Disease Screening Study: Retrospective Comparison of Nonmydriatic Fundus Photography and Three-Dimensional Optical Coherence Tomography for Detection of Retinal Irregularities
    Ouyang, Yanling
    Heussen, Florian M.
    Keane, Pearse A.
    Sadda, Srinivas R.
    Walsh, Alexander C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) : 5694 - 5700
  • [37] A semi-automated technique for labeling and counting of apoptosing retinal cells
    Bizrah, Mukhtar
    Dakin, Steve C.
    Guo, Li
    Rahman, Farzana
    Parnell, Miles
    Normando, Eduardo
    Nizari, Shereen
    Davis, Benjamin
    Younis, Ahmed
    Cordeiro, M. Francesca
    BMC BIOINFORMATICS, 2014, 15
  • [38] Detection of retinal pigment epithelial changes by nonmydriatic fundus cameras
    Salti, HIS
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (11) : 1615 - 1615
  • [39] Comparison of Nondiabetic Retinal Findings Identified With Nonmydriatic Fundus Photography vs Ultrawide Field Imaging in an Ocular Telehealth Program
    Silva, Paolo S.
    Cavallerano, Jerry D.
    Haddad, Nour Maya N.
    Tolls, Dorothy
    Thakore, Komal
    Patel, Bina
    Sehizadeh, Mina
    Tolson, Ann M.
    Sun, Jennifer K.
    Aiello, Lloyd Paul
    JAMA OPHTHALMOLOGY, 2016, 134 (03) : 330 - 334
  • [40] AUTOMATED AND SEMI-AUTOMATED PERIMETRY
    PRADINES, F
    DELBOSC, B
    ROYER, J
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1985, 8 (02): : 173 - 185