PurposeFunduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. Methodsmatlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial-venous (A/V) ratio in the central vessel equivalent on 45 degrees digital fundus photographs. Validity and reproducibility of the results were ascertained using nonmydriatic photographs of 50 eyes from 25 subjects recorded from a 3DOCT device (Topcon Corp.). Two hundred and thirty-three eyes of 121 healthy subjects were evaluated to define normative values. ResultsA software tool was developed using image thresholds for vessel recognition and vessel width calculation in a semi-automated three-step procedure: vessel recognition on the photograph and artery/vein designation, width measurement and calculation of central retinal vessel equivalents. Mean vessel recognition rate was 78%, vessel class designation rate 75% and reproducibility between 0.78 and 0.91. Mean A/V ratio was 0.84. Application on a healthy norm cohort showed high congruence with prior published manual methods. Processing time per image was one minute. ConclusionsQuantitative geometrical assessment of the retinal vasculature may be performed in a semi-automated manner using dedicated software tools. Yielding reproducible numerical data within a short time leap, this may contribute additional value to mere morphological estimates in the clinical evaluation of fundus photographs.
引用
收藏
页码:E42 / E49
页数:8
相关论文
共 50 条
  • [1] A semi-automated computer tool for the analysis of retinal vessel diameter dynamics
    Euvrard, Guillaume
    Genevois, Olivier
    Rivals, Isabelle
    Massin, Pascale
    Collet, Amelie
    Sahel, Jose-Alain
    Paques, Michel
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (05) : 513 - 523
  • [2] A semi-automated method for retinal vessel measurements.
    Quigley, MG
    Campeanu, RI
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S83 - S83
  • [3] Retinal Vessel Diameter Assessment in Papilledema by Semi-Automated Analysis of SLO Images: Feasibility and Reliability
    Moss, Heather E.
    Treadwell, Gillian
    Wanek, Justin
    DeLeon, Sherryl
    Shahidi, Mahnaz
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (04) : 2049 - 2054
  • [4] Nonmydriatic Ocular Fundus Photography in Neurologic Emergencies
    Bruce, Beau B.
    Biousse, Valerie
    Newman, Nancy J.
    JAMA NEUROLOGY, 2015, 72 (04) : 455 - 459
  • [5] Nonmydriatic Ocular Fundus Photography in the Emergency Department
    Bruce, Beau B.
    Lamirel, Cedric
    Wright, David W.
    Ward, Antoinette
    Heilpern, Katherine L.
    Biousse, Valerie
    Newman, Nancy J.
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (04): : 387 - 389
  • [6] Concordance between SIVA, IVAN, and VAMPIRE Software Tools for Semi-Automated Analysis of Retinal Vessel Caliber
    Mautuit, Thibaud
    Cunnac, Pierre
    Cheung, Carol Y.
    Wong, Tien Y.
    Hogg, Stephen
    Trucco, Emanuele
    Daien, Vincent
    MacGillivray, Thomas J.
    Labarere, Jose
    Chiquet, Christophe
    DIAGNOSTICS, 2022, 12 (06)
  • [7] Semi-automated computer analysis of retinal vessels in premature infants
    Turior, Rashmi
    Chutinantvarodom, Pornthep
    Uyyanonvara, Bunyarit
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 2962 - 2968
  • [8] Nonmydriatic Fundus Photography in Patients with Acute Vision Loss
    Vasseneix, Caroline
    Bruce, Beau B.
    Bidot, Samuel
    Newman, Nancy J.
    Biousse, Valerie
    TELEMEDICINE AND E-HEALTH, 2019, 25 (10) : 911 - 916
  • [9] NONMYDRIATIC FUNDUS PHOTOGRAPHY IN DETECTION OF DIABETIC-RETINOPATHY
    RYDER, REJ
    BRITISH MEDICAL JOURNAL, 1987, 294 (6563): : 58 - 58
  • [10] Semi-automated computer analysis of vessel growth in preterm infants with ROP
    Swanson, CR
    Cocker, KD
    Parker, KH
    Moseley, MJ
    Wren, SME
    Fielder, AR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U285 - U285