Three-Phase Grid-Connected Inverter Power Control under Unbalanced Grid Conditions Using a Time-Domain Symmetrical Components Extraction Method

被引:3
|
作者
Alathamneh, Mohammad [1 ]
Ghanayem, Haneen [1 ]
Yang, Xingyu [1 ]
Nelms, R. M. [1 ]
机构
[1] Auburn Univ, Dept Elect & Comp Engn, Auburn, AL 36849 USA
关键词
active filters; bidirectional power flow; DC-AC power converters; parameter extraction; power control; power conversion; voltage-source converters;
D O I
10.3390/en15196936
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Presented in this paper is a method of bidirectional real and reactive power control of a three-phase grid-connected inverter under unbalanced grid situations. Unbalanced three-phase load and unbalanced grid impedance are illustrations of unbalanced grid issues that have been investigated. As a result, both grid currents and point-of-common-coupling (PCC) voltages will be unbalanced. The real and reactive power that is delivered to the grid oscillates by a significant amount in these unbalanced conditions. A time-domain symmetrical components extraction approach is used to calculate the inverter's reference currents from the negative- and zero-sequence components of the measured currents. The suggested approach corrects unbalanced grid currents and unbalanced PCC voltages, and provides the desired real and reactive power to the grid when unbalanced situations exist. As a consequence, power oscillations will be eliminated, and power control will be possible. The suggested method's performance is supported by simulation, and various experimental results are obtained utilizing the dSPACE DS1202 real-time interface platform.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Symmetrical components-based robust stabilizing control of a grid-connected inverter under unbalanced voltage sag
    Choeung, Chivon
    Danayiyen, Yahya
    Srang, Sarot
    Lee, Young-Il
    JOURNAL OF ENGINEERING-JOE, 2024, 2024 (08):
  • [42] Power Control in Three-Phase Grid-Connected Current-Source Boost Inverter
    Saghaleini, Mahdi
    Mirafzal, Behrooz
    2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 776 - 783
  • [43] Reactive Power Control in Three-Phase Grid-Connected Current Source Boost Inverter
    Saghaleini, Mahdi
    Mirafzal, Behrooz
    2012 TWENTY-SEVENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2012, : 904 - 910
  • [44] The Sliding Mode Control Method of Grid-Connected Inverter Applied to Three-Phase Intermittent Power Supply
    Lei Jianing
    Su Shiping
    Liu Guiying
    Qin Zhiqing
    Dong Hang
    PROCEEDINGS OF THE 29TH CHINESE CONTROL CONFERENCE, 2010, : 4885 - 4888
  • [45] Three Reference Frame Control Scheme of 4 wire Grid-connected Inverter for Micro Grid Under Unbalanced Grid Voltage Conditions
    Song, Xianwen
    Wang, Yue
    Hu, Weihao
    Wang, Zhaoan
    APEC: 2009 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1- 4, 2009, : 1301 - 1305
  • [46] Research on MRSMC for Three-phase Grid-Connected Inverter
    Hu, Qinjun
    Zhang, Zhilin
    Liu, Hua
    Zhang, Liang
    2019 IEEE INTERNATIONAL SYMPOSIUM ON PREDICTIVE CONTROL OF ELECTRICAL DRIVES AND POWER ELECTRONICS (PRECEDE 2019), 2019, : 304 - 307
  • [47] Design and Control Scheme of Three-phase Photovoltaic Grid-connected Inverter
    Meng Wei
    Meng Lei
    Chen Changzhe
    ADVANCES IN APPLIED SCIENCES AND MANUFACTURING, PTS 1 AND 2, 2014, 850-851 : 445 - +
  • [48] A fault diagnosis method for three-phase photovoltaic grid-connected inverter
    Geng, Yiwen, 1600, China Machine Press (29):
  • [49] Synchronous PI Control for Three-phase Grid-connected Photovoltaic Inverter
    Liang, Ma
    Zheng, Trillion Q.
    2010 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-5, 2010, : 2302 - 2307
  • [50] Outer loop voltage control method based on dc power control of three-phase grid-connected inverter
    Du, Jifei
    Zhao, Hongyan
    Trillion, Q. Zheng
    Sun, Hu
    Li, Danyong
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (09): : 2622 - 2629