Operative guidelines for the reconstruction of the native glenoid plane: an anatomic three-dimensional computed tomography-scan reconstruction study

被引:18
|
作者
Verstraeten, Tom R. G. M. [1 ]
Deschepper, Ellen [2 ]
Jacxsens, Matthijs [1 ]
Walravens, Stig [1 ]
De Coninck, Brecht [1 ]
De Wilde, Lieven F. [1 ]
机构
[1] Univ Ziekenhuis Gent, Dept Orthoped Surg & Traumatol, B-9000 Ghent, Belgium
[2] Univ Ghent, Biostat Unit, B-9000 Ghent, Belgium
关键词
Anthropometric; glenoid center; 3D CT scan; glenoid plane; biconcave glenoid; shoulder arthroplasty; TOTAL SHOULDER ARTHROPLASTY; GLENOHUMERAL JOINT; PROSTHETIC DESIGN; PROXIMAL HUMERUS; BONE LOSS; OSTEOARTHRITIS; VERSION; SCAPULA; GEOMETRY; VAULT;
D O I
10.1016/j.jse.2011.10.030
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Reconstruction of the native plane in biconcave eroded glenoids is difficult. Nevertheless, accurate reconstruction of this plane is imperative for successful total shoulder arthroplasty. This study aims to determine guidelines that can increase the accuracy of glenoid component positioning. Methods: Three different circular planes were determined on 3-dimensional computed tomography (CT) scans of 152 healthy shoulders. First, the circular max (CM) plane is formed with the superior tubercle and 2 points, 1 anterior and 1 posterior, at the rim of the inferior third of the glenoid. Second, the circular inferior (CI) plane is formed by 3 points at the inferior 2 quadrants of the glenoid rim. Third, the circular minima (Cm) plane is formed with 3 points situated at the noneroded sector of the anterior glenoid. The angulation of the spinal scapular axis (SSA), the line between the most medial point of the scapular spine and the center of the three different glenoid planes, and the correlation coefficient between the radius of the circle and the length of SSA are calculated. Results: Angle SSA in the x-axis were 94 degrees, 93 degrees, 93 degrees and in the y-axis were 95 degrees, 111 degrees, and 111 degrees for CM, CI, and Cm, respectively. Correlation coefficient between the radius of the circle and the length of SSA: r = 0.69 for CM, r = 0.75 for CI, and r = 0.75 for Cm. Conclusion: Three points situated at the native anterior glenoid can reconstruct, within 2 degrees accuracy (95% confidence interval, 1.8 degrees-2.3 degrees), the CI plane. A relationship exists between the radii of the 3 glenoid circles and the width of the scapula (SSA length). Level of evidence: Basic Science Study, Anatomic Study, Imaging. (C) 2012 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1565 / 1572
页数:8
相关论文
共 50 条
  • [41] Anthropometric three-dimensional computed tomography reconstruction measurements of the acetabulum in children/adolescents
    Darwich, Ali
    Bdeir, Mohamad
    Janssen, Sonja
    Schoenberg, Stefan
    Gravius, Sascha
    Jawhar, Ahmed
    ACTA ORTHOPAEDICA BELGICA, 2022, 88 (01): : 1 - 9
  • [42] Three-dimensional reconstruction of the human upper airway from computed tomography images
    Lin, Jiang
    Hu, Guilin
    Shen, Huahao
    Fan, Jianren
    7TH INTERNATIONAL CONFERENCE ON COMPUTER-AIDED INDUSTRIAL DESIGN & CONCEPTUAL DESIGN, 2006, : 408 - 412
  • [43] Three-dimensional reconstruction computed tomography in thoracoscopic segmentectomy: a randomized controlled trial
    Chen, Kai
    Niu, Zhenyi
    Jin, Runsen
    Nie, Qiang
    Gong, Xian
    Du, Mingyuan
    Jiang, Benyuan
    Zheng, Bin
    Chen, Chun
    Zhong, Wenzhao
    Li, Hecheng
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2024, 66 (01)
  • [44] Identification Using Frontal Sinus by Three-Dimensional Reconstruction from Computed Tomography
    Kim, Deog-Im
    Lee, U-Young
    Park, Sang-Ouk
    Kwak, Dae-Soon
    Han, Seung-Ho
    JOURNAL OF FORENSIC SCIENCES, 2013, 58 (01) : 5 - 12
  • [45] Colon dissection:: a new three-dimensional reconstruction tool for computed tomography colonography
    Röttgen, R
    Fischbach, F
    Plotkin, M
    Herzog, H
    Freund, T
    Schröder, RJ
    Felix, R
    ACTA RADIOLOGICA, 2005, 46 (03) : 222 - 226
  • [46] Three-dimensional multidetector computed tomography reconstruction of an idiopathic pulmonary artery aneurysm
    Affronti, Alessandro
    Ramoni, Enrico
    Panuccio, Giuseppe
    Rossi, Alessia
    Paris, Marco
    Ragni, Temistocle
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2008, 9 (12) : 1287 - 1289
  • [47] Computed tomography three-dimensional reconstruction in the diagnosis of traumatic renal artery thrombosis
    Haas, CA
    Newman, J
    Spirnak, JP
    UROLOGY, 1999, 54 (03) : 559 - 560
  • [48] Glenoid morphology in obstetrical brachial plexus lesion: a three-dimensional computed tomography study
    Frich, Lars H.
    Schmidt, Pernille H.
    Torfing, Trine
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (08) : 1374 - 1382
  • [49] Three-dimensional reconstruction in electrical impedance tomography
    Liu, W.P.
    Hua, P.
    Webster, J.G.
    Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 131 - 135
  • [50] Three-dimensional Image Reconstruction in Electrical Tomography
    Yue, Shihong
    Gao, Jianling
    2013 10TH INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS AND KNOWLEDGE DISCOVERY (FSKD), 2013, : 246 - 250