Investigation on feasibility of ionic liquids used in solar liquid desiccant air conditioning system

被引:79
|
作者
Luo, Yimo [2 ]
Shao, Shuangquan [1 ]
Qin, Fei [1 ,3 ]
Tian, Chongqing [1 ]
Yang, Hongxing [2 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[2] Hong Kong Polytech Univ, RERG, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
[3] Chinese Acad Sci, Grad Univ, Beijing 100190, Peoples R China
关键词
Solar air conditioning; Liquid desiccant; Dehumidification; Ionic liquid; Bmim]BF4; Dmim]OAc; PHYSICAL-PROPERTIES; TERNARY-SYSTEMS; BINARY; DEHUMIDIFICATION; PERFORMANCE; EQUILIBRIA; WATER;
D O I
10.1016/j.solener.2012.06.008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The corrosion problem of traditional liquid desiccants hinders the development of solar liquid desiccant air conditioning system. Ionic liquids (ILs) could be a possible substitute because of their low corrosion to metals. According to the characteristic of cation and anion, two ILs 1-butyl-3-methylimidazolium tetrafluoroborate ([Bmim]BF4) and 1,3-dimethylimidazolium acetate ([Dmim]OAc) were selected for possibility investigation. The experimental results demonstrated that the surface vapor pressure of [Bmim]BF4 aqueous solution was so high that it was not suitable for dehumidification. With comparing the Structure of [Bmim]BF4 and 1-ethyl-3-methylimidazolium tetrafluoroborate ([Emim]BF4), it was found that for imidazole salts with the same anion, as the alkyl chain of the cation becomes shorter, the surface vapor pressure of its aqueous solution would be lower. In addition, simulation model was used to compare the dehumidification performance of [Dmim]OAc and [Emim]BF4 with that of the traditional desiccants lithium Chloride (LiCl) and lithium bromide (LiBr). The results showed that in the same condition, [Dmim]OAc with an inlet mass concentration of 81.7% and [Emim]BF4 of 85.5% could reach the same dehumidification rate as LiCl of 40.9% and LiBr of 45.0% mass concentration. Better dehumidification performance of [Dmim]OAc than that of [Emim]BF4 was achieved, thus, like [Emim]BF4, [Dmim]OAc can also be a promising substitute for traditional desiccant. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2718 / 2724
页数:7
相关论文
共 50 条
  • [21] A new solar coupling regeneration method for liquid desiccant air-conditioning system
    程清
    张小松
    许尧
    JournalofCentralSouthUniversity, 2014, 21 (08) : 3214 - 3224
  • [22] Development and application of a dynamic model for a solar assisted liquid desiccant air conditioning system
    Zhong, Dan
    Wen, Tao
    She, Xiaohui
    Chen, Yi
    Wang, Meng
    Yang, Hongxing
    Luo, Yimo
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (02) : 128 - 138
  • [23] Thermo-economic performance of a solar membrane liquid desiccant air conditioning system
    Abdel-Salam, Ahmed H.
    Ge, Gaoming
    Simonson, Carey J.
    SOLAR ENERGY, 2014, 102 : 56 - 73
  • [24] Feasibility study of desiccant air-conditioning system in Thailand
    Hirunlabh, J.
    Charoenwat, R.
    Khedari, J.
    Teekasap, Sombat
    BUILDING AND ENVIRONMENT, 2007, 42 (02) : 572 - 577
  • [25] Liquid desiccant air conditioning system with natural convection
    Fazilati, Mohammad Ali
    Alemrajabi, Ali Akbar
    Sedaghat, Ahmad
    APPLIED THERMAL ENGINEERING, 2017, 115 : 305 - 314
  • [26] AN EXPERIMENTAL INVESTIGATION INTO A SOLAR ASSISTED DESICCANT-EVAPORATIVE AIR-CONDITIONING SYSTEM
    JOUDI, KA
    MADHI, SM
    SOLAR ENERGY, 1987, 39 (02) : 97 - 107
  • [27] Development and modelling of a solar assisted liquid desiccant dehumidification air-conditioning system
    Mohaisen, Aqeel Kareem
    Ma, Zhenjun
    BUILDING SIMULATION, 2015, 8 (02) : 123 - 135
  • [28] Investigation of a compact hybrid liquid-desiccant air-conditioning system for return air dehumidification
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    BUILDING AND ENVIRONMENT, 2021, 187
  • [29] Solar Air Conditioning System Using Desiccant Wheel Technology
    Rachman, Arfidian
    Mat, Sohif
    Iskandar, Taib
    Yahya, M.
    Zaharim, Azami
    Sopian, Kamaruzzaman
    SELECTED TOPICS IN SYSTEM SCIENCE AND SIMULATION IN ENGINEERING, 2010, : 419 - 423
  • [30] Study on Solar Liquid Desiccant Air-conditioning Systems in Xiamen
    Hong, Xiaoqiang
    Li, Li
    He, Wenqiong
    Ge, Yuxiao
    Xu, Siwei
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2807 - 2814