A preliminary evaluation of attenuated total reflection Fourier transform infrared spectroscopy for the hematological analysis of thalassemias

被引:11
|
作者
Wan, Jun-Hui [1 ]
Tian, Pei-Ling [2 ]
Yin, Hao [3 ]
Han, Yun [3 ]
Wei, Xiang-Cai [2 ]
Pan, Tao [3 ]
机构
[1] Prenatal Diag Ctr, Guangzhou Women & Childrens Med Ctr, Guangzhou 510623, Guangdong, Peoples R China
[2] Family Planning Res Inst Guangdong, Guangzhou 510515, Guangdong, Peoples R China
[3] Jinan Univ, Guangdong Higher Educ Inst, Key Lab Optoelect Informat & Sensing Technol, Guangzhou 510632, Guangdong, Peoples R China
关键词
ATR-FTIR; Hemoglobin; Mean corpuscular volume; Mean corpuscular hemoglobin; Thalassemia; BETA-THALASSEMIA; IN-SITU; DIAGNOSIS; ALPHA; IDENTIFICATION; TOOL;
D O I
10.1016/j.clinbiochem.2012.10.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: The effectiveness of attenuated total reflection Fourier transform infrared spectroscopy for the hematological analysis of thalassemias was evaluated. Design and methods: The correlations of hemoglobin, mean corpuscular volume and mean corpuscular hemoglobin between routine method and attenuated total reflection Fourier transform infrared spectroscopy were analyzed using linear regression analysis. Appropriate cut-off values of predicted mean corpuscular volume and predicted mean corpuscular hemoglobin in screening of thalassemias were derived from the receiver operator characteristic curve conducted on 103 subjects. Results: Obvious positive correlations of hemoglobin (beta = 0.876, R-2=0.791, P<0.001), mean corpuscular volume (beta = 0.658, R-2=0.516, P<0.001) and mean corpuscular hemoglobin (beta = 0.674, R-2=0.583, P<0.001) were observed between routine method and attenuated total reflection Fourier transform infrared spectroscopy. Based on the receiver operator characteristic curve analysis, the best cut off value of predicted mean corpuscular volume for the phenotype-positive subjects was found to be 79.9 fl with & sensitivity of 100.0% and-a specificity of 97.8%, and the proposed cut off value of predicted mean corpuscular hemoglobin was 27.3 pg with a sensitivity of 100.0% and a specificity of 96.8%. The area under curve was 0.996 for predicted mean corpuscular volume and 0.992 for predicted mean corpuscular hemoglobin, respectively. Conclusions: The established method could be an additional potentially promising tool for the preliminary screening of thalassemias in population prevention and control program. The main advantage of this method is no unwanted chemical regents compared with conventional method. Strategy for the development of this method could be of use for the other important parameters of thalassemias. (C) 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:128 / 132
页数:5
相关论文
共 50 条
  • [41] Separation of underdeveloped from developed cotton fibers by attenuated total reflection Fourier transform infrared spectroscopy
    Liu, Yongliang
    Kim, Hee-Jin
    MICROCHEMICAL JOURNAL, 2020, 158
  • [42] Early detection of cell activation events by means of attenuated total reflection Fourier transform infrared spectroscopy
    Titus, Jitto
    Filfili, Chadi
    Hilliard, Julia K.
    Ward, John A.
    Perera, A. G. Unil
    APPLIED PHYSICS LETTERS, 2014, 104 (24)
  • [43] Attenuated total reflection Fourier transform infrared spectroscopy: A method of choice for studying membrane proteins and lipids
    Tatulian, SA
    BIOCHEMISTRY, 2003, 42 (41) : 11898 - 11907
  • [44] DETERMINATION OF BLOOD-GLUCOSE BY ATTENUATED TOTAL REFLECTION FOURIER-TRANSFORM INFRARED-SPECTROSCOPY
    KRUSEJARRES, JD
    JANATSCH, G
    GLESS, U
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1988, 26 (11): : 756 - 756
  • [45] Discrimination of soil-borne fungi using Fourier transform infrared attenuated total reflection spectroscopy
    Linker, Raphael
    Tsror, Leah
    APPLIED SPECTROSCOPY, 2008, 62 (03) : 302 - 305
  • [46] Attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR) in muscle diseases
    Zanna, G.
    Sancricca, C.
    Primiano, A.
    Gervasoni, J.
    Urbani, A.
    Marini, F.
    Sabino, A.
    Calvani, R.
    Servidei, S.
    Primiano, G.
    EUROPEAN JOURNAL OF NEUROLOGY, 2023, 30 : 585 - 585
  • [47] Authentication of sweetness of mango juice using Fourier transform infrared-attenuated total reflection spectroscopy
    Jha, S. N.
    Gunasekaran, S.
    JOURNAL OF FOOD ENGINEERING, 2010, 101 (03) : 337 - 342
  • [48] Attenuated total reflection (ATR) Fourier transform infrared spectroscopy of dimyristoyl phosphatidylserine-cholesterol mixtures
    Bach, D
    Miller, IR
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2001, 1514 (02): : 318 - 326
  • [49] Cell discrimination by attenuated total reflection-Fourier transform infrared spectroscopy: The impact of preprocessing of spectra
    Gaigneaux, A.
    Ruysschaert, J. M.
    Goormaghtigh, E.
    APPLIED SPECTROSCOPY, 2006, 60 (09) : 1022 - 1028
  • [50] Evaluation of seed oil quality in Iris lactea by attenuated total reflection-Fourier transform infrared spectroscopy coupled with chemometrics
    Long, Ruolan
    Luan, Zhenjie
    Feng, Dan
    Li, Peipei
    Sun, Jing
    SPECTROSCOPY LETTERS, 2023, 56 (08) : 444 - 451