Hepatic sinusoid plays a vital role in human cavernous hemangioma of the liver (CHL), and its morphologic investigation facilitates the understanding of microcirculation mechanism and pathological change of CHL. However, precise anatomical view of the hepatic sinusoid has been limited by the resolution and contrast available from existing imaging techniques. While liver biopsy has traditionally been the reliable method for the assessment of hepatic sinusoids, the invasiveness and sampling error are its inherent limitations. In this study, imaging of CHL samples was performed using in-line phase-contrast imaging (ILPCI) technique with synchrotron radiation. ILPCI allowed clear visualization of soft tissues and revealed structural details that were invisible to conventional radiography. Combining the computed tomography (CT) technique, ILPCI-CT was used to acquire the high-resolution micro-CT images of CHL, and three dimensional (3D) microstructures of hepatic sinusoids were provided for the morphologic depiction and quantitative assessment. Our study demonstrated that ILPCI-CT could substantially improve the radiographic contrast of CHL tissues in vitro with no contrast agent. ILPCI-CT yielded high-resolution micro-CT image of CHL sample at the micron scale, corresponding to information on actual structures revealed at histological section. The 3D visualization provided an excellent view of the hepatic sinusoid. The accurate view of individual hepatic sinusoid was achieved. The valuable morphological parameters of hepatic sinusoids, such as thrombi, diameters, surface areas and volumes, were measured. These parameters were of great importance in the evaluation of CHL, and they provided quantitative descriptors that characterized anatomical properties and pathological features of hepatic sinusoids. The results highlight the high degree of sensitivity of the ILPCI-CT technique and demonstrate the feasibility of accurate visualization of hepatic sinusoids. Moreover, there is a correlation between the CHL and the size or morphology of hepatic sinusoids, which offers a potential use in noninvasive study and analysis of CHL.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] X-ray microtomography (micro-CT): a reference technology for high-resolution quantification of xylem embolism in trees
    Cochard, H.
    Delzon, S.
    Badel, E.
    PLANT CELL AND ENVIRONMENT, 2015, 38 (01): : 201 - 206
  • [42] Desktop micro-CT with a nanotube field emission x-ray source for high-resolution cardiac imaging
    Cao, Guohua
    Calderon-Colon, Xiomara
    Burk, Laurel
    Lee, Yueh Z.
    Sultana, Shabana
    Lu, Jianping
    Zhou, Otto
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [43] Morphological examination of abdominal vertebral bodies from grass carp using high-resolution micro-CT scans
    Barak, Meir M.
    Schlott, James
    Gundersen, Laura
    Diaz, Giovanni
    Rhee, Vanessa
    Villoth, Naomi
    Ferber, Alexandra
    Blair, Salvatore
    JOURNAL OF ANATOMY, 2024, 245 (01) : 84 - 96
  • [44] High-resolution three-dimensional visualization of the rat spinal cord microvasculature by synchrotron radiation micro-CT
    Hu, Jianzhong
    Cao, Yong
    Wu, Tianding
    Li, Dongzhe
    Lu, Hongbin
    MEDICAL PHYSICS, 2014, 41 (10)
  • [45] Hopfield networks in relevance and redundancy feature selection applied to classification of biomedical high-resolution Micro-CT images
    Auffarth, Benjamin
    Lopez, Maite
    Cerquides, Jesus
    ADVANCES IN DATA MINING, PROCEEDINGS: MEDICAL APPLICATIONS, E-COMMERCE, MARKETING, AND THEORETICAL ASPECTS, 2008, 5077 : 16 - 31
  • [46] A biomechanical study of osteoporotic vertebral trabecular bone: The use of micro-CT and high-resolution finite element analysis
    Woo, Dae Gon
    Won, Ye-Yeon
    Kim, Han Sung
    Lim, Dohyung
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2007, 21 (04) : 593 - 601
  • [47] DETECTING METASTASIS OF GASTRIC CARCINOMA USING HIGH-RESOLUTION MICRO-CT SYSTEM: IN VIVO SMALL ANIMAL STUDY
    Liu, Junting
    Tian, Jie
    Liang, Jimin
    Li, Xiangsi
    Yang, Xiang
    Chen, Xiaofeng
    Chen, Yi
    Zhou, Yuanfeng
    Wang, Xiaorui
    MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [48] Quantitative Micro-CT Image Matching Assessment Of Regional Lung Mechanics In Mice
    Choi, J.
    Lin, C. -L.
    Newell, J. D.
    Puliyakote, A. S. Kizhakke
    Poeschinger, T.
    Tessier, J.
    Hoffman, E. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [49] Quantitative assessment of the vertebral pneumaticity in an anhanguerid pterosaur using micro-CT scanning
    Richard Buchmann
    Borja Holgado
    Gabriela Sobral
    Leonardo dos Santos Avilla
    Taissa Rodrigues
    Scientific Reports, 11
  • [50] Ring artifact correction for high-resolution micro CT
    Kyriakou, Yiannis
    Prell, Daniel
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (17): : N385 - N391