Simultaneous AFM and fluorescence imaging: A method for aligning an AFM-tip with an excitation beam using a 2D galvanometer

被引:5
|
作者
Moores, A. N. [1 ]
Cadby, A. J. [1 ]
机构
[1] Univ Sheffield, Dept Phys & Astron, Sheffield S3 7RH, S Yorkshire, England
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 02期
关键词
ATOMIC-FORCE MICROSCOPY; SUBNANOMETER-RESOLUTION;
D O I
10.1063/1.5006724
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Correlative fluorescence and atomic force microscopy (AFM) imaging is a highly attractive technique for use in biological imaging, enabling force and mechanical measurements of particular structures whose locations are known due to the specificity of fluorescence imaging. The ability to perform these two measurements simultaneously (rather than consecutively with post-processing correlation) is highly valuable because it would allow the mechanical properties of a structure to be tracked over time as changes in the sample occur. We present an instrument which allows simultaneous AFM and fluorescence imaging by aligning an incident fluorescence excitation beam with an AFM-tip. Alignment was performed by calibrating a 2D galvanometer present in the excitation beam path and using it to reposition the incident beam. Two programs were developed (one manual and one automated) which correlate sample features between the AFM and fluorescence images, calculating the distance required to translate the incident beam towards the AFM-tip. Using this method, we were able to obtain beam-tip alignment (and therefore field-of-view alignment) from an offset of > 15 mu m to within one micron in two iterations of the program. With the program running alongside data acquisition for real-time feedback between AFM and optical images, this offset was maintained over a time period of several hours. Not only does this eliminate the need to image large areas with both techniques to ensure that fields-of-view overlap, but it also raises the possibility of using this instrument for tip-enhanced fluorescence applications, a technique in which super-resolution images have previously been achieved. (C) 2018 Author(s).
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Study of negative hydrogen ion beam optics using the 2D PIC method
    Miyamoto, K.
    Okuda, S.
    Hatayama, A.
    Hanada, M.
    Kojima, A.
    THIRD INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2012), 2013, 1515 : 22 - 30
  • [22] Volumetric Imaging Using Fan-Beam Scanning with Reduced Redundancy 2D Arrays
    Wygant, Ira
    Karaman, Mustafa
    Oralkan, Oemer
    Khuri-Yakub, Butrus T.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2190 - +
  • [23] SOLUTION OF 2D CANTILEVER BEAM BY USING THE ELEMENT FREE GALERKIN METHOD WITH THE FINITE ELEMENT METHOD
    Pekedis, Mahmut
    Yildiz, Hasan
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2009, 27 (01): : 26 - 38
  • [24] Investigation on the spectral properties of 2D asynchronous fluorescence spectra generated by using variable excitation wavelengths as a perturbation
    Wang, Jingdan
    He, Anqi
    Guo, Ran
    Wei, Yongju
    Feng, Juan
    Xu, Yizhuang
    Noda, Isao
    Wu, Jinguang
    JOURNAL OF MOLECULAR STRUCTURE, 2016, 1124 : 221 - 227
  • [25] Study of 2D and 3D Optical Beam Induced Voltage Imaging Using Photoresistor Sensor
    Warsito, Wahyu Suciyati
    Susi, Harnani Akhmad Dzakwan
    MAKARA JOURNAL OF TECHNOLOGY, 2005, 9 (01): : 1 - 5
  • [26] Identification of olive pollen allergens using a fluorescence-based 2D multiplex method
    Zienkiewicz, Krzysztof
    de Dios Alche, Juan
    Zienkiewicz, Agnieszka
    Tormo, Alejandro
    Jesus Castro, Antonio
    ELECTROPHORESIS, 2015, 36 (7-8) : 1043 - 1050
  • [27] Body edge delineation in 2D DC resistivity imaging using differential method
    Susanto, Kusnahadi
    Bahari, Mohammad Fitrah
    PADJADJARAN EARTH DIALOGUES: INTERNATIONAL SYMPOSIUM ON GEOPHYSICAL ISSUES, PEDISGI, 2016, 29
  • [28] Evaluation of 2D Shear Wave Velocity Imaging of Subground Using HWAW Method
    Kim, Jong Tae
    Park, Hyung Choon
    Bang, Eun Seok
    Park, Heon Joon
    Kim, Dong Soo
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2007, 27 (02) : 105 - 114
  • [29] Method for Volume of Irregular Shape Pellets Estimation Using 2D Imaging Measurement
    Laucka, Andrius
    Andriukaitis, Darius
    Valinevicius, Algimantas
    Navikas, Dangirutis
    Zilys, Mindaugas
    Markevicius, Vytautas
    Klimenta, Dardan
    Sotner, Roman
    Jerabek, Jan
    APPLIED SCIENCES-BASEL, 2020, 10 (08):
  • [30] Accuracy of treatment position localization using 2D registration and cone beam CT imaging techniques
    Santanam, L.
    Esthappan, J.
    Thorstad, W. L.
    El Naqa, I.
    Drzymala, R.
    Hubenschmidt, J.
    Mutic, S.
    Goddu, S.
    Klein, E.
    Low, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S298 - S298