Cone-beam CT with a modified reverse helical trajectory for long object problem

被引:0
|
作者
Cho, Seungryong [1 ]
Xia, Dan [2 ]
Pelizzari, Charles A. [1 ]
Pan, Xiaochuam [2 ]
机构
[1] Univ Chicago, Dept Radiat Oncol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/NSSMIC.2007.4436887
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have applied two algorithms - chord-based backprojection-filtration (BPF) algorithm and Pack-Noo formula-based filtered-backprojection (FBP) algorithm - to reconstructing exact images from data acquired by a reverse helical CBCT. To achieve exact image reconstruction of a long object in a reverse helical CBCT, we have proposed an additional line scan with the chord-based algorithm. The added line scan yields additional chords that can completely fill the reconstructed the volume, thus avoiding the reconstruction gap when only a reverse helical trajectory is used. Numerical examples demonstrate the validity of the proposed method.
引用
收藏
页码:3518 / +
页数:2
相关论文
共 50 条
  • [41] Single-slice rebinning method for helical cone-beam CT
    Noo, F
    Defrise, M
    Clackdoyle, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02): : 561 - 570
  • [42] Katsevich-type reconstruction for dual helical cone-beam CT
    Zeng, Li
    Zou, Xiaobing
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (04) : 353 - 367
  • [43] A reconstruction algorithm for triple-source helical cone-beam CT
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1875 - 1878
  • [44] Physical phantom studies of helical cone-beam CT with exact reconstruction
    Tan, Jun
    Li, H. Harold
    Klein, Eric
    Li, Hua
    Parikh, Parag
    Yang, Deshan
    MEDICAL PHYSICS, 2012, 39 (08) : 4695 - 4704
  • [45] Sparse sampling in helical cone-beam CT perfect reconstruction algorithms
    Bendory, Tamir
    Feuer, Arie
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (03) : 389 - 405
  • [46] Simulation studies for triple-source helical cone-beam CT
    Zhao, Jun
    Jin, Yannan
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [47] High-contrast object localization and removal in cone-beam CT
    Moseley, DJ
    Siewerdsen, JH
    Jaffray, DA
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 40 - 50
  • [48] Dependence of cone-beam CT artifacts on the frequency content of the imaged object
    Jaffray, D
    Clackdoyle, R
    Siewerdsen, J
    Noo, F
    MEDICAL PHYSICS, 2003, 30 (06) : 1407 - 1407
  • [49] Cone-Beam Pair-Wise Data Consistency Conditions in Helical CT
    Mouchet, Melanie
    Letang, Jean Michel
    Lesaint, Jerome
    Rit, Simon
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (10) : 2853 - 2864
  • [50] Backprojection-filtration reconstruction for helical cone-beam CT with curved detectors
    Zuo, Nianming
    Xia, Dan
    Sidky, Emil Y.
    Yu, Lifeng
    Zou, Yu
    Pan, Xiaochuan
    Tang, Tianzi
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2306 - 2309