COMPARISON OF DIFFERENT PADC MATERIALS AND ETCHING CONDITIONS FOR FAST NEUTRON DOSIMETRY

被引:6
|
作者
Assenmacher, F. [1 ]
Boschung, M. [1 ]
Hohmann, E. [1 ]
Mayer, S. [1 ]
机构
[1] Paul Scherrer Inst, Div Radiat Safety & Secur, CH-5232 Villigen, Switzerland
关键词
DETECTORS; QUANTIFICATION;
D O I
10.1093/rpd/ncv421
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Etched-track polyallyl diglycol carbonate (PADC) dosemeters have been in use at the Paul Scherrer Institute since 1998 in neutron dosimetry for individual monitoring. In the last years, the availability of PADC materials from different manufacturers has grown, and different etching conditions were proposed, with the intention to improve the quality and overall performance of PADC in individual neutron monitoring. The goal of the present study was to compare the performance of different PADC materials and to investigate the influence of different etching conditions on sensitivity to fast neutrons and lower detection limit. The comparison covers six different PADC materials and eight different etching conditions.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 50 条
  • [31] Principal Component Analysis applied to neutron dosimetry based on PADC detectors and FNTDs
    Stabilini, A.
    Akselrod, M. S.
    Fomenko, V.
    Harrison, J.
    Yukihara, E. G.
    RADIATION MEASUREMENTS, 2021, 141
  • [32] A COUNTER FOR FAST NEUTRON DOSIMETRY
    MURTHY, KBS
    MUTHUKRISHNAN, G
    SUNTA, CM
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1967, 5 (01) : 26 - +
  • [33] Comparison of imaging plates with track detectors for fast-neutron dosimetry
    Belafrites, A
    Nourreddine, A
    Mouhssine, D
    Nachab, A
    Pape, A
    Boucenna, A
    Fernández, F
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 333 - 336
  • [34] Optically stimulated luminescence materials based on CaS for gamma and fast neutron dosimetry
    Hutt, G
    Jaek, I
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 297 - 300
  • [35] A COMPARISON OF THE RESPONSE OF PADC NEUTRON DOSEMETERS IN HIGH-ENERGY NEUTRON FIELDS
    Trompier, F.
    Boschung, M.
    Buffler, A.
    Domingo, C.
    Cale, E.
    Chevallier, M-A.
    Esposito, A.
    Ferrarini, M.
    Geduld, D. R.
    Hager, L.
    Hohmann, E.
    Mayer, S.
    Musso, A.
    Romero-Esposito, M.
    Roettger, S.
    Smit, F. D.
    Naik, A. Sashala
    Tanner, R.
    Wissmann, F.
    Caresana, M.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 78 - 81
  • [36] RECENT DEVELOPMENTS ON THE CRS PADC FAST-NEUTRON PERSONAL DOSIMETER
    DJEFFAL, S
    LOUNIS, Z
    ALLAB, M
    RADIATION PROTECTION DOSIMETRY, 1992, 44 (1-4) : 329 - 332
  • [37] INSTRUMENTATION DEVELOPMENTS IN FAST NEUTRON DOSIMETRY
    HURST, GS
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1953, 41 (03): : 421 - 421
  • [38] FAST NEUTRON DOSIMETRY IN PILE IRRADIATIONS
    HOUSTON, RW
    NUCLEAR SCIENCE AND ENGINEERING, 1958, 4 (02) : 227 - 238
  • [39] INFLUENCE OF VARIATION OF ETCHING CONDITIONS ON THE SENSITIVITY OF PADC DETECTORS WITH A NEW EVALUATION METHOD
    Fiechtner-Scharrer, A.
    Mayer, S.
    Boschung, M.
    Whitelaw, A.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 150 - 154
  • [40] THERMAL-NEUTRON DOSIMETRY USING ELECTROCHEMICAL ETCHING
    SU, SJ
    SANDERS, M
    MORGAN, KZ
    HEALTH PHYSICS, 1979, 37 (06): : 796 - 796