COMPARISON OF DIFFERENT PADC MATERIALS AND ETCHING CONDITIONS FOR FAST NEUTRON DOSIMETRY

被引:6
|
作者
Assenmacher, F. [1 ]
Boschung, M. [1 ]
Hohmann, E. [1 ]
Mayer, S. [1 ]
机构
[1] Paul Scherrer Inst, Div Radiat Safety & Secur, CH-5232 Villigen, Switzerland
关键词
DETECTORS; QUANTIFICATION;
D O I
10.1093/rpd/ncv421
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Etched-track polyallyl diglycol carbonate (PADC) dosemeters have been in use at the Paul Scherrer Institute since 1998 in neutron dosimetry for individual monitoring. In the last years, the availability of PADC materials from different manufacturers has grown, and different etching conditions were proposed, with the intention to improve the quality and overall performance of PADC in individual neutron monitoring. The goal of the present study was to compare the performance of different PADC materials and to investigate the influence of different etching conditions on sensitivity to fast neutrons and lower detection limit. The comparison covers six different PADC materials and eight different etching conditions.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 50 条
  • [1] COMPARISON OF DIFFERENT PADC MATERIALS FOR NEUTRON DOSIMETRY
    Mayer, S.
    Boschung, M.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 104 - 107
  • [2] The acceptance testing of PADC detectors for fast neutron dosimetry using PuBe neutron source
    Filova, Vendula
    Vrban, Branislav
    Blahusiak, Pavol
    Luley, Jakub
    Cerba, Stefan
    Necas, Vladimir
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [3] The new PADC based fast neutron dosimetry system of the INFN-LNF
    Bedogni, R.
    Esposito, A.
    Lovestam, G.
    Garcia, M. J.
    Virgolici, M.
    RADIATION MEASUREMENTS, 2008, 43 : S491 - S494
  • [4] COMPARISON OF PADC NEUTRON DETECTORS FROM DIFFERENT SUPPLIERS
    Caresana, M.
    Parravicini, A.
    Coria, S.
    Stabilini, A.
    Assenmacher, F.
    Yukihara, E. G.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 196 - 200
  • [5] THE NRPB PADC NEUTRON PERSONAL DOSIMETRY SERVICE
    GILVIN, PJ
    BARTLETT, DT
    STEELE, JD
    RADIATION PROTECTION DOSIMETRY, 1987, 20 (1-2) : 99 - 102
  • [6] The NRPB PADC neutron personal dosimetry service
    Gilvin, PJ
    Bartlett, DT
    Shaw, PV
    Steele, JD
    Tanner, RJ
    RADIATION PROTECTION DOSIMETRY, 2001, 96 (1-3) : 191 - 195
  • [7] Inter-comparison among fast neutron dosimetric services using PADC material of different composition
    Fantuzzi, E
    Boschung, M
    Fiechtner, A
    Hoffmann, J
    McKeever, R
    Stokes, R
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 487 - 492
  • [8] STUDY OF THE ANGLE RESPONSE OF VARIOUS PADC MATERIALS AT DIFFERENT NEUTRON ENERGIES
    AZIMIGARAKANI, D
    WERNLI, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 72 (01): : 79 - 83
  • [9] FAST-NEUTRON DOSIMETRY WITH CR-36 - STUDY OF VARIOUS MATERIALS USING ELECTROCHEMICAL ETCHING
    ALBERTS, WG
    LUSZIKBHADRA, M
    PIESCH, E
    VILGIS, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 437 - 442
  • [10] NEW ETCHING CONDITIONS FOR CR-39 FOR NEUTRON DOSIMETRY
    AZIMIGARAKANI, D
    BOSCHUNG, M
    WERNLI, C
    RADIATION PROTECTION DOSIMETRY, 1991, 35 (02) : 93 - 98