Effect of the thermal insulation on generator and micro gas turbine system

被引:19
|
作者
Park, Jun Su [1 ]
Park, Sehjin [1 ]
Kim, Kyung Min [2 ]
Choi, Beom Seok [3 ]
Cho, Hyung Hee [1 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul 120749, South Korea
[2] Korea Dist Heating Corp, Seoul 135220, South Korea
[3] Korea Inst Machinery & Mat, Taejon 303343, South Korea
关键词
Micro gas turbine; Generator; Conjugate heat transfer; Thermal analysis; HEAT-TRANSFER; TEMPERATURE;
D O I
10.1016/j.energy.2013.07.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
The efficiency of micro gas turbine generator is affected significantly by the temperature level in the micro gas turbine system. If the operation temperature of generator and compressor increases, the efficiency of generator and compressor decreases, greatly. This study investigates the heat transfer and temperature distribution in a micro gas turbine system. In addition, the temperature levels on the substrates are controlled using the different thermal insulation materials. The thermal conductivity of insulation is changed from 0.1 to 100 to evaluate the effect of the thermal conductivity on generator and micro gas turbine. A conjugate heat transfer method has been used for this purpose. We conducted a CFD analysis in the compressor and turbine flow domains using CFX v.12 to obtain the boundary conditions for conduction calculation. The conduction analysis, using ANSYS v.12, was calculated on the solid part domain. The conduction heat transfer calculation considered the heat generation induced by the joule heating in the generator. The results show that the most heat flux from the turbine and generator is removed by the inlet flow induced by the compressor. The conductivity of thermal insulation material has a little effect on the temperature distributions of the generator. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:581 / 589
页数:9
相关论文
共 50 条
  • [41] A Short Review on the Offshore Wind Turbine Generator Windings' Insulation and the Effect of Water Droplets and Salinity
    Malliou, Christina-Panagiota
    Karlis, Athanasios D.
    Danikas, Michael G.
    Lloyd, Blake
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (06) : 4610 - 4618
  • [42] Landfill low emission micro turbine generator
    Stefanakos, EK
    Krakow, B
    Moore, G
    Todd, E
    Pasley, A
    Cascio, J
    Denham, A
    Proceedings of the Fourth IASTED International Conference on Power and Energy Systems, 2004, : 52 - 56
  • [43] Assessment of 300MW Turbine Generator Stator Insulation
    Wang, Lijun
    Zhang, Yizhong
    Jin, Wenjing
    Shi, Jingzhe
    Zhou, Song
    Li, Qiang
    Liu, Song
    PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, : 500 - 502
  • [44] Evaluating the Effect of Syngas Composition on Micro gas turbine Performance
    Fareeza, N.
    Tan, E. S.
    Kumaran, P.
    Indra, T. M.
    Fadzilah, N.
    Yoshikawa, K.
    INTERNATIONAL CONFERENCE ON ADVANCES IN RENEWABLE ENERGY AND TECHNOLOGIES (ICARET 2016), 2016, 32
  • [45] REASSESSMENT OF THE ELECTRICAL REQUIREMENTS OF LARGE TURBINE GENERATOR INSULATION.
    Botts, J.C.
    Baldwin, M.S.
    1979,
  • [46] DISCHARGE STUDIES OF EPOXY-MICA TURBINE GENERATOR INSULATION
    WOOD, JW
    RYDER, DM
    HOGG, WK
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (05): : 1531 - 1537
  • [47] Micro thermal power generator
    Miyazaki, Koji
    IEEJ Transactions on Sensors and Micromachines, 2013, 133 (09) : 237 - 241
  • [48] EFFECT OF TURBINE-GENERATOR REPRESENTATION IN SYSTEM STABILITY STUDIES
    LOKAY, HE
    BOLGER, RL
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (10): : 933 - &
  • [49] THERMAL INSULATION OFFERS TURBO TURBINE BENEFITS
    Motor Ship, 2021, 102 (1189): : 36 - 37
  • [50] Position sensorless starting of super high-speed PM generator for micro gas turbine
    Morimoto, M
    Aiba, K
    Sakurai, T
    Hoshino, A
    Fujiwara, M
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (02) : 415 - 420