Aortic Valve Area on 64-MDCT Correlates with Transesophageal Echocardiography in Aortic Stenosis

被引:30
|
作者
LaBounty, Troy M. [1 ]
Sundaram, Baskaran [2 ]
Agarwal, Prachi [2 ]
Armstrong, William A. [1 ]
Kazerooni, Ella A. [2 ]
Yamada, Elina [1 ]
机构
[1] Univ Michigan, Ctr Cardiovasc, Dept Internal Med, Div Cardiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Ctr Cardiovasc, Dept Radiol, Div Cardiothorac Radiol, Ann Arbor, MI 48109 USA
关键词
aortic valve; aortic valve stenosis; CT; transesophageal echocardiography;
D O I
10.2214/AJR.07.3703
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to compare aortic valve area and calcification between CT and echocardiography. MATERIALS AND METHODS. We performed retrospective evaluation of 80 consecutive patients with aortic stenosis (AS) who underwent ECG-gated 64-MDCT and transesophageal echocardiography (TEE). Valve planimetry was feasible in 80 patients with CT and in 63 patients with TEE; valve area by transthoracic echocardiography was available in 46 patients. Valve calcification grade on CT was compared with TEE. One cardiologist (echocardiography) and two radiologists (CT) independently and blindly reviewed the studies. Pearson's correlations, Spearman's rank correlations, paired Student's t tests, and weighted kappa tests were used. RESULTS. The median valve area on TEE was 0.7 +/- 0.9 cm(2). There was excellent correlation (n = 80; r = 0.91, p < 0.001) and no difference (0.06 +/- 0.26 cm2, p = 0.06) between CT readers. There was strong correlation (n = 63; r = 0.84, p < 0.001) and no difference (-0.06 +/- 0.48 cm(2), p = 0.33) in valve area between CT and TEE, with a strong correlation (n = 46; r = 0.83, p < 0.001) and small overestimation (0.17 +/- 0.33 cm(2), p < 0.001) in valve area with CT versus transthoracic echocardiography. The sensitivity and specificity of CT to detect severe aortic stenosis compared with TEE were 92.1% (35/38) and 89.5% (17/19), respectively. Calcification grade had fair agreement between CT readers and TEE (kappa = 0.34 and 0.37, respectively). CONCLUSION. Aortic valve area on CT strongly correlates with echocardiography and has excellent sensitivity and specificity to detect severe stenosis. Valve calcification has fair agreement between studies. Valve area and calcification should be reported on CT angiography in patients with AS.
引用
收藏
页码:1652 / 1658
页数:7
相关论文
共 50 条
  • [31] NONINVASIVE QUANTIFICATION OF THE AORTIC-VALVE AREA IN AORTIC-STENOSIS BY DOPPLER ECHOCARDIOGRAPHY
    ZHANG, Y
    MYHRE, E
    NITTERHAUGE, S
    EUROPEAN HEART JOURNAL, 1985, 6 (12) : 992 - 998
  • [32] NONINVASIVE QUANTIFICATION OF AORTIC-VALVE AREA IN AORTIC-STENOSIS BY DOPPLER ECHOCARDIOGRAPHY
    ZHANG, Y
    NITTERHAUGE, S
    MYHRE, E
    CIRCULATION, 1985, 72 (04) : 144 - 144
  • [33] THREE-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY MEASUREMENT OF AORTIC VALVE SURFACE COAPTATION INDEXED TO THE ANNULAR AREA CORRELATES WITH SEVERITY OF AORTIC INSUFFICIENCY
    Song, M. S.
    Cappadona, J.
    Nasr, V.
    Cobey, F.
    ANESTHESIA AND ANALGESIA, 2013, 116 : 66 - 66
  • [34] Right Aortic Arch with Kommerell's Diverticulum Using 64-MDCT
    Shiga, Yuhei
    Miura, Shin-ichiro
    Hitaka, Yuka
    Saku, Keijiro
    INTERNAL MEDICINE, 2012, 51 (11) : 1437 - 1438
  • [35] Quadricuspid aortic valve diagnosed by transesophageal echocardiography
    Georgeson, S
    Neibart, RM
    AMERICAN HEART JOURNAL, 1996, 132 (06) : 1292 - 1293
  • [36] Aortic Valve Anatomy and Assessment by Transesophageal Echocardiography
    Roberts, Joseph Devin
    Dhawan, Richa
    Chaney, Mark A.
    Lang, Roberto M.
    ANESTHESIA AND ANALGESIA, 2013, 117 (06): : 1286 - 1290
  • [37] TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR TRANSCATHETER AORTIC VALVE REPLACEMENT
    Lerakis, S.
    Block, P.
    Thourani, V.
    Guyton, R.
    Babaliaros, V.
    CARDIOLOGY, 2013, 125 : 238 - 238
  • [38] Transesophageal Echocardiography for Tricuspid Aortic Valve Repair
    Kim, Thomas Y.
    Alfirevic, Andrej
    Wallace, Lee K.
    ANESTHESIA AND ANALGESIA, 2010, 110 (02): : 370 - 372
  • [39] Amounts of Aortic Atherosclerosis in Patients With Aortic Stenosis as Determined by Transesophageal Echocardiography
    Osranek, Martin
    Pilip, Adelbert
    Patel, Paragh R.
    Molisse, Theresa
    Tunick, Paul A.
    Kronzon, Itzhak
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (05): : 713 - 717
  • [40] Simultaneous determination of aortic valve area by the gorlin formula and by transesophageal echocardiography under different transvalvular flow conditions - Evidence that anatomic aortic valve area does not change with variations in flow in aortic stenosis
    Tardif, JC
    Rodrigues, AG
    Hardy, JF
    Leclerc, Y
    Petitclerc, R
    Mongrain, R
    Mercier, LA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (06) : 1296 - 1302