Amperometric glucose biosensor based on layer-by-layer covalent attachment of AMWNTs and IO4--oxidized GOx

被引:43
|
作者
Sun, Yingying [1 ]
Wang, Haiying [1 ]
Sun, Changqing [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130012, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2008年 / 24卷 / 01期
关键词
amino terminated carbon nanotubes; layer-by-layer covalent attachment; low-potential detection of the glucose; glucose biosensors;
D O I
10.1016/j.bios.2008.03.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Multi-wall carbon nanotubes (MWNTs) functionalized with amino groups were prepared via silane treatment using 3-aminopropyltrimethoxysilane (APS) as a silane-coupling agent. The resultant amino terminated MWNTs (AMWNTs) were applied to construct glucose biosensors with IO4--oxidized glucose oxidase (IO4--oxidized GOx) through the layer-by-layer (LBL) covalent self-assembly method without any cross-linker. Scanning electron microscopy (SEM) indicated that the assembled AMWNTs were almost in a form of small bundles or single nanotubes, and the surface density increased uniformly with the number of GOx/AMWNTs bilayers, From the analysis of voltammetric signals, a linear increment of the coverage of GOx per bilayer was estimated. The resulting biosensor showed excellent catalytic activity towards the electroreduction of dissolved oxygen at low overvoltage, based on which glucose concentration was monitored conveniently. The enzyme electrode exhibited good electrocatalytic response towards the glucose and that response increased with the number of GOx/AMWNTs bilayers, suggesting that the analytical performance such as sensitivity and detection limit of the glucose biosensors could be tuned to the desired level by adjusting the number of deposited GOx/AMWNTs bilayers. The biosensor constructed with four bilayers of GOx/AMWNTs showed high sensitivity of 7.46 mu A mM(-1) cm(-2) and the detection limit of 8.0 mu M, with a fast response less than 10 s. Because of relative low applied potential, the interference from other electro-oxidizable compounds was minimized, which improved the selectivity of the biosensors. Furthermore, the obtained enzyme electrodes also showed remarkable stability due to the covalent interaction between the GOx and AMWNTs. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:22 / 28
页数:7
相关论文
共 50 条
  • [41] Amperometric hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase (HRP) on the layer-by-layer assembly films of gold colloidal nanoparticles and toluidine blue
    Chen, SH
    Yuan, R
    Chai, YQ
    Xu, L
    Wang, N
    Li, XN
    Zhang, LY
    ELECTROANALYSIS, 2006, 18 (05) : 471 - 477
  • [42] Amperometric Choline Biosensor Based on Dispersion of Multi-walled Carbon Nanotubes in Poly(diallyldimethylammonium chloride) via Layer-by-Layer Assembly Technique
    Chen Li-Li
    Wang Hui-Cai
    Qin Xia
    Wang Xin-Sheng
    Zhao Zi-Xia
    Miao Zhi-Ying
    Zhao Wei
    Shan Miao-Miao
    Chen Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (03) : 337 - 341
  • [43] A new self-assembled layer-by-layer glucose biosensor based on chitosan biopolymer entrapped enzyme with nitrogen doped graphene
    Barsan, Madalina M.
    David, Melinda
    Florescu, Monica
    Tugulea, Laura
    Brett, Christopher M. A.
    BIOELECTROCHEMISTRY, 2014, 99 : 46 - 52
  • [44] A novel amperometric glucose biosensor based on reconstitution of glucose oxidase on thiophene-3-boronic acid polymer layer
    Senel, Mehmet
    Dervisevic, Muamer
    Cevik, Emre
    CURRENT APPLIED PHYSICS, 2013, 13 (07) : 1199 - 1204
  • [45] A sensitive and stable biosensor based on the direct electrochemistry of glucose oxidase assembled layer-by-layer at the multiwall carbon nanotube-modified electrode
    Deng, Chunyan
    Chen, Jinhua
    Nie, Zhou
    Si, Shihui
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (01): : 213 - 219
  • [46] Novel biosensor receptor based on multilayer-enzyme membrane via layer-by-layer assembly of sol-gel and glucose oxidase
    Huang, Jiadong
    Ge, Lei
    LUMINESCENCE, 2010, 25 (02) : 97 - 97
  • [47] Amperometric detection of glucose in fruit juices with polypyrrole-based biosensor with an integrated permselective layer for exclusion of interferences
    Ayenimo, Joseph G.
    Adeloju, Samuel B.
    FOOD CHEMISTRY, 2017, 229 : 127 - 135
  • [48] Oxygen insensitive amperometric glucose biosensor based on FAD dependent glucose dehydrogenase co-entrapped with DCPIP or DCNQ in a polydopamine layer
    Cohen, Roy
    Cohen, Yifat
    Mukha, Dina
    Yehezkeli, Omer
    ELECTROCHIMICA ACTA, 2021, 367
  • [49] Highly stretchable, adhesive and conductive hydrogel for flexible and stable bioelectrocatalytic sensing layer of enzyme-based amperometric glucose biosensor
    Tang, Linghui
    Huang, Yufeng
    Wang, Yue
    Zhao, Jifan
    Lian, Huiyong
    Dong, Yan
    Zhang, Zhiqiang
    Hasebe, Yasushi
    BIOELECTROCHEMISTRY, 2025, 163
  • [50] A "signal on" photoelectrochemical biosensor for miRNA-21 detection based on layer-by-layer assembled n-n type Bi2S3@CdIn2S4 heterojunction
    Cui, Ya Bin
    Sun, Zhe
    Qing, Min
    Yu, Ling Dan
    Yan, Hang
    Luo, Hong Qun
    Li, Nian Bing
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 373