Amperometric glucose biosensor based on layer-by-layer covalent attachment of AMWNTs and IO4--oxidized GOx

被引:43
|
作者
Sun, Yingying [1 ]
Wang, Haiying [1 ]
Sun, Changqing [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130012, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2008年 / 24卷 / 01期
关键词
amino terminated carbon nanotubes; layer-by-layer covalent attachment; low-potential detection of the glucose; glucose biosensors;
D O I
10.1016/j.bios.2008.03.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Multi-wall carbon nanotubes (MWNTs) functionalized with amino groups were prepared via silane treatment using 3-aminopropyltrimethoxysilane (APS) as a silane-coupling agent. The resultant amino terminated MWNTs (AMWNTs) were applied to construct glucose biosensors with IO4--oxidized glucose oxidase (IO4--oxidized GOx) through the layer-by-layer (LBL) covalent self-assembly method without any cross-linker. Scanning electron microscopy (SEM) indicated that the assembled AMWNTs were almost in a form of small bundles or single nanotubes, and the surface density increased uniformly with the number of GOx/AMWNTs bilayers, From the analysis of voltammetric signals, a linear increment of the coverage of GOx per bilayer was estimated. The resulting biosensor showed excellent catalytic activity towards the electroreduction of dissolved oxygen at low overvoltage, based on which glucose concentration was monitored conveniently. The enzyme electrode exhibited good electrocatalytic response towards the glucose and that response increased with the number of GOx/AMWNTs bilayers, suggesting that the analytical performance such as sensitivity and detection limit of the glucose biosensors could be tuned to the desired level by adjusting the number of deposited GOx/AMWNTs bilayers. The biosensor constructed with four bilayers of GOx/AMWNTs showed high sensitivity of 7.46 mu A mM(-1) cm(-2) and the detection limit of 8.0 mu M, with a fast response less than 10 s. Because of relative low applied potential, the interference from other electro-oxidizable compounds was minimized, which improved the selectivity of the biosensors. Furthermore, the obtained enzyme electrodes also showed remarkable stability due to the covalent interaction between the GOx and AMWNTs. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:22 / 28
页数:7
相关论文
共 50 条
  • [1] Amperometric Glucose Biosensor Based on Layer-by-layer Covalent Attachment of ASNPs and GOx
    Sun, Ying Ying
    Wang, Jie
    Ren, Qun Xiang
    Qin, Yan
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY V, 2015, : 776 - 780
  • [2] An amperometric glucose biosensor based on layer-by-layer GOx-SWCNT conjugate/redox polymer multilayer on a screen-printed carbon electrode
    Gao, Qiang
    Guo, Yanyan
    Zhang, Wenyan
    Qi, Honglan
    Zhang, Chengxiao
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01): : 219 - 225
  • [3] Multilayered construction of glucose oxidase on gold electrodes based on layer-by-layer covalent attachment
    Zhang, SX
    Yang, WW
    Niu, YM
    Sun, CQ
    ANALYTICA CHIMICA ACTA, 2004, 523 (02) : 209 - 217
  • [4] Construction of Amperometric Glucose Sensor using Carbon Nanotubes and IO4-oxidized GOx
    Sun, YingYing
    Wang, Jie
    Ge, Xin
    MANUFACTURING CONSTRUCTION AND ENERGY ENGINEERING: 2016 INTERNATIONAL CONFERENCE ON MANUFACTURING CONSTRUCTION AND ENERGY ENGINEERING, 2016, : 249 - 252
  • [5] Amperometric glucose biosensor based on layer-by-layer films of microperoxidase-11 and liposome-encapsulated glucose oxidase
    Graca, J. S.
    de Oliveira, R. F.
    de Moraes, M. L.
    Ferreira, M.
    BIOELECTROCHEMISTRY, 2014, 96 : 37 - 42
  • [6] Multilayered construction of glucose oxidase and silica nanoparticles on Au electrodes based on layer-by-layer covalent attachment
    Sun, YY
    Yan, F
    Yang, WS
    Sun, CQ
    BIOMATERIALS, 2006, 27 (21) : 4042 - 4049
  • [7] Multilayered construction of glucose oxidase and gold nanoparticles on Au electrodes based on layer-by-layer covalent attachment
    Yang, WW
    Wang, JX
    Zhao, S
    Sun, YY
    Sun, CQ
    ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (04) : 665 - 672
  • [8] An amperometric glucose biosensor based on electrostatic force induced layer-by-layer GOD/chitosan/pyrite on a glassy carbon electrode
    Tingting Ma
    Yue Wang
    Ying Hou
    Enlei Wang
    Guoqing Yin
    Yasushi Hasebe
    Zhiqiang Zhang
    Analytical Sciences, 2022, 38 : 553 - 562
  • [9] An amperometric glucose biosensor based on electrostatic force induced layer-by-layer GOD/chitosan/pyrite on a glassy carbon electrode
    Ma, Tingting
    Wang, Yue
    Hou, Ying
    Wang, Enlei
    Yin, Guoqing
    Hasebe, Yasushi
    Zhang, Zhiqiang
    ANALYTICAL SCIENCES, 2022, 38 (03) : 553 - 562
  • [10] A novel, ultra sensible biosensor built by layer-by-layer covalent attachment of a receptor for diagnosis of tumor growth
    Uygun, Zihni Onur
    Sezginturk, Mustafa Kemal
    ANALYTICA CHIMICA ACTA, 2011, 706 (02) : 343 - 348