Noise-Induced Change of Cortical Temporal Processing in Cochlear Implant Users

被引:9
|
作者
Han, Ji-Hye [1 ]
Lee, Jihyun [1 ]
Lee, Hyo-Jeong [1 ,2 ]
机构
[1] Lab Brain & Cognit Sci Convergence Med, Anyang, Peoples R China
[2] Hallym Univ, Dept Otorhinolaryngol Head & Neck Surg, Coll Med, 1 Hallimdaehak Gil, Chuncheon 24252, Peoples R China
基金
新加坡国家研究基金会;
关键词
Cochlear Implant; Noise-Induced; Auditory Evoked Potentials; Voice Onset Time; HEARING-LOSS; SPEECH; PERCEPTION; POTENTIALS; RESPONSES; SIGNALS; AGE;
D O I
10.21053/ceo.2019.01081
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives. Cochlear implant (CI) users typically report impaired ability to understand speech in noise. Speech understanding in CI users decreases with noise due to reduced temporal processing ability, and speech perceptual errors involve stop consonants distinguished by voice onset time (VOT). The current study examined the effects of noise on various speech perception tests while at the same time used cortical auditory evoked potentials (CAEPs) to quantify the change of neural processing of speech sounds caused by noise. We hypothesized that the noise effects on VOT processing can be reflected in N1/P2 measures, the neural changes relate to behavioral speech perception performances. Methods. Ten adult CI users and 15 normal-hearing (NH) people participated in this study. CAEPs were recorded from 64 scalp electrodes in both quiet and noise (signal-to-noise ratio +5 dB) and in passive and active (requiring consonant discrimination) listening. Speech stimulus was synthesized consonant-vowels with VOTs of 0 and 50 ins. N1-P2 amplitudes and latencies were analyzed as a function of listening condition. For the active condition, the P3b also was analyzed. Behavioral measures included a variety of speech perception tasks. Results. For good performing CI users, performance in most speech test was lower in the presence of noise masking. N1 and P2 latencies became prolonged with noise masking. The P3b amplitudes were smaller in CI groups compared to NH. The degree of P2 latency change (0 vs. 50 msVOT) was correlated with consonant perception in noise. Conclusion. The effects of noise masking on temporal processing can be reflected in cortical responses in CI users. N1/P2 latencies were more sensitive to noise masking than amplitude measures. Additionally, P2 responses appear to have a better relationship to speech perception in CI users compared to N1.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 50 条
  • [31] Speech Recognition and Temporal Amplitude Modulation Processing by Mandarin-Speaking Cochlear Implant Users
    Luo, Xin
    Fu, Qian-Jie
    Wei, Chao-Gang
    Cao, Ke-Li
    EAR AND HEARING, 2008, 29 (06): : 957 - 970
  • [32] Within- and across-frequency temporal processing and speech perception in cochlear implant users
    Blankenship, Chelsea M.
    Meinzen-Derr, Jareen
    Zhang, Fawen
    PLOS ONE, 2022, 17 (10):
  • [33] Perception of Iterated Rippled Noise Periodicity in Cochlear Implant Users
    Wagner, Luise
    Plontke, Stefan K.
    Rahne, Torsten
    AUDIOLOGY AND NEURO-OTOLOGY, 2017, 22 (02) : 104 - 115
  • [34] Benefit of the UltraZoom beamforming technology in noise in cochlear implant users
    Isabelle Mosnier
    Nathalie Mathias
    Jonathan Flament
    Dorith Amar
    Amelie Liagre-Callies
    Stephanie Borel
    Emmanuèle Ambert-Dahan
    Olivier Sterkers
    Daniele Bernardeschi
    European Archives of Oto-Rhino-Laryngology, 2017, 274 : 3335 - 3342
  • [35] Benefit of the UltraZoom beamforming technology in noise in cochlear implant users
    Mosnier, Isabelle
    Mathias, Nathalie
    Flament, Jonathan
    Amar, Dorith
    Liagre-Callies, Amelie
    Borel, Stephanie
    Ambert-Dahan, Emmanuele
    Sterkers, Olivier
    Bernardeschi, Daniele
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (09) : 3335 - 3342
  • [36] TEMPORAL PROCESSING IN NOISE BY PERSONS WITH NOISE-INDUCED AND AGE-RELATED HEARING-LOSS
    CUDAHY, EA
    ELLIOTT, LL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1975, 58 : S71 - S71
  • [37] Evaluation of a transient noise reduction algorithm in cochlear implant users
    Dyballa, Karl-Heinz
    Hehrmann, Phillipp
    Hamacher, Volkmar
    Nogueira, Waldo
    Lenarz, Thomas
    Buechner, Andreas
    AUDIOLOGY RESEARCH, 2015, 5 (02)
  • [38] Temporal characteristics of stop consonants in pediatric cochlear implant users
    Joy, Deepthy Ann
    Sreedevi, N.
    COCHLEAR IMPLANTS INTERNATIONAL, 2019, 20 (05) : 242 - 249
  • [39] Commentary on the regulatory implications of noise-induced cochlear neuropathy
    Dobie, Robert A.
    Humes, Larry E.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2017, 56 : 74 - 78
  • [40] Cochlear Synaptopathy and Noise-Induced Hidden Hearing Loss
    Shi, Lijuan
    Chang, Ying
    Li, Xiaowei
    Aiken, Steve
    Liu, Lijie
    Wang, Jian
    NEURAL PLASTICITY, 2016, 2016