Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: An intra-individual comparison

被引:38
|
作者
Lee, Seung Hyun [1 ,2 ]
Kim, Myung-Joon [1 ,2 ]
Yoon, Choon-Sik [3 ]
Lee, Mi-Jung [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Severance Childrens Hosp, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Severance Childrens Hosp, Seoul 120752, South Korea
[3] Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 120752, South Korea
关键词
Adaptive statistical iterative reconstruction; Image quality; Radiation dose; Reconstruction algorithm; CT; TUBE CURRENT MODULATION; IMPROVED IMAGE QUALITY; COMPUTED-TOMOGRAPHY; FEASIBILITY; EXPERIENCE; ALGORITHM; EXPOSURE;
D O I
10.1016/j.ejrad.2012.06.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To retrospectively compare radiation dose and image quality of pediatric chest CT using a routine dose protocol reconstructed with filtered back projection (FBP) (the Routine study) and a low-dose protocol with 50% adaptive statistical iterative reconstruction (ASIR) (the ASIR study). Materials and methods: We retrospectively reviewed chest CT performed in pediatric patients who underwent both the Routine study and the ASIR study on different days between January 2010 and August 2011. Volume CT dose indices (CTDIvol), dose length products (DLP), and effective doses were obtained to estimate radiation dose. The image quality was evaluated objectively as noise measured in the descending aorta and paraspinal muscle, and subjectively by three radiologists for noise, sharpness, artifacts, and diagnostic acceptability using a four-point scale. The paired Student's t-test and the Wilcoxon signed-rank test were used for statistical analysis. Results: Twenty-six patients (M: F = 13: 13, mean age 11.7) were enrolled. The ASIR studies showed 60.3%, 56.2%, and 55.2% reductions in CTDIvol (from 18.73 to 7.43 mGy, P < 0.001), DLP (from 307.42 to 134.51 mGy x cm, P < 0.001), and effective dose (from 4.12 to 1.84 mSv, P < 0.001), respectively, compared with the Routine studies. The objective noise was higher in the paraspinal muscle of the ASIR studies (20.81 vs. 16.67, P = 0.004), but was not different in the aorta (18.23 vs. 18.72, P = 0.726). The subjective image quality demonstrated no difference between the two studies. Conclusion: A low-dose protocol with 50% ASIR allows radiation dose reduction in pediatric chest CT by more than 55% while maintaining image quality. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E938 / E943
页数:6
相关论文
共 50 条
  • [41] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    Notohamiprodjo, S.
    Deak, Z.
    Meurer, F.
    Maertz, F.
    Mueck, F. G.
    Geyer, L. L.
    Wirth, S.
    EUROPEAN RADIOLOGY, 2015, 25 (01) : 140 - 146
  • [42] Prediction of Volume CT Dose Index for Dose Modulation with Adaptive Statistical Iterative Reconstruction -V (ASIR-V)
    Zhou, Y. Jimmy
    Nute, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E240 - E240
  • [43] Value of using adaptive statistical iterative reconstruction-V (ASIR-V) technology in pediatric head CT dose reduction
    Fatma Mohamed Sherif
    Ayman Mokhtar Said
    Yara Nagi Elsayed
    Sabry Alameldeen Elmogy
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [44] Reducing dose in SPECT/CT using adaptive statistical iterative reconstruction technique
    Choi, Jinwook
    Choi, Hyeonjun
    Park, Chan Rok
    Cho, Sung Wook
    Kim, Jin Eui
    Lee, Jae Sung
    Lee, Dong Soo
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [45] Quantitative evaluation of ASiR image quality: An adaptive statistical iterative reconstruction technique
    Van de Casteele, Elke
    Parizel, Paul
    Sijbers, Jan
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [46] Value of using adaptive statistical iterative reconstruction-V (ASIR-V) technology in pediatric head CT dose reduction
    Sherif, Fatma Mohamed
    Said, Ayman Mokhtar
    Elsayed, Yara Nagi
    Elmogy, Sabry Alameldeen
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01):
  • [47] Assessment of noise reduction potential and image quality improvement of a new generation adaptive statistical iterative reconstruction (ASIR-V) in chest CT
    Tang, Hui
    Yu, Nan
    Jia, Yongjun
    Yu, Yong
    Duan, Haifeng
    Han, Dong
    Ma, Guangming
    Ren, Chenglong
    He, Taiping
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1081):
  • [48] Image Quality in Children with Low-Radiation Chest CT Using Adaptive Statistical Iterative Reconstruction and Model-Based Iterative Reconstruction
    Sun, Jihang
    Peng, Yun
    Duan, Xiaomin
    Yu, Tong
    Zhang, Qifeng
    Liu, Yong
    Hu, Di
    PLOS ONE, 2014, 9 (05):
  • [49] Evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction with the same group of patients
    Qi, L-P
    Li, Y.
    Tang, L.
    Li, Y-L
    Li, X-T
    Cui, Y.
    Sun, Y-S
    Zhang, X-P
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018): : E906 - E911
  • [50] New adaptive statistical iterative reconstruction ASiR-V: Assessment of noise performance in comparison to ASiR
    De Marco, Paolo
    Origgi, Daniela
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 275 - 286