Liquid Chromatographic Method Development for Quantification of Inorganic Nitrite and Nitrate Impurities from Nitroglycerin Drug Substance by Using Ion-Pair Reagents with Liquid-Liquid Extraction Technique

被引:2
|
作者
Desai, Pritesh R. [1 ]
Mehta, Priti J. [1 ]
Chokshi, Avani B. [2 ]
机构
[1] Nirma Univ, Inst Pharm, Ahmadabad 382481, Gujarat, India
[2] CHARUSAT, Ramanbhai Patel Coll Pharm, Changa 388421, Gujarat, India
关键词
DINITRATE METABOLITES; GAS-CHROMATOGRAPHY; MASS SPECTROMETRY; SAMPLES; URINE; BLOOD;
D O I
10.1093/chromsci/bmz102
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A large number of laboratory studies have reported Nitrite (NO2-) and Nitrate (NO3-) to be among the most common degradation products of the high-explosive Nitroglycerin drug substance. A novel, simple, robust and rapid reversed-phase high-performance liquid chromatography method has been developed for quantification of inorganic Nitrite and Nitrate impurities from Nitroglycerin drug substance. Successful separation was achieved in isocratic elution, using lnertsil C8-3, (250 x 4.6 mm, 5.0 mu m) column, with mobile phase consisting of pH 7.0 tetrabutyl ammonium hydrogen sulfate buffer, methanol and acetonitrile (96:02:02, v/v/v). Flow rate was monitored at 2.0 mL min(-1) and ultraviolet detection at 220 nm. The present work describes the role of an ion-pair reagent in the separation of polar compounds and liquid-liquid extraction technique for separation of polar and non-polar compounds. Nitroglycerin was subjected to various stress conditions to demonstrate the stability-indicating power of the method. The performance of the method was validated as per present International Council for Harmonisation (ICH) guidelines for specificity, linearity, accuracy, precision, ruggedness and robustness. The developed method can be a valuable alternative to the current ion-exchange chromatographic method mentioned in the literature. To the best of our knowledge, a rapid Liquid Chromatography (LC) method, which separates inorganic Nitrite and Nitrate impurities of Nitroglycerin, disclosed in this investigation was not published elsewhere.
引用
收藏
页码:22 / 30
页数:9
相关论文
共 50 条
  • [21] An isocratic high performance liquid chromatographic method for quantification of mycophenolic acid and its glucuronide metabolite in human serum using liquid-liquid extraction: Application to human pharmacokinetic studies
    Bahrami, Gholamreza
    Mohammadi, Bahareh
    CLINICA CHIMICA ACTA, 2006, 370 (1-2) : 185 - 190
  • [22] Chemical speciation and recovery of gold(I, III) from wastewater and silver by liquid-liquid extraction with the ion-pair reagent amiloride mono hydrochloride and AAS determination
    El-Shahawi, M. S.
    Bashammakh, A. S.
    Bahaffi, S. O.
    TALANTA, 2007, 72 (04) : 1494 - 1499
  • [23] Fast and simple procedure for liquid–liquid extraction of 136 analytes from different drug classes for development of a liquid chromatographic-tandem mass spectrometric quantification method in human blood plasma
    Daniela Remane
    Markus R. Meyer
    Frank T. Peters
    Dirk K. Wissenbach
    Hans H. Maurer
    Analytical and Bioanalytical Chemistry, 2010, 397 : 2303 - 2314
  • [24] Development of an Ion-Pair Dispersive Liquid-Liquid Microextraction Method Based on a Ternary Deep Eutectic Solvent for Determination of Some Herbicide Residues in Edible Oil Samples
    Torbati, Mohammadali
    Milani, Payam Gonbari
    Farajzadeh, Mir Ali
    Mogaddam, Mohammad Reza Afshar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (01) : 88 - 95
  • [25] RAPID AND SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR METFORMIN IN PLASMA AND URINE USING ION-PAIR EXTRACTION TECHNIQUES
    KEAL, J
    SOMOGYI, A
    JOURNAL OF CHROMATOGRAPHY, 1986, 378 (02): : 503 - 508
  • [26] Development and validation of a reversed-phase ion-pair high-performance liquid chromatographic method for the determination of risedronate in pharmaceutical preparations
    Kyriakides, Dernetra
    Panderi, Irene
    ANALYTICA CHIMICA ACTA, 2007, 584 (01) : 153 - 159
  • [27] An improved high-throughput liquid chromatographic/tandem mass spectrometric method for terbinafine quantification in human plasma, using automated liquid-liquid extraction based on 96-well format plates
    Dotsikas, Yannis
    Apostolou, Constantinos
    Kousoulos, Constantinos
    Tsatsou, Georgia
    Loukas, Yannis L.
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (02) : 201 - 208
  • [28] Development, validation and application of an ion-pair reversed-phase liquid chromatography-tandem mass spectrometry method for the quantification of nusinersen
    Zhang, Xiao
    Sha, Chunjie
    Zhang, Wei
    Zhao, Fengjuan
    Zhu, Mingli
    Leng, Guangyi
    Liu, Wanhui
    BIOANALYSIS, 2024, 16 (05) : 305 - 317
  • [29] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF AMOXICILLIN IN URINE USING SOLID-PHASE, ION-PAIR EXTRACTION AND ULTRAVIOLET DETECTION
    CHULAVATNATOL, S
    CHARLES, BG
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 615 (01): : 91 - 96
  • [30] IMPROVED ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE QUANTIFICATION OF A WIDE VARIETY OF NUCLEOTIDES AND SUGAR NUCLEOTIDES IN ANIMAL-CELLS
    RYLL, T
    WAGNER, R
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (01): : 77 - 88