Experiment and analysis of active vibration isolation system based on rigid pedestal using SDOF actuator

被引:2
|
作者
Xiong, Feng [1 ,2 ]
Li, Yan [1 ,2 ]
Wang, Chunyu [1 ,2 ]
机构
[1] Naval Univ Engn, Inst Noise & Vibrat, Wuhan, Peoples R China
[2] Natl Key Lab Ship Vibrat & Noise, Wuhan, Peoples R China
关键词
active isolation; rigid pedestal; SDOF actuator; global control;
D O I
10.21595/jve.2022.22312
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper is about the active-passive isolation system based on single degree of freedom electromagnetic actuator and focuses on different control effect of different measure points. In view of this problem, the authors analyze the vibration characteristics of the active and passive vibration isolation systems of electromagnetic airbags under single and multi-vibration isolators. Then they decompose the rigid pedestal vibration into two orthogonal components, the vertical translation and the fix axis rotation. After that compare simulation and experiment results in terms of the control effect when the single active-passive isolator location varies. Finally, the authors draw a conclusion about the reason why the rigid pedestal vibration can be globally controlled by arranging more than 3 active-passive isolations and design a multiple isolator system experiment to verify.
引用
收藏
页码:1072 / 1081
页数:10
相关论文
共 50 条
  • [21] Precise positioning and active vibration isolation using piezoelectric actuator with hysteresis compensation
    Badel, Adrien
    Le Breton, Ronan
    Formosa, Fabien
    Hanene, Snoussi
    Lottin, Jacques
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2014, 25 (02) : 155 - 163
  • [22] Active vibration isolation of machine tools using an electro-hydraulic actuator
    Law, M.
    Wabner, M.
    Colditz, A.
    Kolouch, M.
    Noack, S.
    Ihlenfeldt, S.
    CIRP JOURNAL OF MANUFACTURING SCIENCE AND TECHNOLOGY, 2015, 10 : 36 - 48
  • [23] Active vibration isolation using an inertial actuator with local displacement feedback control
    Benassi, L
    Elliott, SJ
    JOURNAL OF SOUND AND VIBRATION, 2004, 278 (4-5) : 705 - 724
  • [24] Active vibration isolation using an inertial actuator with local force feedback control
    Benassi, L
    Elliott, SJ
    Gardonio, P
    JOURNAL OF SOUND AND VIBRATION, 2004, 276 (1-2) : 157 - 179
  • [25] Analysis and design of a linear, permanent magnet, reciprocating actuator for active vibration isolation
    Rens, J
    Clark, RE
    Howe, D
    RARE EARTH MAGNETS AND THEIR APPLICATIONS, 2002, : 299 - 306
  • [26] Active vibration isolation with a dielectric elastomer stack actuator
    Kaal, William
    Bartel, Torsten
    Herold, Sven
    SMART MATERIALS AND STRUCTURES, 2017, 26 (05)
  • [27] Vibration control of serially connected isolation System using piezoelectric actuator
    Liu, Yanhui
    Tan, Ping
    Zhou, Fulin
    Du, Yongfeng
    Yan, Weiming
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 2112 - +
  • [28] Active Vibration Isolation System (AVIS) using a Voice Coil Actuator to improve Free Space Optics Communication
    Ab Rahim, Syazwani
    Muthalif, Asan G. A.
    Tunthim, Khairiah K.
    Nordin, N. H. Divana
    2019 IEEE 10TH CONTROL AND SYSTEM GRADUATE RESEARCH COLLOQUIUM (ICSGRC), 2019, : 189 - 194
  • [29] An inerter-based active vibration isolation system
    Alujevic, Neven
    Cakmak, Damjan
    Wolf, Hinko
    Jokic, Marko
    INTERNATIONAL CONFERENCE ON ENGINEERING VIBRATION (ICOEV 2017), 2018, 148
  • [30] Two-axis Lorentz actuator for active vibration isolation system in optical payloads
    Yuan, Zhongxiang
    Zhang, Zhengguang
    Zeng, Lizhan
    Huang, Zhiwei
    Wu, Jiulin
    Li, Xiaoqing
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2024, 219