Accuracy evaluation of two-dimensional straightness measurement method based on optical meter

被引:9
|
作者
Jurevicius, Mindaugas [1 ]
Skeivalas, Jonas [2 ]
Urbanavicius, Robertas [1 ]
机构
[1] Vilnius Gediminas Tech Univ, Dept Machine Engn, Vilnius, Lithuania
[2] Vilnius Gediminas Tech Univ, Dept Geodesy & Cadastre, Vilnius, Lithuania
关键词
Accuracy evaluation; Straightness measurement; Optical meter; Deviations;
D O I
10.1016/j.measurement.2012.10.012
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The article analyses the accuracy evaluation of non-contact optical mechatronic two dimensional devices for straightness measuring. Measurement principles of the device are based on the evaluation of the position from the phase difference of two signals where one of them is generated by a non-movable photodiode, acting as a reference source, and the other one is attached to the moveable part of the technological machine. The device can be used for measurement, diagnosis and accuracy testing of mechatronic devices, robotics and technological machines. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:960 / 963
页数:4
相关论文
共 50 条
  • [31] Resolution of two-dimensional currents in superconductors from a two-dimensional magnetic field measurement by the method of regularization
    Feldmann, DM
    PHYSICAL REVIEW B, 2004, 69 (14): : 144515 - 1
  • [32] Approximation Accuracy of Gaussian-Optical Approach Applied to Two-Dimensional Optical Microcavities
    Fukushima, Takehiro
    2017 19TH INTERNATIONAL CONFERENCE ON TRANSPARENT OPTICAL NETWORKS (ICTON), 2017,
  • [33] Spatial straightness error evaluation based on three-dimensional least squares method
    Wang, Bingjie
    Zhao, Junpeng
    Wang, Chunjie
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2014, 40 (10): : 1477 - 1480
  • [34] The accuracy of a three-dimensional face model reconstructing method based on conventional clinical two-dimensional photos
    Bochun Mao
    Jing Li
    Yajing Tian
    Yanheng Zhou
    BMC Oral Health, 22
  • [35] The accuracy of a three-dimensional face model reconstructing method based on conventional clinical two-dimensional photos
    Mao, Bochun
    Li, Jing
    Tian, Yajing
    Zhou, Yanheng
    BMC ORAL HEALTH, 2022, 22 (01)
  • [36] A Study on Evaluation Method for Beam Profile of Phased Array by Using Two-Dimensional Measurement Equipment
    Yukawa, Kazuki
    Matsumuro, Takayuki
    Ishizaki, Toshio
    Ishikawa, Yohei
    IEICE TRANSACTIONS ON ELECTRONICS, 2023, E106C (11) : 643 - 650
  • [37] Shape measurement and reconstruction of solar concentrator based on two-dimensional phase shift method
    Zhu, Huibin
    Wang, Zhifeng
    Wang, Huarong
    Yu, Qiang
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, SOLARPACES 2014, 2015, 69 : 1921 - 1927
  • [38] Two-dimensional stitching interferometry based on tilt measurement
    Huang, Lei
    Idir, Mourad
    Zuo, Chao
    Wang, Tianyi
    Tayabaly, Kashmira
    Lippmann, Erich
    OPTICS EXPRESS, 2018, 26 (18): : 23278 - 23286
  • [39] Measurement and comparison of one- and two-dimensional modulation transfer function of optical imaging systems based on the random target method
    Kang, Jiqiang
    Hao, Qun
    Cheng, Xuemin
    OPTICAL ENGINEERING, 2014, 53 (10)
  • [40] TWO-DIMENSIONAL WIND TUNNEL MEASUREMENT CORRECTIONS BY THE SINGULARITY METHOD
    Abdullah, Taha Ahmed
    Petrovic, Zlatko
    Stefanovic, Zoran
    Kostic, Ivan
    Isakovic, Jovan
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2015, 22 (03): : 557 - 565