Combining low tube voltage and iterative reconstruction for contrast-enhanced CT imaging of the chest-Initial clinical experience

被引:26
|
作者
Li, Q. [1 ]
Yu, H. [1 ]
Zhang, L. [2 ]
Fan, L. [1 ]
Liu, S. -y. [1 ]
机构
[1] Second Mil Med Univ, Changzheng Hosp, Dept Radiol, Shanghai 200003, Peoples R China
[2] Lin Yi Peoples Hosp, Dept Radiol, Linyi, Shandong, Peoples R China
基金
中国国家自然科学基金; 上海市自然科学基金;
关键词
DOSE REDUCTION; COMPUTED-TOMOGRAPHY; QUALITY; ANGIOGRAPHY; ALGORITHM;
D O I
10.1016/j.crad.2012.12.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the image quality of contrast-enhanced chest computed tomography (CT) with low tube voltage settings using an iterative reconstruction algorithm (iDose4) and standard dose filtered back projection (FBP) CT in patients with normal body mass index (BMI). MATERIALS AND METHODS: Eighty patients with normal BMI were referred for a contrast-enhanced chest CT. Patients were randomly assigned into two groups: 120 kVp and 80 kVp. Standard convolution FBP was used to reconstruct the 120 kVp group (A) and 80 kVp group (C) image sets and iterative reconstruction (iDose4) was used to reconstruct the 80 kVp group (B) image sets. The mean image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and effective dose (ED) were calculated for each protocol. Image quality was graded (scale: 1-3) and compared among the three groups. RESULTS: The radiation dose was 71.35% less for the low-voltage protocol. Noise was significantly lower in the low-voltage images reconstructed with iDose4 (group B) compared with images reconstructed with FBP (group C). Group B had the highest SNR and CNR. There was no difference in subjective image quality scores between groups B and A (p > 0.05). CONCLUSIONS: Compared with standard FBP reconstruction, the iDose4 iterative reconstruction yields higher SNR, CNR, and better image quality in contrast-enhanced chest CT with low tube voltage settings. (C) 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E249 / E253
页数:5
相关论文
共 50 条
  • [31] Peripheral contrast-enhanced MR angiography at 3.0T, improved spatial resolution and low dose contrast: initial clinical experience
    Nael, Kambiz
    Krishnam, Mayil
    Nael, Ali
    Ton, Anthony
    Ruehm, Stefan G.
    Finn, J. Paul
    EUROPEAN RADIOLOGY, 2008, 18 (12) : 2893 - 2900
  • [32] Can Iterative Reconstruction Improve Imaging Quality for Lower Radiation CT Perfusion? Initial Experience
    Lin, C. J.
    Wu, T. H.
    Lin, C. H.
    Hung, S. C.
    Chiu, C. F.
    Liu, M. -J.
    Teng, M. M. H.
    Chang, F. C.
    Guo, W. Y.
    Chang, C. Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (08) : 1516 - 1521
  • [33] Contrast-enhanced MR imaging of the breast at 3.0 and 1.5 T in the same patients: Initial experience
    Kuhl, CK
    Jost, P
    Morakkabati, N
    Zivanovic, O
    Schild, HH
    Gieseke, J
    RADIOLOGY, 2006, 239 (03) : 666 - 676
  • [34] Exploring the variability of radiomic features of lung cancer lesions on unenhanced and contrast-enhanced chest CT imaging
    Tamponi, Matteo
    Crivelli, Paola
    Montella, Rino
    Sanna, Fabrizio
    Gabriele, Domenico
    Poggiu, Angela
    Sanna, Enrico
    Marini, Piergiorgio
    Meloni, Giovanni B.
    Sverzellati, Nicola
    Conti, Maurizio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 321 - 331
  • [35] Feasibility Assessment of Low Iodine Flow Rate Imaging in Abdominal Contrast-enhanced CT
    Li, Ye
    Zhang, Hui-mao
    Li, Hong-yan
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON BIOMEDICAL AND BIOLOGICAL ENGINEERING, 2016, : 478 - 481
  • [36] Dynamic contrast-enhanced MR imaging in osteoid osteoma: relationships with clinical and CT characteristics
    P. Pottecher
    E. Sibileau
    S. Aho
    B. Hamze
    C. Parlier
    J. D. Laredo
    V. Bousson
    Skeletal Radiology, 2017, 46 : 935 - 948
  • [37] Dynamic contrast-enhanced MR imaging in osteoid osteoma: relationships with clinical and CT characteristics
    Pottecher, P.
    Sibileau, E.
    Aho, S.
    Hamze, B.
    Parlier, C.
    Laredo, J. D.
    Bousson, V.
    SKELETAL RADIOLOGY, 2017, 46 (07) : 935 - 948
  • [38] Hepatic epithelioid angiomyolipoma: clinical features and imaging findings of contrast-enhanced ultrasound and CT
    Tan, Y.
    Xie, X.
    Lin, Y.
    Huang, T.
    Huang, G.
    CLINICAL RADIOLOGY, 2017, 72 (04) : 339.e1 - 339.e6
  • [39] DOES INITIAL CONTRAST-ENHANCED CT IMPACT ON CLINICAL OUTCOMES OF PATIENTS WITH COLON DIVERTICULAR BLEEDING?
    Kurosaki, Shigeyuki
    Toda, Nobuo
    Arai, Junya
    Kurokawa, Ken
    Shibata, Chikako
    Funato, Kazuyoshi
    Kondou, Mayuko
    Takagi, Kaoru
    Kojima, Kentaro
    Ooki, Takamasa
    Seki, Michiharu
    Tagawa, Kazumi
    GASTROINTESTINAL ENDOSCOPY, 2018, 87 (06) : AB98 - AB99
  • [40] DOES INITIAL CONTRAST-ENHANCED CT IMPACT ON CLINICAL OUTCOMES OF PATIENTS WITH COLON DIVERTICULAR BLEEDING?
    Takekuma, Yuto
    Kurosaki, Sigeyuki
    Tanno, Erika
    Suzuki, Tasuku
    Nakahara, Takenori
    Abe, Toshiaki
    Kitamura, Yuri
    Sato, Koki
    Kondo, Mayuko
    Kojima, Kentaro
    Seki, Michiharu
    Toda, Nobuo
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (06) : AB479 - AB479