Event reconstruction in NEXT using the ML-EM algorithm

被引:2
|
作者
Simon, A. [1 ]
Ferrario, P. [1 ]
Izmaylov, A. [1 ]
机构
[1] UV, CSIC, Inst Fis Corpuscular, Valencia, Spain
关键词
NEXT; ML-EM; neutrinoless double beta decay;
D O I
10.1016/j.nuclphysbps.2015.10.010
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The NEXT collaboration aims to find the neutrinoless double beta decay in Xe-136. The rareness of this decay demands an exceptional background rejection. This can be obtained with an excellent energy resolution, which has been already demonstrated in the NEXT prototypes. In addition to this, the beta beta 0 nu decay in gas produces a characteristic topological signal which could be an extremely useful extra handle to avoid background events. The need for a satisfactory topology reconstruction has led the NEXT Collaboration to implement the Maximum Likelihood Expectation Maximization method (ML-EM) in the data processing scheme. ML-EM is a generic iterative algorithm for many kinds of inverse problems. Although this method is well known in medical imaging and has been used widely in Positron Emission Tomography, it has never been applied to a time projection chamber. First results and studies of the performance of the method will be presented in this poster.
引用
收藏
页码:2624 / 2626
页数:3
相关论文
共 50 条
  • [31] COMPARISON BETWEEN ML-EM AND WLS-CG ALGORITHMS FOR SPECT IMAGE-RECONSTRUCTION
    TSUI, BMW
    ZHAO, XD
    FREY, EC
    GULLBERG, GT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (06) : 1766 - 1772
  • [32] ON THE USE OF A MULTI-THREADED OPERATING SYSTEM FOR AN EFFICIENT PARALLEL IMPLEMENTATION OF THE ML-EM ALGORITHM FOR PET IMAGE-RECONSTRUCTION
    BASTIAENS, K
    LEMAHIEU, I
    DESMEDT, P
    APPLICATIONS IN PARALLEL AND DISTRIBUTED COMPUTING, 1994, 44 : 31 - 39
  • [33] ML-EM based dual tracer PET image reconstruction with inclusion of prompt gamma attenuation
    Pfaehler, Elisabeth
    Niekaemper, Debora
    Scheins, Juergen
    Shah, N. Jon
    Lerche, Christoph W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (01):
  • [34] Application of the ML-EM algorithm in the suppression of Compton background of gamma-ray spectroscopy system
    Hoang, Sy Minh Tuan
    Sun, Gwang Min
    Baek, Hani
    Kim, Jiseok
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (03) : 2137 - 2146
  • [35] ML-EM Reconstruction Model including Total Variation for Low Dose PET High Resolution Data
    Chavez-Rivera, Lucia B.
    Ortega-Maynez, Leticia
    Mejia, Jose
    Mederos, Boris
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [36] A hybrid ML-EM algorithm for calculation of maximum likelihood estimates in semiparametric shared frailty models
    Vu, HTV
    Knuiman, MW
    COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2002, 40 (01) : 173 - 187
  • [37] A Study on PET Image Quality Using Both Strong Magnetic Fields and a ML-EM Positron Range Correction Algorithm
    Burdette, D.
    Albani, D.
    Chesi, E.
    Clinthorne, N. H.
    Cochran, E.
    Honscheid, K.
    Huh, S. S.
    Kagan, H.
    Knopp, M.
    Lacasta, C.
    Mikuz, M.
    Schmalbrock, P.
    Studen, A.
    Weihammer, P.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3646 - +
  • [38] Application of the ML-EM algorithm in the suppression of Compton background of gamma-ray spectroscopy system
    Sy Minh Tuan Hoang
    Gwang Min Sun
    Hani Baek
    Jiseok Kim
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 2137 - 2146
  • [39] Temperature distribution measurement based on ML-EM method using enclosed acoustic CT system
    1600, International Frequency Sensor Association, 46 Thorny Vineway, Toronto, ON M2J 4J2, Canada (150):
  • [40] The effects of incorrect modeling on noise and resolution properties of ML-EM images
    Wilson, DW
    Barrett, HH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 768 - 773