Using thermostats for indoor climate control in offices: The effect on thermal comfort and heating/cooling energy use

被引:30
|
作者
Wang, Haiying [1 ,2 ]
Olesen, Bjarne W. [2 ]
Kazanci, Ongun B. [2 ]
机构
[1] Qingdao Univ Technol, Dept Environm & Municipal Engn, 11 Fushun Rd, Qingdao, Peoples R China
[2] Tech Univ Denmark, Dept Civil Engn, Int Ctr Indoor Environm & Energy, Nils Koppels Alle,Bldg 402, DK-2800 Lyngby, Denmark
基金
中国国家自然科学基金;
关键词
Room temperature control; Air temperature; Operative temperature; Energy use; Thermal comfort; Heating/cooling system; Convective system; Radiant system;
D O I
10.1016/j.enbuild.2018.12.030
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The most commonly used thermostat control variable in heating, ventilating and air-conditioning systems is air temperature. However, people's thermal comfort responds to operative temperature more directly than air temperature. Will the adoption of operative temperature based control lead to better thermal comfort and how will this affect the energy use? To get a better understanding about these questions, simulations have been performed based on three heating and cooling systems in three different geographical locations (Copenhagen, Denmark, Paris, France and Rome, Italy). The three systems are fan-coil system representing convective system and two radiant systems: floor heating/cooling system and radiant ceiling heating/cooling panel system. The results show that air temperature based thermostat control and operative temperature based thermostat control had different impacts on fan-coil system and radiant systems. For fan-coil system, the use of operative temperature based thermostat control had better thermal comfort conditions and higher energy use than that of air temperature based thermostat control. For the two radiant systems, the results were the opposite. The results were almost the same in different locations. Besides, the thermal comfort difference between the two controls of north office was smaller than that of south office. For fan-coil system, in south office, compared with air temperature based thermostat control, the hours of Cat. I (-0.2 <= PMV <= 0.2) increased 8.3% for building in Copenhagen, 8.8% paris and 14.2% Rome hours of Cat. IV (PMV <-0.7 or PMV > 0.7) decreased 2.5%, 3.9% and 7.1%, respectively, when operative temperature based thermostat control was used. Meanwhile, total energy supply increased 13.7% in Copenhagen, 14.3% in Paris and 12.7% in Rome. For radiant systems, the total energy use reduced 3.3% to 8.3% depending on location and type of system when operative temperature based control was used. With this reduction of energy use, PMV index in south office was still within the range of +/- 0.7 in most cases, which satisfied the thermal comfort requirement of Cat. III (-0.7 <= PMV <= 0.7) of EN 15251. Based on the results, it is suggested that air temperature based thermostat control be used in fan-coil system and operative temperature based thermostat control be used in radiant system in north office. For south office, operative temperature based thermostat control was considered better for fan-coil system and could be more energy efficient when used in radiant heating and cooling systems. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 83
页数:13
相关论文
共 50 条
  • [31] Climate control in broiler houses: A thermal model for the calculation of the energy use and indoor environmental conditions
    Costantino, Andrea
    Fabrizio, Enrico
    Ghiggini, Andrea
    Bariani, Mauro
    ENERGY AND BUILDINGS, 2018, 169 : 110 - 126
  • [32] Optimized Intelligent Control System for Indoor Thermal Comfort and Energy Management of Buildings
    Shaikh, Pervez Hameed
    Nor, Nursyarizal Bin Mohd
    Nallagownden, Perumal
    Elamvazuthi, Irraivan
    2014 5TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS 2014), 2014,
  • [33] The CPS-Based Simulation of Indoor Thermal Comfort Control with Energy Saving
    Wang, Jinlong
    Zhao, Qianchuan
    Zhao, Yin
    INTERNATIONAL JOURNAL OF INTERDISCIPLINARY TELECOMMUNICATIONS AND NETWORKING, 2015, 7 (01) : 27 - 43
  • [34] Study of the thermal comfort, of the energy consumption and of the indoor environment control in surgery rooms
    Melhado, MA
    Beyer, PO
    Hensen, JM
    Siqueira, LFG
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3160 - 3165
  • [35] A Heating Agent using a Personalised Thermal Comfort Model to Save Energy
    Auffenberg, Frederik
    Stein, Sebastian
    Rogers, Alex
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON AUTONOMOUS AGENTS & MULTIAGENT SYSTEMS (AAMAS'15), 2015, : 1799 - 1800
  • [36] Application of Combined Passive Cooling and Passive Heating Techniques to Achieve Thermal Comfort in a Hot Dry Climate
    Garcia Chavez, Jose Roberto
    Melchor, Francisco Fernandez
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 1669 - +
  • [37] Using personal comfort systems during the post-heating season in a cold climate: A field study in offices
    Liu, Bingbing
    Wang, Haiying
    Ji, Ke
    Ge, Baowei
    Zhang, Xiaoxia
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 45
  • [38] Thermal comfort performance and energy-efficiency evaluation of six personal heating/cooling devices
    Tang, Yin
    Yu, Hang
    Zhang, Kege
    Niu, Kexin
    Mao, Huice
    Luo, Maohui
    BUILDING AND ENVIRONMENT, 2022, 217
  • [39] Flipped townhouses: the impact of layout changes on heating and cooling energy load and occupants' thermal comfort
    Kroll, David
    Sharifi, Ehsan
    Arakawa Martins, Larissa
    Croffi Calixto, Juliana
    Soebarto, Veronica
    ARCHITECTURAL SCIENCE REVIEW, 2025,
  • [40] ENHANCING THERMAL COMFORT IN BUILDINGS Innovations in Sustainable Cooling and Heating Systems Utilizing Geothermal Energy
    Kaid, Noureddine
    Bayram, Mustafa
    Osra, Oumr Adnan
    Almutery, Sultan Bader
    Hassan, Ahmed R.
    Menni, Younes
    THERMAL SCIENCE, 2023, 27 (4B): : 3477 - 3486