Evaluation of stability and capsular bag opacification of a new foldable adjustable intraocular lens

被引:18
|
作者
MacLean, Kyle D. [1 ]
Werner, Liliana [1 ]
Kramer, Gregory D. [1 ]
Farukhi, M. Aabid [1 ]
Gardiner, Gareth L. [1 ]
Kahook, Malik Y. [2 ]
Mamalis, Nick [1 ]
机构
[1] Univ Utah, John A Moran Eye Ctr, Dept Ophthalmol & Visual Sci, Salt Lake City, UT 84132 USA
[2] Univ Colorado, Sch Med, Dept Ophthalmol, Aurora, CO USA
来源
关键词
cataract surgery; intraocular lens; posterior capsule opacification; ZEALAND ALBINO RABBITS; CATARACT-SURGERY; FOLLOW-UP; REGENERATION; IMPLANTATION; PREVENTION; EXTRACTION; OUTCOMES;
D O I
10.1111/ceo.12526
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundIncorrect lens power remains one of the most common reasons for intraocular lens explantation/exchange. We evaluated stability and effect on capsular bag opacification of a new foldable modular lens system, with a base component and an optic component in rabbit eyes. MethodsBilateral phacoemulsification was performed on six rabbits; one eye received the test lens (Harmoni Modular Lens, ClarVista Medical), whereas the other received a single-piece hydrophobic acrylic control lens (SA60AT, Alcon). Slit-lamp examinations were performed at postoperative weeks 1, 2, 3, 4 and 6. All rabbits were sacrificed at week 6. After enucleation, the eyes were examined grossly from the Miyake-Apple view. Following, all globes were sectioned and processed for histopathological examination. ResultsThe modular lens was stable in all six rabbits. Uveal biocompatibility was similar to or better in the test eyes when compared with control eyes up to 6 weeks postoperatively. Overall, capsular bag opacification was found to be significantly lower in the test eyes when compared with control eyes. At the 6-week gross examination, central posterior capsule opacification was scored as 0.580.73 in the test group, and as 3.00 +/- 1.26 in the control group (paired two samples for means t-test; two-tail P=0.005). ConclusionsThe Harmoni Modular system remains stable within the capsular bag after implantation. Due to the design of the base component featuring long loops, along with peripheral anterior and posterior square edges, the lens appeared to prevent overall capsular bag opacification in the rabbit model.
引用
收藏
页码:648 / 654
页数:7
相关论文
共 50 条
  • [41] Capsulorhexis ovaling and capsular bag stretch after rigid and foldable intraocular lens implantation - Experimental study in pediatric human eyes
    Pandey, SK
    Werner, L
    Wilson, ME
    Izak, AM
    Apple, DJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (10): : 2183 - 2191
  • [42] Additional multifocal sulcus-based intraocular lens: Alternative to multifocal intraocular lens in the capsular bag
    Schrecker, Jens
    Kroeber, Sandra
    Eppig, Timo
    Langenbucher, Achim
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (04): : 548 - 555
  • [43] Evaluation of a human capsular bag model for secondary cataract determination after intraocular lens implantation
    A. Liekfeld
    N. Pahms
    N. Torun
    A. U. Porstmann
    J. Jaroszewski
    C. Hartmann
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 43 - 48
  • [44] Foldable posterior chamber intraocular lens implantation in the absence of capsular and zonular support
    Ramocki, JM
    Shin, DH
    Glover, BK
    Morris, DA
    Kim, YY
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (02) : 213 - 216
  • [45] Evaluation of a human capsular bag model for secondary cataract determination after intraocular lens implantation
    Liekfeld, A
    Pahms, N
    Torun, N
    Porstmann, AU
    Jaroszewski, J
    Hartmann, C
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (01) : 43 - 48
  • [46] Intraoperative miotics and posterior capsular opacification following phacoemulsification with intraocular lens insertion
    Phillips, B
    Crandall, AS
    Mamalis, N
    Olson, RJ
    OPHTHALMIC SURGERY AND LASERS, 1997, 28 (11): : 911 - 914
  • [47] The intraocular lens: challenges in the prevention and therapy of infectious endophthalmitis and posterior capsular opacification
    Parsons, C
    Jones, DS
    Gorman, SP
    EXPERT REVIEW OF MEDICAL DEVICES, 2005, 2 (02) : 161 - 173
  • [48] Unintended Placement of Intraocular Lens Haptics in the Sulcus and Association with Posterior Capsular Opacification
    Denis, Raphaelle
    Nassrallah, Georges
    Dias, Ana Beatriz
    Ito, Hiroaki
    Mastromonaco, Christina
    Saheb, Nabil
    Burnier, Miguel N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [49] Research Progress Concerning a Novel Intraocular Lens for the Prevention of Posterior Capsular Opacification
    Zhang, Yidong
    Zhang, Chengshou
    Chen, Silong
    Hu, Jianghua
    Shen, Lifang
    Yu, Yibo
    PHARMACEUTICS, 2022, 14 (07)
  • [50] The effect of the haptic portion of intraocular lens on the development of posterior capsular opacification in rabbit
    Yoon, YD
    Lim, SJ
    Kim, HB
    YONSEI MEDICAL JOURNAL, 1999, 40 (03) : 232 - 237