Distribution and Anisotropy of Dislocations in Cold-drawn Pearlitic Steel Wires Analyzed Using Micro-beam X-ray Diffraction

被引:16
|
作者
Sato, Shigeo [1 ]
Shobu, Takahisa [2 ,3 ]
Satoh, Kozue
Ogawa, Hiromi
Wagatsuma, Kazuaki
Kumagai, Masayoshi [4 ]
Imafuku, Muneyuki [4 ]
Tashiro, Hitoshi
Suzuki, Shigeru [5 ]
机构
[1] Ibaraki Univ, Grad Sch Sci & Engn, Hitachi, Ibaraki 3168511, Japan
[2] Japan Atom Energy Agcy, Mikazuki, Hyogo 6795148, Japan
[3] Tohoku Univ, Inst Mat Res, Aoba Ku, Sendai, Miyagi 9808577, Japan
[4] Tokyo City Univ, Fac Engn, Tokyo 1588557, Japan
[5] Tohoku Univ, Inst Multidisciplinary Res Adv Mat, Aoba Ku, Sendai, Miyagi 9808577, Japan
基金
日本学术振兴会;
关键词
pearlitic steel; dislocation density; dislocation arrangement; X-ray diffraction; line profile analysis; HYDROGEN EMBRITTLEMENT SUSCEPTIBILITY; INDUCED RESIDUAL-STRESSES; HYPEREUTECTOID STEEL; STRENGTH; MICROSTRUCTURE; CEMENTITE; FERRITE; STRAINS; CRYSTALS;
D O I
10.2355/isijinternational.55.1432
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
To characterize the distribution and anisotropy of dislocations in cold-drawn pearlitic steel wires, X-ray diffraction line-profile analysis was performed using synchrotron radiation micro-beams. An analytical procedure for correcting the instrumental line broadening for highly directional micro-beams was developed using diffraction profiles of standard CeO2 powder. Although the CeO2 powder line profile includes line broadening due to its microstructural imperfections, the instrumental broadening can be obtained by estimating the effect of the microstructural imperfections on the line broadening. The plastic shear strain was generally more severe near the surface than the center of the wire, whereas the dislocation density distribution was almost constant from the center to the surface. On the other hand, the dislocation rearrangement, which evolves the dislocation cell structure, progressed closer to the surface. It was also revealed that a difference between the hardness in axial and transverse wire directions could be explained by anisotropic dislocation density. Line-profile analysis based on diffraction data at elevated temperatures was performed. Whereas the cementite recovery progressed at a constant rate, the ferrite phase recovery rate was temperature-dependent, suggesting that the ferrite phase recovery was less related to that of the cementite phase.
引用
收藏
页码:1432 / 1438
页数:7
相关论文
共 50 条
  • [32] Measurement of hydrogen trapping in cold-work dislocations using synchrotron X-ray diffraction
    Swan, Helen
    Styman, Paul
    Wilcox, Hannah
    Bowden, Natasha
    Ungar, Tamas
    Connor, Leigh
    Garner, Alistair
    Cole-Baker, Aidan
    Binks, Paul
    Smith, Charlotte
    Sikotra, Shyam
    Hawes, Jonathan
    Ortner, Susan
    JOURNAL OF NUCLEAR MATERIALS, 2022, 571
  • [33] Irradiation effects and micro-structural changes in large grain uranium dioxide fuel investigated by micro-beam X-ray diffraction
    Mieszczynski, C.
    Kuri, G.
    Degueldre, C.
    Martin, M.
    Bertsch, J.
    Borca, C. N.
    Grolimund, D.
    Delafoy, Ch
    Simoni, E.
    JOURNAL OF NUCLEAR MATERIALS, 2014, 444 (1-3) : 274 - 282
  • [34] A STUDY OF COLD-WORKED ALUMINIUM BY AN X-RAY MICRO-BEAM TECHNIQUE .3. THE STRUCTURE OF COLD-WORKED ALUMINIUM
    HIRSCH, PB
    ACTA CRYSTALLOGRAPHICA, 1952, 5 (02): : 172 - 175
  • [35] Application of Confocal Micro-Beam X-Ray Fluorescence in Nondestructive Scanning Analysis of the Distribution of Elements in a Single Hair
    Liu He-he
    Liu Zhi-guo
    Sun Tian-xi
    Peng Song
    Zhao Wei-gang
    Sun Wei-yuan
    Li Yu-de
    Lin Xiao-yan
    Zhao Guang-cui
    Luo Ping
    Ding Xun-liang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (11) : 3153 - 3156
  • [36] A STUDY OF COLD-WORKED ALUMINIUM BY AN X-RAY MICRO-BEAM TECHNIQUE .2. MEASUREMENT OF SHAPES OF SPOTS
    HIRSCH, PB
    ACTA CRYSTALLOGRAPHICA, 1952, 5 (02): : 168 - 172
  • [37] Investigation of the distribution of elements in snail shell with the use of synchrotron-based, micro-beam X-ray fluorescence spectrometry
    Rao, D. V.
    Swapna, M.
    Cesareo, R.
    Brunetti, A.
    Akatsuka, T.
    Yuasa, T.
    Takeda, T.
    Tromba, G.
    Gigante, G. E.
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2009, 23 (04) : 251 - 257
  • [38] Analysis of hydroxyapatite (HAp) texture in regenerated hard tissues using micro-beam X-ray diffractometer technique
    Nakano, T
    Kaibara, K
    Tabata, Y
    Nagata, N
    Enomoto, S
    Marukawa, E
    Umakoshi, Y
    TISSUE ENGINEERING FOR THERAPEUTIC USE 6, 2002, 1243 : 95 - 104
  • [39] A STUDY OF COLD-WORKED ALUMINIUM BY AN X-RAY MICRO-BEAM TECHNIQUE .1. MEASUREMENT OF PARTICLE VOLUME AND MISORIENTATIONS
    HIRSCH, PB
    KELLAR, JN
    ACTA CRYSTALLOGRAPHICA, 1952, 5 (02): : 162 - &
  • [40] A compact micro-beam system using a tapered glass capillary for proton-induced X-ray radiography
    Hasegawa, Jun
    Shiba, Shigeki
    Fukuda, Hitoshi
    Oguri, Yoshiyuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (10): : 2125 - 2129