Distribution and Anisotropy of Dislocations in Cold-drawn Pearlitic Steel Wires Analyzed Using Micro-beam X-ray Diffraction

被引:16
|
作者
Sato, Shigeo [1 ]
Shobu, Takahisa [2 ,3 ]
Satoh, Kozue
Ogawa, Hiromi
Wagatsuma, Kazuaki
Kumagai, Masayoshi [4 ]
Imafuku, Muneyuki [4 ]
Tashiro, Hitoshi
Suzuki, Shigeru [5 ]
机构
[1] Ibaraki Univ, Grad Sch Sci & Engn, Hitachi, Ibaraki 3168511, Japan
[2] Japan Atom Energy Agcy, Mikazuki, Hyogo 6795148, Japan
[3] Tohoku Univ, Inst Mat Res, Aoba Ku, Sendai, Miyagi 9808577, Japan
[4] Tokyo City Univ, Fac Engn, Tokyo 1588557, Japan
[5] Tohoku Univ, Inst Multidisciplinary Res Adv Mat, Aoba Ku, Sendai, Miyagi 9808577, Japan
基金
日本学术振兴会;
关键词
pearlitic steel; dislocation density; dislocation arrangement; X-ray diffraction; line profile analysis; HYDROGEN EMBRITTLEMENT SUSCEPTIBILITY; INDUCED RESIDUAL-STRESSES; HYPEREUTECTOID STEEL; STRENGTH; MICROSTRUCTURE; CEMENTITE; FERRITE; STRAINS; CRYSTALS;
D O I
10.2355/isijinternational.55.1432
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
To characterize the distribution and anisotropy of dislocations in cold-drawn pearlitic steel wires, X-ray diffraction line-profile analysis was performed using synchrotron radiation micro-beams. An analytical procedure for correcting the instrumental line broadening for highly directional micro-beams was developed using diffraction profiles of standard CeO2 powder. Although the CeO2 powder line profile includes line broadening due to its microstructural imperfections, the instrumental broadening can be obtained by estimating the effect of the microstructural imperfections on the line broadening. The plastic shear strain was generally more severe near the surface than the center of the wire, whereas the dislocation density distribution was almost constant from the center to the surface. On the other hand, the dislocation rearrangement, which evolves the dislocation cell structure, progressed closer to the surface. It was also revealed that a difference between the hardness in axial and transverse wire directions could be explained by anisotropic dislocation density. Line-profile analysis based on diffraction data at elevated temperatures was performed. Whereas the cementite recovery progressed at a constant rate, the ferrite phase recovery rate was temperature-dependent, suggesting that the ferrite phase recovery was less related to that of the cementite phase.
引用
收藏
页码:1432 / 1438
页数:7
相关论文
共 50 条
  • [1] Relationship between dislocations and residual stresses in cold-drawn pearlitic steel analyzed by energy-dispersive X-ray diffraction
    Sato, Shigeo
    Wagatsuma, Kazuaki
    Suzuki, Shigeru
    Kumagai, Masayoshi
    Imafuku, Muneyuki
    Tashiro, Hitoshi
    Kajiwara, Kentaro
    Shobu, Takahiasa
    MATERIALS CHARACTERIZATION, 2013, 83 : 152 - 160
  • [2] X-ray diffraction and Mossbauer spectroscopy studies of cementite dissolution in cold-drawn pearlitic steel
    Chakraborty, J.
    Ghosh, M.
    Ranjan, Rajeev
    Das, G.
    Das, D.
    Chandra, S.
    PHILOSOPHICAL MAGAZINE, 2013, 93 (36) : 4598 - 4616
  • [3] Hydrogen embrittlement and micro-damage in notched specimens of progressively cold-drawn pearlitic steel wires
    Toribio, J.
    Vergara, D.
    Lorenzo, M.
    THEORETICAL AND APPLIED FRACTURE MECHANICS, 2017, 90 : 276 - 286
  • [4] Interactions of stress corrosion cracks in cold drawn pearlitic steel wires: An X-ray micro-computed tomography study
    Ramandi, Hamed Lamei
    Chen, Honghao
    Crosky, Alan
    Saydam, Serkan
    CORROSION SCIENCE, 2018, 145 : 170 - 179
  • [5] Pearlite Interlamellar Spacing and Vickers Micro-Hardness in the Necking Region of Cold-Drawn Pearlitic Steel Wires
    Toribio, Jesus
    Ayaso, Francisco-Javier
    Rodriguez, Rocio
    METALS, 2023, 13 (08)
  • [6] Measurement of dislocation density in cold-drawn steel wires by means of X-Ray Bragg profiles analysis
    Yang Fan
    Fan Yingying
    Jin Yiming
    FRONTIERS OF MECHANICAL ENGINEERING AND MATERIALS ENGINEERING, PTS 1 AND 2, 2012, 184-185 : 1054 - +
  • [7] Measurement of coating thickness on wires by micro-beam X-ray fluorescence
    Rößiger, V.
    Galvanotechnik, 2002, 93 (09): : 2262 - 2265
  • [8] X-RAY RESIDUAL-STRESS MEASUREMENTS ON COLD-DRAWN STEEL WIRE
    WILLEMSE, PF
    NAUGHTON, BP
    VERBRAAK, CA
    MATERIALS SCIENCE AND ENGINEERING, 1982, 56 (01): : 25 - 37
  • [9] Direct microfabrication using an X-ray micro-beam
    Katoh, T
    Zhang, YP
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 1578 - 1581
  • [10] Direct microfabrication using an X-ray micro-beam
    Katoh, T
    Zhang, YP
    Kagoshima, Y
    Tsusaka, Y
    Matsui, J
    SENSORS AND ACTUATORS A-PHYSICAL, 2002, 97-8 : 725 - 728