Planar Hall Effect in Spin Valve Structure for DNA Detection Immobilized with Single Magnetic Bead

被引:0
|
作者
Bajaj, Bharat [1 ]
Thanh, N. T. [1 ]
Kim, C. G. [1 ]
机构
[1] Chungnam Natl Univ, Dept Mat Sci & Engn, Taejon 305764, South Korea
关键词
Bio sensor; magnetic bead detection; Dynabead; MICROBEAD; SENSOR;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There is a considerable effort directed towards understanding and negating the proliferation of infectious diseases by improving the sensitivity of biosensors. We describe the investigation of nucleic acid interactions based on immobilization of thiolated probe DNA followed by the coupling of biotinylated DNA and streptavidin coated Dyna beads on the gold film deposited on the substrate for the further application with the Planar Hall effect in spin valve structure of Ta/NiFe/Cu/NiFe/IrMn/Ta which has been applied to single magnetic bead detection sensor with the size of 3x3 mu m(2). The spin valve structure which incorporates free and pinned layers was used as magnetic field sensor based on the resistance changes when the magnetization orientation in free magnetic layer rotates to the change of external applied magnetic field. It is demonstrated to induce a high sensitivity due to small interlayer coupling between free and pinned layers, and improved signal-to-noise due to very thin active sensing layer; compared to the other structures.. In the results, the sensor performance with single Dynabeads (R) M-280 Streptavidin conjugated with target DNA and probe DNA was reported as a significantly sensitive system with high signals of around 1.4 mu V. These, therefore, can be used well for biomolecule recognition, biotechnology and biosensor application.
引用
收藏
页码:1037 / 1040
页数:4
相关论文
共 50 条
  • [41] Planar Hall effect bridge magnetic field sensors
    Henriksen, A. D.
    Dalslet, B. T.
    Skieller, D. H.
    Lee, K. H.
    Okkels, F.
    Hansen, M. F.
    APPLIED PHYSICS LETTERS, 2010, 97 (01)
  • [42] Magnetic hysteresis and planar Hall effect of Co films
    Lo, C.K.
    Klik, I.
    Liou, Y.
    Chang, C.P.
    Yang, C.S.
    Yao, Y.D.
    Journal of Magnetism and Magnetic Materials, 1998, 177-181 (Pt 2): : 1257 - 1258
  • [43] Magnetic hysteresis and planar Hall effect of Co films
    Lo, CK
    Klik, I
    Liou, Y
    Chang, CP
    Yang, CS
    Yao, YD
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1998, 177 : 1257 - 1258
  • [44] Micromagnetic simulation for detection of a single magnetic microbead or nanobead by spin-valve sensors
    Liu, Yaowen
    Jin, Wei
    Yang, Yaping
    Wang, Zhiguo
    Journal of Applied Physics, 2006, 99 (08):
  • [45] Micromagnetic simulation for detection of a single magnetic microbead or nanobead by spin-valve sensors
    Liu, Yaowen
    Jin, Wei
    Yang, Yaping
    Wang, Zhiguo
    JOURNAL OF APPLIED PHYSICS, 2006, 99 (08)
  • [46] Analytical and micromagnetic modeling for detection of a single magnetic microbead or nanobead by spin valve sensors
    Li, GX
    Wang, SX
    IEEE TRANSACTIONS ON MAGNETICS, 2003, 39 (05) : 3313 - 3315
  • [47] Optical detection of spin Hall effect in metals
    van't Erve, O. M. J.
    Hanbicki, A. T.
    McCreary, K. M.
    Li, C. H.
    Jonker, B. T.
    APPLIED PHYSICS LETTERS, 2014, 104 (17)
  • [48] ANISOTROPY OF PLANAR HALL EFFECT IN A SINGLE CRYSTAL OF NICKEL
    HIRSCH, AA
    KLEEFELD, J
    FRIEDLANDER, G
    PHYSICS LETTERS A, 1971, A 34 (05) : 253 - +
  • [49] Spin valve effect and Hall resistance in a wide parabolic well
    Duarte, CA
    Gusev, GM
    Quivy, AA
    Lamas, TE
    BRAZILIAN JOURNAL OF PHYSICS, 2006, 36 (2A) : 488 - 491
  • [50] Injection and detection of spin current and spin Hall effect in GaAs
    Miah, M. Drish
    MATERIALS LETTERS, 2006, 60 (23) : 2863 - 2866