Impact of cage position on biomechanical performance of stand-alone lateral lumbar interbody fusion: a finite element analysis

被引:9
|
作者
Nan, Chong [1 ]
Ma, Zhanbei [2 ]
Liu, Yuxiu [2 ]
Ma, Liang [2 ]
Li, Jiaqi [1 ]
Zhang, Wei [1 ]
机构
[1] Hebei Med Univ, Dept Spinal Surg, Hosp 3, Shijiazhuang 050000, Hebei, Peoples R China
[2] Cent Hosp, Dept Orthoped, Baoding 1, Baoding 071000, Hebei, Peoples R China
关键词
Stand-alone lateral lumbar interbody fusion; Cage position; Finite element analysis; Adjacent segment degeneration; Cage subsidence; PEDICLE-SCREW FIXATION; ADJACENT; DISEASE; SPINE; DECOMPRESSION; DEGENERATION;
D O I
10.1186/s12891-022-05873-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background This study aimed to compare the biomechanical performance of various cage positions in stand-alone lateral lumbar interbody fusion(SA LLIF). Methods An intact finite element model of the L3-L5 was reconstructed. The model was verified and analyzed. Through changing the position of the cage, SA LLIF was established in four directions: anterior placement(AP), middle placement(MP), posterior placement(PP), oblique placement(OP). A 400 N vertical axial pre-load was imposed on the superior surface of L3 and a 10 N/m moment was applied on the L3 superior surface along the radial direction to simulate movements of flexion, extension, lateral bending, and axial rotation. Various biomechanical parameters were evaluated for intact and implanted models in all loading conditions, including the range of motion (ROM) and maximum stress. Results In the SA LLIF models, the ROM of L4-5 was reduced by 84.21-89.03% in flexion, 72.64-82.26% in extension, 92.5-95.85% in right and left lateral bending, and 87.22-92.77% in right and left axial rotation, respectively. Meanwhile, ROM of L3-4 was mildly increased by an average of 9.6% in all motion directions. Almost all stress peaks were increased after SA LLIF, including adjacent disc, facet joints, and endplates. MP had lower stress peaks of cage and endplates in most motion modes. In terms of the stress on facet joints and disc of the cephalad segment, MP had the smallest increment. Conclusion In our study, SA LLIF risked accelerating the adjacent segment degeneration. The cage position had an influence on the distribution of endplate stress and the magnitude of facet joint stress. Compared with other positions, MP had the slightest effect on the stress in the adjacent facet joints. Meanwhile, MP seems to play an important role in reducing the risk of cage subsidence.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] In Reply to the Letter to the Editor Regarding "Biomechanical Comparison of Stand-Alone and Bilateral Pedicle Screw Fixation for Oblique Lumbar Interbody Fusion Surgery-A Finite Element Analysis"
    Fang, Guofang
    Sang, Hongxun
    WORLD NEUROSURGERY, 2021, 150 : 250 - 250
  • [42] Increased cage angle effects on radiographic outcomes after stand-alone anterior lumbar interbody fusion
    Nguyen, Austin Q.
    Ukogu, Chierika
    Harvey, Jackson P.
    Federico, Vincent P.
    Nolte, Michael T.
    Khanna, Krishn
    Sheha, Evan D.
    Gandhi, Sapan D.
    Phillips, Frank M.
    JOURNAL OF NEUROSURGERY-SPINE, 2023, 39 (02) : 254 - 262
  • [43] FINITE ELEMENT ANALYSIS OF 3D PRINTED STAND-ALONE TRANSFORAMINAL LUMBAR INTERBODY FUSION CAGES UNDER VARIOUS LOADINGS
    Zhang, Yufei
    Kang, Minjae
    Su, Siheng
    PROCEEDINGS OF ASME 2023 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2023, VOL 13, 2023,
  • [44] Comparison of instrumented and stand-alone lateral lumbar interbody fusion for lumbar degenerative disease: a systematic review and meta-analysis
    Jiang, Lianghai
    Liu, Lantao
    Dong, Liang
    Xu, Zhengwei
    Zhang, Xiaobo
    Qian, Lixiong
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [45] A new stand-alone anterior lumbar interbody fusion device: Biomechanical comparison with established fixation techniques
    Cain, CMJ
    Schleicher, P
    Gerlach, R
    Pflugmacher, R
    Scholz, M
    Kandziora, F
    SPINE, 2005, 30 (23) : 2631 - 2636
  • [46] The rate of fusion for stand-alone anterior lumbar interbody fusion: a systematic review
    Manzur, Mustfa
    Virk, Sohrab S.
    Jivanelli, Bridget
    Vaishnav, Avani S.
    McAnany, Steven J.
    Albert, Todd J.
    Iyer, Sravisht
    Gang, Catherine Himo
    Qureshi, Sheeraz
    SPINE JOURNAL, 2019, 19 (07): : 1294 - 1301
  • [47] Comparison of instrumented and stand-alone lateral lumbar interbody fusion for lumbar degenerative disease: a systematic review and meta-analysis
    Lianghai Jiang
    Lantao Liu
    Liang Dong
    Zhengwei Xu
    Xiaobo Zhang
    Lixiong Qian
    BMC Musculoskeletal Disorders, 25
  • [48] Biomechanical comparison of three stand-alone lumbar cages - a three-dimensional finite element analysis
    Chen, Shih-Hao
    Chiang, Ming-Chieh
    Lin, Jin-Fu
    Lin, Shang-Chih
    Hung, Ching-Hua
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [49] Biomechanical comparison of three stand-alone lumbar cages — a three-dimensional finite element analysis
    Shih-Hao Chen
    Ming-Chieh Chiang
    Jin-Fu Lin
    Shang-Chih Lin
    Ching-Hua Hung
    BMC Musculoskeletal Disorders, 14
  • [50] Biomechanical analysis of an interspinous fusion device as a stand-alone and as supplemental fixation to posterior expandable interbody cages in the lumbar spine
    Gonzalez-Blohm, Sabrina A.
    Doulgeris, James J.
    Aghayev, Kamran
    Lee, William E., III
    Volkov, Andrey
    Vrionis, Frank D.
    JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (02) : 209 - 219