Evaluation of biphasic transthoracic defibrillation in an animal model of prolonged ventricular fibrillation

被引:12
|
作者
Scheatzle, MD
Menegazzi, JJ
Allen, TL
Durham, SB
机构
[1] Allegheny Gen Hosp, Med Coll Penn & Hahnemann Univ, Sch Med, MDS,Dept Emergency Med, Pittsburgh, PA 15212 USA
[2] Univ Pittsburgh, Dept Emergency, Pittsburgh, PA USA
关键词
arrhythmia; defibrillation; sudden death; defibrillation waveform; swine;
D O I
10.1111/j.1553-2712.1999.tb01234.x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To determine whether a biphasic defibrillation waveform (BDW) would produce a superior rate of converting prolonged ventricular fibrillation (VF) into a perfusing rhythm and delay the occurrence of asystole and/or pulseless electrical activity (PEA) during the resuscitation attempt, when compared with a monophasic defibrillation waveform (MDW). Methods: The authors performed a prospective, randomized, blinded experiment using an established swine model of prolonged VF. Thirty-four mixed-breed domestic swine (mean mass 22.9 kg) were sedated (ketamine/xylazine), anesthetized (isoflurane), and intubated. Aortic and femoral venous catheters were placed. ECG was monitored continuously. The animals were shocked into VF (3-s, 100-mA, 60-Hz shock), and were untreated for 8 minutes. Advanced Cardiac Life Support (ACLS) began with 1 minute of standardized (Thumper) chest compressions and ventilation. The animals were randomized to treatment with either BDW or MDW. Standard ACLS protocols were followed. The energy sequence was 2.5 J/kg first, 3.5 J/kg second, and 4.5 J/kg for all subsequent shocks. Outcome variables were time to event of asystole/PEA return of spontaneous circulation (ROSC), and one-hour survival. Data were analyzed with two-tailed Fisher's exact test and Kaplan-Meier survival plots (alpha = 0.05). Results: ROSC occurred more frequently in the BDW group (7/17) compared with the MDW group (1/17); p = 0.04. Survival analysis showed that; the BDW significantly delayed the occurrence of asystole/PEA during the resuscitation attempt when compared with the MDW; log-ranked p = 0.02. One-hour survival rates (5/17 BDW and 1/17 MDW, p = 0.17) did not differ. Conclusions: BDW resulted in a superior rate of ROSC and delay in the occurrence of asystole/PEA during the resuscitation attempt when compared with MDW.
引用
收藏
页码:880 / 886
页数:7
相关论文
共 50 条
  • [31] The influence of ventricular fibrillation duration on the defibrillation threshold using biphasic waveforms in humans
    Windecker, S
    Ideker, RE
    Kay, GN
    Plumb, VJ
    Epstein, AE
    CIRCULATION, 1997, 96 (08) : 3241 - 3241
  • [32] Automatic adjustment of biphasic pulse duration in transthoracic defibrillation
    Krasteva, V
    Iliev, I
    Cansell, A
    Daskalov, I
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2000, 24 (05) : 210 - 214
  • [33] Changes in transthoracic impedance during sequential biphasic defibrillation
    Deakin, Charles D.
    Ambler, Jonathan J. S.
    Shaw, Steven
    RESUSCITATION, 2008, 78 (02) : 141 - 145
  • [34] Transthoracic defibrillation of dogs with Edmark, biphasic, and quadriphasic waveforms
    McDaniel, WC
    Magin, T
    Madsen, RW
    Bonagura, JD
    Schuder, JC
    Curtis, JJ
    JOURNAL OF ELECTROCARDIOLOGY, 2002, 35 (01) : 45 - 52
  • [35] Optimal timing for electrical defibrillation after prolonged untreated ventricular fibrillation
    Kolarova, J
    Ayoub, IM
    Yi, Z
    Gazmuri, RJ
    CRITICAL CARE MEDICINE, 2003, 31 (07) : 2022 - 2028
  • [36] Ventricular fibrillation and defibrillation
    Jones, P.
    Lode, N.
    ARCHIVES OF DISEASE IN CHILDHOOD, 2007, 92 (10) : 916 - 921
  • [37] Defibrillation and the upper limit of vulnerability to fibrillation in a transthoracic guinea pig model
    Li, H
    Malkin, RA
    JOURNAL OF ELECTROCARDIOLOGY, 1999, 32 (02) : 159 - 166
  • [38] CPR prior to defibrillation improves outcomes after prolonged ventricular fibrillation
    Tang, WC
    Weil, MH
    Yu, T
    Klouche, K
    Sun, S
    CIRCULATION, 2002, 106 (19) : 664 - 664
  • [39] Low-Tilt Monophasic and Biphasic Waveforms Compared with Standard Biphasic Waveforms in the Transvenous Defibrillation of Ventricular Fibrillation
    Bennett, Johan R.
    Darragh, Karen M.
    Walsh, Simon J.
    Allen, Desmond J.
    Scott, Michael
    Stevenson, Michael
    Adgey, Jennifer A. A.
    Anderson, John M. C. J.
    Manoharan, Ganesh
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (03): : 279 - 289
  • [40] Optimization of transthoracic ventricular defibrillation-biphasic and triphasic shocks, waveform rounding, and synchronized shock delivery
    Kidwai, BJ
    McIntyre, A
    Anderson, J
    Adgey, AAJ
    JOURNAL OF ELECTROCARDIOLOGY, 2002, 35 (03) : 235 - 244