Plaque burden can be assessed using intravascular optical coherence tomography and a dedicated automated processing algorithm: a comparison study with intravascular ultrasound

被引:17
|
作者
Gerbaud, Edouard [1 ,2 ,3 ,4 ,5 ]
Weisz, Giora [6 ,7 ,8 ]
Tanaka, Atsushi [1 ,2 ,9 ]
Luu, Romain [1 ,2 ,10 ]
Osman, Hany Ahmed Salaheldin Hussein [1 ,2 ]
Baldwin, Grace [1 ,2 ]
Coste, Pierre [3 ,4 ,5 ]
Cognet, Laurent [10 ]
Waxman, Sergio [11 ]
Zheng, Hui [12 ,13 ]
Moses, Jeffrey W. [6 ,7 ]
Mintz, Gary S. [6 ,7 ]
Akasaka, Takashi [9 ]
Maehara, Akiko [6 ,7 ]
Tearney, Guillermo J. [1 ,2 ,13 ,14 ,15 ]
机构
[1] Harvard Med Sch, Wellman Ctr Photomed, 40 Blossom St,BHX-604A, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, 40 Blossom St,BHX-604A, Boston, MA 02114 USA
[3] Hop Cardiol Haut Leveque, Cardiol Intens Care Unit, 5 Ave Magellan, F-33600 Pessac, France
[4] Hop Cardiol Haut Leveque, Intervent Cardiol, 5 Ave Magellan, F-33600 Pessac, France
[5] Bordeaux Univ, Bordeaux Cardiothorac Res Ctr, Hop Xavier Arnozan, U1045,Ave Haut Leveque, F-33600 Pessac, France
[6] Columbia Univ, Med Ctr, New York, NY USA
[7] Cardiovasc Res Fdn, 1700 Broadway,9th Floor, New York, NY 10019 USA
[8] Albert Einstein Coll Med, Montefiore Einstein Ctr Heart & Vasc, Univ Hosp, 111 East 210th St, Bronx, NY 10467 USA
[9] Wakayama Med Univ, Dept Cardiovasc Med, 811-1 Kimiidera, Wakayama, Wakayama 6418509, Japan
[10] Bordeaux Univ, Inst Opt, Grad Sch, CNRS,UMR 5298, Rue Francois Miterrand, F-33400 Talence, France
[11] Lahey Clin Med Ctr, Dept Cardiol, 41 Mall Rd, Burlington, MA 01805 USA
[12] Massachusetts Gen Hosp, Biostat Ctr, Boston, MA 02114 USA
[13] Harvard Med Sch, 40 Blossom St, Boston, MA 02114 USA
[14] Massachusetts Gen Hosp, Dept Pathol, 40 Blossom St, Boston, MA 02114 USA
[15] Harvard MIT Hlth Sci & Technol, Boston, MA 02139 USA
基金
美国国家卫生研究院;
关键词
plaque burden; optical coherence tomography; intravascular ultrasound; algorithm; CORONARY-ARTERY-DISEASE; CONSENSUS DOCUMENT; ANGIOGRAPHY; EVENTS; ACQUISITION; PROGRESSION; MORPHOLOGY; STANDARDS; IVUS; OCT;
D O I
10.1093/ehjci/jez185
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Plaque burden (PB) measurement using intravascular optical coherence tomography (IVOCT) is currently thought to be inferior to intravascular ultrasound (IVUS). We developed an automated IVOCT image processing algorithm to enhance the external elastic lamina (EEL) contour. Thus, we investigated the accuracies of standard IVOCT and an IVOCT enhancement algorithm for measuring PB using IVUS as the reference standard. Methods and results The EEL-enhancement algorithm combined adaptive attenuation compensation, exponentiation, angular registration, and image averaging using three sequential frames. In two different laboratories with intravascular imaging expertise, PB was quantified on 200 randomized, matched IVOCT and IVUS images by four independent observers. Fibroatheroma, fibrocalcific plaque, fibrous plaque, pathological intimal thickening (PIT), and mixed plaque were included in each set. Pearson's correlation coefficients between IVUS and standard IVOCT measurements of PB were 0.61, 0.67, 0.76, 0.78, and 0.87 for fibroatheromas, mixed plaques, fibrocalcific plaques, fibrous plaques, and PIT plaques, respectively. Pearson's correlation coefficients increased to 0.81, 0.83, 0.83, 0.84, and 0.90 when using the EEL-enhanced images (P = 0.003, P= 0.004, P=0.08, P = 0.12, and P = 0.23, respectively). EEL-enhanced IVOCT analysis was associated with a lower EEL-area measurement absolute error for fibroatheromas, mixed plaques, and all pooled plaques (P= 0.006, P = 0.02, and P <0.001, respectively). Compared with standard IVOCT, the EELenhanced IVOCT images had a higher sensitivity (79% vs. 28%, P < 0.001) and specificity (98% vs. 85%, P=0.03) for plaques with an IVUS PB >= 70%. Conclusion EEL-enhanced IVOCT can be used to reliably measure PB in all types of coronary atherosclerotic lesions, including fibroatheromas and mixed plaques.
引用
收藏
页码:640 / +
页数:13
相关论文
共 50 条
  • [21] Use of Intravascular Lithotripsy in Calcium Management: Comparison of Intravascular Ultrasound and Optical Coherence Tomography Guidance
    Bhattacharyya, Debdatta
    Kar, Ayan
    Agarwal, Kishan Kumar
    Goswami, Snehil
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (14) : S213 - S215
  • [22] Intravascular ultrasound versus optical coherence tomography
    Hajar, Rachel
    HEART VIEWS, 2019, 20 (01): : 35 - 36
  • [23] The relationship between intravascular ultrasound (IVUS) plaque burden and lesion characteristics by Optical Coherence Tomography (OCT): a multimodality imaging study
    Pena, Jacobo
    Vengrenyuk, Yuliya
    Baber, Usman
    Kovacic, Jason
    Sharma, Samin K.
    Kini, Annapoorna
    Narula, Jagat
    Moreno, Pedro R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B148 - B148
  • [24] Safety of optical coherence tomography in daily practice: a comparison with intravascular ultrasound
    van der Sijde, Johannes N.
    Karanasos, Antonios
    van Ditzhuijzen, Nienke S.
    Okamura, Takayuki
    van Geuns, Robert-Jan
    Valgimigli, Marco
    Ligthart, Jurgen M. R.
    Witberg, Karen T.
    Wemelsfelder, Saskia
    Fam, Jiang Ming
    Zhang, BuChun
    Diletti, Roberto
    de Jaegere, Peter P.
    van Mieghem, Nicolas M.
    van Soest, Gijs
    Zijlstra, Felix
    van Domburg, Ron T.
    Regar, Evelyn
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (04) : 467 - 474
  • [25] CLINICAL SIGNIFICANCE OF PLAQUE RUPTURE AND VASCULAR REMODELING IN ACUTE MYOCARDIAL INFARCTION ASSESSED BY OPTICAL COHERENCE TOMOGRAPHY AND INTRAVASCULAR ULTRASOUND
    Hoshino, Masahiro
    Yonetsu, Taishi
    Kanaji, Yoshihisa
    Usui, Eisuke
    Hada, Masahiro
    Ohya, Hiroaki
    Sumino, Yohei
    Hamaya, Rikuta
    Lee, Tetsumin
    Kanno, Yoshinori
    Fukuda, Tadashi
    Kakuta, Tsunekazu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1385 - 1385
  • [26] Intravascular Coronary Plaque Characterization Using Hybrid Intravascular Ultrasound and Optical Coherence Tomography: A Preliminary Study Based on User Interpretation Compared With Histology Reference
    Li, Brian
    Alves, Natasha
    Weyers, Jill
    Harduar, Mark
    Kayode, Folake
    Barritt, Nicole
    Courtney, Brian
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B356 - B356
  • [27] Impact of multiple ballooning on coronary lesions as assessed by optical coherence tomography and intravascular ultrasound
    Kanzaki, Yusuke
    Ueki, Yasushi
    Sunohara, Daisuke
    Okina, Yoshiteru
    Nomi, Hidetomo
    Machida, Keisuke
    Kashiwagi, Daisuke
    Yoda, Hidetsugu
    Maruyama, Shusaku
    Nagae, Ayumu
    Kato, Tamon
    Saigusa, Tatsuya
    Dijkstra, Jouke
    Ebisawa, Soichiro
    Kuwahara, Koichiro
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 104 (05) : 945 - 951
  • [28] Potential "Intraplaque Hemorrhage" Pattern Assessed by Combined Intravascular Ultrasound and Optical Coherence Tomography
    Lee, Tetsumin
    Mintz, Gary
    Matsumura, Mitsuaki
    Hoshino, Masahiro
    Usui, Eisuke
    Kanaji, Yoshihisa
    Murai, Tadashi
    Yonetsu, Taishi
    Kakuta, Tsunekazu
    Maehara, Akiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B21 - B21
  • [29] Retrospective Respiratory Gating for Intravascular Ultrasound/Intravascular Optical Coherence Tomography Images
    Zheng, Sun
    Yue, Huang
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (05) : 1212 - 1217
  • [30] DISCORDANCE OF LIPID RICH PLAQUE DIAGNOSIS BETWEEN OPTICAL COHERENCE TOMOGRAPHY AND INTRAVASCULAR ULTRASOUND
    Lee, Tetsumin
    Mintz, Gary
    Usui, Eisuke
    Hoshino, Masahiro
    Kanaji, Yoshihisa
    Murai, Tadashi
    Yonetsu, Taishi
    Kakuta, Tsunekazu
    Maehara, Akiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1299 - 1299