Zeolite-modified paraffin-impregnated graphite electrode

被引:29
|
作者
Walcarius, A [1 ]
机构
[1] Univ Nancy 1, CNRS, UMR 7564, Lab Chim Phys & Microbiol Environm, F-54600 Villers Les Nancy, France
关键词
zeolite-modified electrode; PIGE; ion exchange; lead; PbS; voltammetry;
D O I
10.1007/s10008-005-0020-z
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This paper describes a new kind of zeolite-modified electrodes (ZMEs) based on the physical immobilization of zeolite particles onto the surface of paraffin-impregnated graphite electrodes (PIGEs). Their electrochemical behavior was first evaluated by ion-exchange voltammetry using methylviologen as a model redox probe, indicating better performance in comparison to the corresponding zeolite-modified carbon paste electrodes. The zeolite-modified-PIGEs were then applied to the study of lead(II)-loaded zeolites to monitor their reaction with sulfide ions at various sulfidation levels. Both Pb(II) ions and PbS nanoparticles gave rise to well-defined voltammetric signals, but peak currents due to the more mobile Pb(II) ions were much higher than those recorded for PbS nanoparticles. This is due to the fact that Pb(II) ions underwent ion exchange for the electrolyte cation prior to the electron transfer whereas the PbS nanoparticles are immobilized in the microporous structure of the zeolite particles and thus less available for the redox reactions. Nevertheless, these signals were useful to discriminate between the various sulfidation levels, as ascertained by additional X-ray photoelectron spectroscopy measurements.
引用
收藏
页码:469 / 478
页数:10
相关论文
共 50 条
  • [31] Use of a zeolite-modified electrode for the study of the methylviologen-sodium ion-exchange in zeolite Y
    Walcarius, A
    Mariaulle, P
    Lamberts, L
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 463 (01): : 100 - 108
  • [32] Use of a zeolite-modified electrode for the study of the methylviologen-sodium ion-exchange in zeolite Y
    Lab. Chim. Phys. Pour l'E., U. Mixte Rech. UMR 7564, CNRS-U., F-54600 Villers-les-Nancy, France
    不详
    J Electroanal Chem, 1 (100-108):
  • [33] Zeolite-Modified Discriminating Gas Sensors
    Binions, Russell
    Davies, Helen
    Afonja, Ayo
    Dungey, Sheena
    Lewis, Dewi
    Williams, David E.
    Parkin, Ivan P.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2009, 156 (03) : J46 - J51
  • [34] Comparison of chloride and sulphate electrolytes in nickel electrodeposition on a paraffin impregnated graphite electrode
    Orinakova, R.
    Streckova, M.
    Trnkova, L.
    Rozik, R.
    Galova, M.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 594 (02) : 152 - 159
  • [35] Zeolite-modified electrodes in electroanalytical chemistry
    Walcarius, A
    ANALYTICA CHIMICA ACTA, 1999, 384 (01) : 1 - 16
  • [36] Zeolite-modified electrodes with analytical applications
    Muresan, Liana Maria
    PURE AND APPLIED CHEMISTRY, 2011, 83 (02) : 325 - 343
  • [37] PREPARATION OF POLYPYRROLE BY DIRECT ELECTROCHEMICAL OXIDATION OF PYRROLE ON PARAFFIN IMPREGNATED GRAPHITE ELECTRODE
    Filkusova, Maria
    Orinakova, Renata
    Markusova, Kvetoslava
    Koval', Karol
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2011, 76 (12) : 1931 - 1954
  • [38] VOLTAMMETRIC RESPONSE OF ZEOLITE-MODIFIED ELECTRODES
    SHAW, BR
    CREASY, KE
    LANCZYCKI, CJ
    SARGEANT, JA
    TIRHADO, M
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (04) : 869 - 876
  • [39] Application of LTA zeolite-modified electrode for sensitive detection of retinoic acid in tap water
    Jiang, Yuying
    Yifeng, E.
    Wei, Pengyan
    Wang, Jia
    Chen, Peng
    Wang, Lei
    Krenzel, Thomas F.
    Qian, Kun
    Tong, Xiyuan
    RSC ADVANCES, 2023, 13 (05) : 3364 - 3370
  • [40] Zeolite-modified cantilevers for the sensing of nitrotoluene vapors
    Urbiztondo, M. A.
    Pellejero, I.
    Villarroya, M.
    Sese, J.
    Pina, M. P.
    Dufour, I.
    Santamaria, J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (02): : 608 - 616