Flow-injection chemiluminescence simultaneous determination of cobalt(II) and copper(II) using partial least squares calibration

被引:60
|
作者
Li, BX [1 ]
Wang, DM [1 ]
Lv, HG [1 ]
Zhang, ZJ [1 ]
机构
[1] Shaanxi Normal Univ, Sch Chem & Mat Sci, Dept Chem, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
flow-injection; chemiluminescence; partial least squares; simultaneous determination; Co2+ and Cu2+;
D O I
10.1016/j.talanta.2005.09.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection chemiluminescence (CL) system is proposed for simultaneous determination of Co2+ and Cu2+ using partial least squares (PLS) calibration. This method is based on the fact that both Co2+ and Cu2+ catalyse the CL reaction of luminol-H2O2, and that their kinetic characteristics of Co2+ and Cu2+ are significantly different in the luminol-H2O2 system. The CL intensity was measured and recorder at different reaction times of luminol-H2O2-Co2+-Cu2+, and the obtained data were processed by the chemometric approach of partial least squares. The experimental calibration set was composed of 16 sample solutions using an orthogonal calibration design for two component mixtures. The proposed method offers the potential advantages of high sensitivity, simplicity and rapidity for Co2+ and Cu2+ determination, and was successfully applied to the simultaneous determination of both analytes in real water sample. The present paper demonstrated that the simultaneous determination of two metal ions without any prior separation has been possible using flow-injection CL system. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [31] Flow-injection chemiluminescence determination of captopril using on-line electrogenerated silver(II) as the oxidant
    Li, BX
    Zhang, ZJ
    Wu, ML
    MICROCHEMICAL JOURNAL, 2001, 70 (02) : 85 - 91
  • [32] Flow-injection chemiluminescence determination of sulfite using on-line electrogenerated silver(II) as the oxidant
    Li, BX
    Zhang, ZJ
    Wu, ML
    ANALYTICA CHIMICA ACTA, 2001, 432 (02) : 311 - 316
  • [33] COBALT(II)-CATALYZED CHEMILUMINESCENCE IN A DIOCTADECYLDIMETHYLAMMONIUM CHLORIDE BILAYER MEMBRANOUS MEDIUM FOR THE FLOW-INJECTION DETERMINATION OF PHENYLPYRUVIC ACID
    KISHIDA, M
    MAKITA, Y
    SUZUKI, T
    YAMADA, M
    HOBO, T
    ANALYTICAL CHEMISTRY, 1991, 63 (20) : 2301 - 2305
  • [34] Flow-injection analysis of cobalt(II) utilizing enhanced lophine chemiluminescence with hydroxylammonium chloride
    Nakashima, K
    Yamasaki, H
    Shimoda, R
    Kuroda, N
    Akiyama, S
    Baeyens, WRG
    BIOMEDICAL CHROMATOGRAPHY, 1997, 11 (02) : 63 - 64
  • [35] Resolution of ofloxacin-ciprofloxacin and ofloxacin-norfloxacin binary mixtures by flow-injection chemiluminescence in combination with partial least squares multivariate calibration
    Murillo, J. A.
    Molina, A. Alanon
    de la Pena, A. Munoz
    Meras, I. Duran
    Giron, A. Jimenez
    JOURNAL OF FLUORESCENCE, 2007, 17 (05) : 481 - 491
  • [36] EVALUATION OF MULTICOMPONENT FLOW-INJECTION ANALYSIS DATA BY USE OF A PARTIAL LEAST-SQUARES CALIBRATION METHOD
    HERNANDEZ, O
    JIMENEZ, AI
    JIMENEZ, F
    ARIAS, JJ
    ANALYTICA CHIMICA ACTA, 1995, 310 (01) : 53 - 61
  • [37] Simultaneous spectrophotometric determination of copper(II) and nickel(II) as complexes with sodium diethyldithiocarbamate in an anionic micellar medium using partial least-squares regression
    Kompany-Zareh, M
    Massoumi, A
    Tavallali, H
    MICROCHEMICAL JOURNAL, 1999, 63 (02) : 257 - 265
  • [38] FLOW-INJECTION DETERMINATION OF IRON(II)
    GUREV, IA
    LAZAREVA, OP
    ZYUZINA, LF
    JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 48 (03) : 363 - 365
  • [39] DETERMINATION OF COPPER(II) AT SUBPICOGRAM LEVEL BY FLOW-INJECTION METHOD USING MICELLAR ENHANCED CHEMILUMINESCENCE OF 1,10-PHENANTHROLINE
    ISHII, M
    YAMADA, M
    SUZUKI, S
    BUNSEKI KAGAKU, 1986, 35 (04) : 373 - 378
  • [40] PARTIAL LEAST-SQUARES RESOLUTION OF MULTIANALYTE FLOW-INJECTION DATA
    MACLAURIN, P
    WORSFOLD, PJ
    NORMAN, P
    CRANE, M
    ANALYST, 1993, 118 (06) : 617 - 622