Gait speed using powered robotic exoskeletons after spinal cord injury: a systematic review and correlational study

被引:147
|
作者
Louie, Dennis R. [1 ,2 ,3 ]
Eng, Janice J. [1 ,2 ,3 ,4 ,5 ]
Lam, Tania [1 ,4 ]
机构
[1] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[2] Rehabil Res Program, Vancouver, BC V5Z 2G9, Canada
[3] Vancouver Coastal Hlth Res Inst, Vancouver, BC, Canada
[4] Int Collaborat Repair Discoveries, Vancouver, BC, Canada
[5] Univ British Columbia, Dept Phys Therapy, Vancouver, BC V6T 1Z3, Canada
基金
加拿大健康研究院;
关键词
WALKING; REHABILITATION; ORTHOSIS; AMBULATION; COMPLICATIONS; INDIVIDUALS; POPULATION; LEVEL;
D O I
10.1186/s12984-015-0074-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Powered robotic exoskeletons are an emerging technology of wearable orthoses that can be used as an assistive device to enable non-ambulatory individuals with spinal cord injury (SCI) to walk, or as a rehabilitation tool to improve walking ability in ambulatory individuals with SCI. No studies to date have systematically reviewed the literature on the efficacy of powered exoskeletons on restoring walking function. Our objective was to systematically review the literature to determine the gait speed attained by individuals with SCI when using a powered exoskeleton to walk, factors influencing this speed, and characteristics of studies involving a powered exoskeleton (e.g. inclusion criteria, screening, and training processes). A systematic search in computerized databases was conducted to identify articles that reported on walking outcomes when using a powered exoskeleton. Individual gait speed data from each study was extracted. Pearson correlations were performed between gait speed and 1) age, 2) years post-injury, 3) injury level, and 4) number of training sessions. Fifteen articles met inclusion criteria, 14 of which investigated the powered exoskeleton as an assistive device for non-ambulatory individuals and one which used it as a training intervention for ambulatory individuals with SCI. The mean gait speed attained by non-ambulatory participants (n = 84) while wearing a powered exoskeleton was 0.26 m/s, with the majority having a thoracic-level motor-complete injury. Twelve articles reported individual data for the non-ambulatory participants, from which a positive correlation was found between gait speed and 1) age (r = 0.27, 95 % CI 0.02-0.48, p = 0.03, 63 participants), 2) injury level (r = 0.27, 95 % CI 0.02-0.48, p = 0.03, 63 participants), and 3) training sessions (r = 0.41, 95 % CI 0.16-0.61, p = 0.002, 55 participants). In conclusion, powered exoskeletons can provide non-ambulatory individuals with thoracic-level motor-complete SCI the ability to walk at modest speeds. This speed is related to level of injury as well as training time.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A Systematic Review of the Determinants of Implementation of a Locomotor Training Program Using a Powered Exoskeleton for Individuals with a Spinal Cord Injury
    Charette, Caroline
    Dery, Julien
    Blanchette, Andreanne K.
    Faure, Celine
    Routhier, Francois
    Bouyer, Laurent J.
    Lamontagne, Marie-Eve
    CLINICAL REHABILITATION, 2023, 37 (08) : 1119 - 1138
  • [42] Gait training after spinal cord injury: safety, feasibility and gait function following 8 weeks of training with the exoskeletons from Ekso Bionics
    Carsten Bach Baunsgaard
    Ulla Vig Nissen
    Anne Katrin Brust
    Angela Frotzler
    Cornelia Ribeill
    Yorck-Bernhard Kalke
    Natacha León
    Belén Gómez
    Kersti Samuelsson
    Wolfram Antepohl
    Ulrika Holmström
    Niklas Marklund
    Thomas Glott
    Arve Opheim
    Jesus Benito
    Narda Murillo
    Janneke Nachtegaal
    Willemijn Faber
    Fin Biering-Sørensen
    Spinal Cord, 2018, 56 : 106 - 116
  • [43] Knowledge Gaps in Biophysical Changes After Powered Robotic Exoskeleton Walking by Individuals With Spinal Cord Injury-A Scoping Review
    Yip, Christopher C. H.
    Lam, Chor-Yin
    Cheung, Kenneth M. C.
    Wong, Yat Wa
    Koljonen, Paul A.
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [44] Gait training after spinal cord injury: safety, feasibility and gait function following 8 weeks of training with the exoskeletons from Ekso Bionics
    Baunsgaard, Carsten Bach
    Nissen, Ulla Vig
    Brust, Anne Katrin
    Frotzler, Angela
    Ribeill, Cornelia
    Kalke, Yorck-Bernhard
    Leon, Natacha
    Gomez, Belen
    Samuelsson, Kersti
    Antepohl, Wolfram
    Holmstrom, Ulrika
    Marklund, Niklas
    Glott, Thomas
    Opheim, Arve
    Benito, Jesus
    Murillo, Narda
    Nachtegaal, Janneke
    Faber, Willemijn
    Biering-Sorensen, Fin
    SPINAL CORD, 2018, 56 (02) : 106 - 116
  • [45] A Systematic Review of Intensive Cardiopulmonary Management after Spinal Cord Injury
    Casha, Steven
    Christie, Sean
    JOURNAL OF NEUROTRAUMA, 2011, 28 (08) : 1479 - 1495
  • [46] SYSTEMATIC REVIEW OF UROLOGICAL FOLLOW UP AFTER SPINAL CORD INJURY
    Cameron, A. P.
    Schomer, K.
    Rodriguez, G.
    NEUROUROLOGY AND URODYNAMICS, 2011, 30 (06) : 835 - 836
  • [47] SYSTEMATIC REVIEW OF UROLOGICAL FOLLOW UP AFTER SPINAL CORD INJURY
    Cameron, Anne
    Schomer, Katherine
    Rodriguez, Gianna
    NEUROUROLOGY AND URODYNAMICS, 2011, 30 (02) : 275 - 275
  • [48] SYSTEMATIC REVIEW OF UROLOGICAL FOLLOW UP AFTER SPINAL CORD INJURY
    Cameron, Anne P.
    Schomer, Katherine
    Rodriguez, Gianna
    JOURNAL OF UROLOGY, 2011, 185 (04): : E5 - E5
  • [49] A Systematic Review of the Management of Autonomic Dysreflexia After Spinal Cord Injury
    Krassioukov, Andrei
    Warburton, Darren E.
    Teasell, Robert
    Eng, Janice J.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (04): : 682 - 695
  • [50] Colostomy and quality of life after spinal cord injury: systematic review
    Waddell, O.
    McCombie, A.
    Frizelle, F.
    BJS OPEN, 2020, 4 (06): : 1054 - 1061