Towards clinical application: prompt gamma imaging of passively scattered proton fields with a knife-edge slit camera

被引:19
|
作者
Priegnitz, M. [1 ]
Barczyk, S. [2 ,3 ,4 ,5 ]
Nenoff, L. [2 ,3 ]
Golnik, C. [2 ,3 ]
Keitz, I. [2 ,3 ]
Werner, T. [2 ,3 ]
Mein, S. [2 ,3 ]
Smeets, J. [6 ]
Stappen, F. Vander [6 ]
Janssens, G. [6 ]
Hotoiu, L. [6 ]
Fiedler, F. [1 ]
Prieels, D.
Enghardt, W. [2 ,3 ,4 ,5 ,7 ,8 ,9 ]
Pausch, G. [2 ,3 ]
Richter, C. [2 ,3 ,4 ,5 ,7 ,8 ,9 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Inst Radiat Phys, Bautzner Landstr 400, D-01328 Dresden, Germany
[2] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, Fac Med, OncoRay Natl Ctr Radiat Res Oncol, Dresden, Germany
[3] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, Univ Hosp Carl Gustav Carus, Dresden, Germany
[4] Tech Univ Dresden, Fac Med, Dept Radiat Oncol, Dresden, Germany
[5] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dresden, Germany
[6] Ion Beam Applicat SA, Chemin Cyclotron 3, B-1348 Louvain La Neuve, Belgium
[7] Helmholtz Zentrum Dresden Rossendorf, Inst Radiooncol, Bautzner Landstr 400, D-01328 Dresden, Germany
[8] German Canc Consortium DKTK, Dresden, Germany
[9] German Canc Res Ctr, Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 22期
关键词
proton therapy; prompt gamma imaging; range verification; slit camera; double scattering; passively scattered proton treatment; RANGE VERIFICATION; COMPTON CAMERA; PENCIL BEAMS; THERAPY; DESIGN; SYSTEM; RAYS; FEASIBILITY;
D O I
10.1088/0031-9155/61/22/7881
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prompt gamma-ray imaging with a knife-edge shaped slit camera provides the possibility of verifying proton beam range in tumor therapy. Dedicated experiments regarding the characterization of the camera system have been performed previously. Now, we aim at implementing the prototype into clinical application of monitoring patient treatments. Focused on this goal of translation into clinical operation, we systematically addressed remaining challenges and questions. We developed a robust energy calibration routine and corresponding quality assurance protocols. Furthermore, with dedicated experiments, we determined the positioning precision of the system to 1.1 mm (2 sigma). For the first time, we demonstrated the application of the slit camera, which was intentionally developed for pencil beam scanning, to double scattered proton beams. Systematic experiments with increasing complexity were performed. It was possible to visualize proton range shifts of 2-5 mm with the camera system in phantom experiments in passive scattered fields. Moreover, prompt gamma-ray profiles for single iso-energy layers were acquired by synchronizing time resolved measurements to the rotation of the range modulator wheel of the treatment system. Thus, a mapping of the acquired profiles to different anatomical regions along the beam path is feasible and additional information on the source of potential range shifts can be obtained. With the work presented here, we show that an application of the slit camera in clinical treatments is possible and of potential benefit.
引用
收藏
页码:7881 / 7905
页数:25
相关论文
共 28 条
  • [1] Prompt gamma imaging of passively shaped proton fields with a knife-edge slit camera
    Priegnitz, M.
    Barczyk, S.
    Keitz, I.
    Mein, S.
    Stappen, F. V.
    Janssens, G.
    Hotoiu, L.
    Smeets, J.
    Fiedler, F.
    Prieels, D.
    Enghardt-, W.
    Pausch, G.
    Richter, C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S86 - S87
  • [2] First clinical application of a prompt gamma based in vivo proton range verification using a knife-edge slit camera
    Richter, C.
    Pausch, G.
    Barczyk, S.
    Priegnitz, M.
    Keitz, I.
    Thiele, J.
    Smeets, J.
    Vander Stappen, F.
    Bombelli, L.
    Fiorini, C.
    Hotoiu, L.
    Perali, I.
    Prieels, D.
    Enghardt, W.
    Baumann, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S89 - S90
  • [3] Measurement of prompt gamma profiles in inhomogeneous targets with a knife-edge slit camera during proton irradiation
    Priegnitz, M.
    Helmbrecht, S.
    Janssens, G.
    Perali, I.
    Smeets, J.
    Stappen, F. Vander
    Sterpin, E.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12): : 4849 - 4871
  • [4] Experimental Comparison of Knife-Edge and Multi-Parallel Slit Collimators for Prompt Gamma Imaging of Proton Pencil Beams
    Smeets, Julien
    Roellinghoff, Frauke
    Janssens, Guillaume
    Perali, Irene
    Celani, Andrea
    Fiorini, Carlo
    Freud, Nicolas
    Testa, Etienne
    Prieels, Damien
    FRONTIERS IN ONCOLOGY, 2016, 6
  • [5] Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters
    Lopes, Patricia Cambraia
    Clementel, Enrico
    Crespo, Paulo
    Henrotin, Sebastien
    Huizenga, Jan
    Janssens, Guillaume
    Parodi, Katia
    Prieels, Damien
    Roellinghoff, Frauke
    Smeets, Julien
    Stichelbaut, Frederic
    Schaart, Dennis R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 6063 - 6085
  • [6] Characterization and Modeling of Knife-Edge Slit Collimator Response for MeV Prompt Gamma Photons in Proton Therapy Monitoring
    Lu, Wenzhuo
    Fan, Peng
    Liu, Yaqiang
    Wu, Zhaoxia
    Wang, Shi
    Ma, Tianyu
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [7] Accurate Modeling of Multi Knife-edge Slit Collimator System Response for MeV Prompt Gamma Photons in Proton Therapy Monitoring
    Zhang, Debin
    Fan, Peng
    Lu, Wenzhuo
    Wang, Shi
    Xia, Yan
    Wu, Zhaoxia
    Liu, Yaqiang
    Ma, Tianyu
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [8] Analytical modeling and Monte Carlo simulations of multi-parallel slit and knife-edge slit prompt gamma cameras
    Huisman, B. F. B.
    Munoz, E.
    Dauvergne, D.
    Letang, J. M.
    Sarrut, D.
    Testa, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [9] Prompt-gamma fall-off estimation with C-ion irradiation at clinical energies, using a knife-edge slit camera: A Monte Carlo study
    Missaglia, Andrea
    Bourkadi-Idrissi, Aicha
    Casamichiela, Francesco
    Mazzucconi, Davide
    Carminati, Marco
    Agosteo, Stefano
    Fiorini, Carlo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 107
  • [10] Prompt Gamma Imaging with a Multi-Knife-Edge Slit Collimator: Evaluation for Use in Proton Beam Range Verification
    Ready, J.
    Negut, V.
    Mihailescu, L.
    Vetter, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3717 - 3717