Prompt-gamma fall-off estimation with C-ion irradiation at clinical energies, using a knife-edge slit camera: A Monte Carlo study

被引:9
|
作者
Missaglia, Andrea [1 ]
Bourkadi-Idrissi, Aicha [1 ,2 ]
Casamichiela, Francesco [3 ]
Mazzucconi, Davide [2 ,3 ]
Carminati, Marco [1 ,2 ]
Agosteo, Stefano [2 ,3 ]
Fiorini, Carlo [1 ,2 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, Via Ponzio 34-5, I-20133 Milan, Italy
[2] INFN, Sez Milano, Via Giovanni Celoria 16, I-20133 Milan, Italy
[3] Politecn Milan, Dipartimento Energia, Via Lambruschini 4, I-20156 Milan, Italy
关键词
Prompt Gamma Imaging; Carbon-ion Radiation Therapy; Feasibility study; Monte Carlo simulations; FLUKA; PROTON RANGE VERIFICATION; PARTICLE THERAPY; RAY EMISSION;
D O I
10.1016/j.ejmp.2023.102554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In-vivo range verification has been a hot topic in particle therapy since two decades. Many efforts have been done for proton therapy, while fewer studies were conducted considering a beam of carbon ions. In the present work, a simulation study was performed to show whether it is possible to measure the prompt -gamma fall-off inside the high neutron background typical of carbon-ion irradiation, using a knife-edge slit camera. In addition to this, we wanted to estimate the uncertainty in retrieving the particle range in the case of a pencil beam of C-ions at clinically relevant energy of 150 MeuV.Methods: For these purposes, the Monte Carlo code FLUKA was adopted for simulations and three different analytical methods were implemented to get the accuracy in the range retrieval of the simulated set-up.Results: The analysis of simulation data has brought to the promising and desired precision of about 4 mm in the determination of the dose profile fall-off in case of a spill irradiation, for which all the three cited methods were coherent in their predictions.Conclusions: The Prompt Gamma Imaging technique should be further studied as a tool to reduce range uncertainties affecting carbon ion radiation therapy.
引用
收藏
页数:10
相关论文
共 6 条
  • [1] Analytical modeling and Monte Carlo simulations of multi-parallel slit and knife-edge slit prompt gamma cameras
    Huisman, B. F. B.
    Munoz, E.
    Dauvergne, D.
    Letang, J. M.
    Sarrut, D.
    Testa, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [2] Derivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study
    Malelizadeh, Etesam
    Rajabi, Hossein
    Fiorina, Elisa
    Kalantari, Faraz
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2021, 29 (02): : 86 - 92
  • [3] Measurement of prompt gamma profiles in inhomogeneous targets with a knife-edge slit camera during proton irradiation
    Priegnitz, M.
    Helmbrecht, S.
    Janssens, G.
    Perali, I.
    Smeets, J.
    Stappen, F. Vander
    Sterpin, E.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12): : 4849 - 4871
  • [4] First clinical application of a prompt gamma based in vivo proton range verification using a knife-edge slit camera
    Richter, C.
    Pausch, G.
    Barczyk, S.
    Priegnitz, M.
    Keitz, I.
    Thiele, J.
    Smeets, J.
    Vander Stappen, F.
    Bombelli, L.
    Fiorini, C.
    Hotoiu, L.
    Perali, I.
    Prieels, D.
    Enghardt, W.
    Baumann, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S89 - S90
  • [5] Towards clinical application: prompt gamma imaging of passively scattered proton fields with a knife-edge slit camera
    Priegnitz, M.
    Barczyk, S.
    Nenoff, L.
    Golnik, C.
    Keitz, I.
    Werner, T.
    Mein, S.
    Smeets, J.
    Stappen, F. Vander
    Janssens, G.
    Hotoiu, L.
    Fiedler, F.
    Prieels, D.
    Enghardt, W.
    Pausch, G.
    Richter, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (22): : 7881 - 7905
  • [6] Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters
    Lopes, Patricia Cambraia
    Clementel, Enrico
    Crespo, Paulo
    Henrotin, Sebastien
    Huizenga, Jan
    Janssens, Guillaume
    Parodi, Katia
    Prieels, Damien
    Roellinghoff, Frauke
    Smeets, Julien
    Stichelbaut, Frederic
    Schaart, Dennis R.