Development of a Standard Reference Material for Metabolomics Research

被引:95
|
作者
Phinney, Karen W. [1 ]
Ballihaut, Guillaume [2 ]
Bedner, Mary [2 ]
Benford, Brandi S. [2 ]
Camara, Johanna E. [2 ]
Christopher, Steven J. [2 ]
Davis, W. Clay [2 ]
Dodder, Nathan G. [2 ]
Eppe, Gauthier [2 ]
Lang, Brian E. [3 ]
Long, Stephen E. [2 ]
Lowenthal, Mark S. [1 ]
McGaw, Elizabeth A. [2 ]
Murphy, Karen E. [2 ]
Nelson, Bryant C. [3 ]
Prendergast, Jocelyn L. [2 ]
Reiner, Jessica L. [2 ]
Rimmer, Catherine A. [2 ]
Sander, Lane C. [2 ]
Schantz, Michele M. [2 ]
Sharpless, Katherine E. [2 ]
Sniegoski, Lorna T. [2 ]
Tai, Susan S. -C. [2 ]
Thomas, Jeanice B. [2 ]
Vetter, Thomas W. [2 ]
Welch, Michael J. [2 ]
Wise, Stephen A. [2 ]
Wood, Laura J. [2 ]
Guthrie, William F. [4 ]
Hagwood, Charles R. [4 ]
Leigh, Stefan D. [4 ]
Yen, James H. [4 ]
Zhang, Nien-Fan [4 ]
Chaudhary-Webb, Madhu [5 ]
Chen, Huiping [5 ]
Fazili, Zia [5 ]
LaVoie, Donna J. [5 ]
McCoy, Leslie F. [5 ]
Momin, Shahzad S. [5 ]
Paladugula, Neelima [5 ]
Pendergrast, Elizabeth C. [5 ]
Pfeiffer, Christine M. [5 ]
Powers, Carissa D. [5 ]
Rabinowitz, Daniel [5 ]
Rybak, Michael E. [5 ]
Schleicher, Rosemary L. [5 ]
Toombs, Bridgette M. H. [5 ]
Xu, Mary [5 ]
Zhang, Mindy [5 ]
Castle, Arthur L. [6 ]
机构
[1] NIST, Biomol Measurement Div, Gaithersburg, MD 20899 USA
[2] NIST, Div Chem Sci, Gaithersburg, MD 20899 USA
[3] NIST, Biosyst & Biomat Div, Gaithersburg, MD 20899 USA
[4] NIST, Stat Engn Div, Gaithersburg, MD 20899 USA
[5] Ctr Dis Control & Prevent, Div Sci Lab, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
[6] NIDDK, NIH, Bethesda, MD 20892 USA
关键词
MASS-SPECTROMETRY; HUMAN PLASMA; ACID-METABOLISM; HUMAN URINE; HPLC-MS; METABONOMICS; DISEASE; PERFORMANCE; DIAGNOSIS; RISK;
D O I
10.1021/ac402689t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health (NTH), has developed a Standard Reference Material (SRM) to support technology development in metabolomics research. SRM 1950 Metabolites in Human Plasma is intended to have metabolite concentrations that are representative of those found in adult human plasma. The plasma used in the preparation of SRM 1950 was collected from both male and female donors, and donor ethnicity targets were selected based upon the ethnic makeup of the U.S. population. Metabolomics research is diverse in terms of both instrumentation and scientific goals. This SRM was designed to apply broadly to the field, not toward specific applications. Therefore, concentrations of approximately 100 analytes, including amino acids, fatty acids, trace elements, vitamins, hormones, selenoproteins, clinical markers, and perfluorinated compounds (PFCs), were determined. Value assignment measurements were performed by NIST and the Centers for Disease Control and Prevention (CDC). SRM 1950 is the first reference material developed specifically for metabolomics research.
引用
收藏
页码:11732 / 11738
页数:7
相关论文
共 50 条
  • [21] Development of an improved standard reference material for folate vitamers in human serum
    Camara, Johanna E.
    Pritchett, Jeanita S.
    Daniels, Yasmine C.
    Bedner, Mary
    Nelson, Michael A.
    Lowenthal, Mark S.
    Fazili, Zia
    Pfeiffer, Christine M.
    Phinney, Karen W.
    Sharpless, Katherine E.
    Sander, Lane C.
    Lippa, Katrice A.
    Yen, James H.
    Kuszak, Adam J.
    Wise, Stephen A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (05) : 809 - 821
  • [22] Development of an improved standard reference material for folate vitamers in human serum
    Johanna E. Camara
    Jeanita S. Pritchett
    Yasmine C. Daniels
    Mary Bedner
    Michael A. Nelson
    Mark S. Lowenthal
    Zia Fazili
    Christine M. Pfeiffer
    Karen W. Phinney
    Katherine E. Sharpless
    Lane C. Sander
    Katrice A. Lippa
    James H. Yen
    Adam J. Kuszak
    Stephen A. Wise
    Analytical and Bioanalytical Chemistry, 2023, 415 : 809 - 821
  • [23] Advances in Huntington's disease diagnostics: development of a standard reference material
    Levin, Barbara C.
    Ritchie, Kristy L.
    Jakupciak, John P.
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2006, 6 (04) : 587 - 596
  • [24] Development of a house dust standard reference material for the determination of organic contaminants
    Poster, Dianne L.
    Kucklick, John R.
    Schantz, Michele M.
    Vander Pol, Stacy S.
    Leigh, Stefan D.
    Wiset, Stephen A.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (08) : 2861 - 2867
  • [26] Peanut butter is a standard reference material
    不详
    CHEMICAL & ENGINEERING NEWS, 2003, 81 (22) : 48 - 48
  • [27] STANDARD WOOL FABRIC AS A REFERENCE MATERIAL
    HILADO, CJ
    CUMMING, HJ
    JOURNAL OF COMBUSTION TOXICOLOGY, 1977, 4 (04): : 454 - 463
  • [28] A Standard Reference Material for Lung CT
    Chen-Mayer, H.
    Levine, Z.
    Zimmerman, B.
    Mason, D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] STANDARD REFERENCE MATERIAL OF FLUORITE FM
    DEMPIR, J
    VALCHA, Z
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1982, 6 (01): : 13 - 16
  • [30] Reference-standard material qualification
    Browne, David
    Pharmaceutical Technology, 2009, 33 (04) : 66 - 73