In vitro study on the dimensional accuracy of selected materials for monophase elastic impression making

被引:0
|
作者
Piwowarczyk, A [1 ]
Ottl, P [1 ]
Büchler, A [1 ]
Lauer, HC [1 ]
Hoffmann, A [1 ]
机构
[1] Goethe Univ Frankfurt, Sch Dent, Dept Prosthet Dent, D-60590 Frankfurt, Germany
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluated the dimensional accuracy of various impression materials for monophase elastic impression making. To isolate this parameter, a direct measurement of the impressions was made without taking the model material into consideration. Materials and Methods: A total of eight materials were tested; six impression materials were addition-curing silicones, and two were polyether impression materials. All materials were processed according to the manufacturers' instructions. A specially developed precision mold made of stainless steel served as a basis for measuring the elastomeric impression materials. Using a stereomicroscope at a temperature of 23.0 +/- 1.0degreesC and with a precision linear adjustment and lathe, sights were set on the marking points of customized posts. The measurement was performed after the earliest time possible for fabricating the model according to the manufacturer (time 1) and after 90 minutes (time 2). In a one-way analysis of variance, multiple average comparisons of dimensional accuracy were made (Pless than or equal to.05) between the impression materials under investigation. Results: Under the conditions of this study, the impression materials tested demonstrated a very high dimensional accuracy. The arithmetic means of the dimensional changes ranged from -11 to 19 mum for both measuring times. Conclusion: Since as a rule, no significant dimensional changes occurred for the different impression materials between time 1 and time 2, this time interval for fabricating a model can be recommended.
引用
收藏
页码:168 / 174
页数:7
相关论文
共 50 条
  • [11] Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study
    Basapogu, Sreeramulu
    Pilla, Ajai
    Pathipaka, Suman
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (02) : ZC56 - ZC59
  • [12] COMPARISON OF DIMENSIONAL ACCURACY AND STABILITY OF ELASTOMERIC IMPRESSION MATERIALS
    WALLACE, SW
    SUWAY, NB
    EAMES, WB
    JOURNAL OF DENTAL RESEARCH, 1978, 57 : 79 - 79
  • [13] Dimensional accuracy of models from different impression materials
    Rodrigues, RCS
    Ribeiro, RF
    Antunes, RPA
    Mattos, MGC
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1152 - 1152
  • [14] Dimensional accuracy of epoxy resins and their compatibility with impression materials
    Chang, SK
    Chang, IT
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1145 - 1145
  • [15] The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
    Rutkunas, V.
    Bilius, V.
    Simonaitis, T.
    Auskalnis, L.
    Jurgilevicius, J.
    Akulauskas, M.
    JOURNAL OF DENTISTRY, 2022, 126
  • [16] Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    Lee, Heeje
    Ercoli, Carlo
    Funkenbusch, Paul D.
    Feng, Changyong
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02): : 107 - 113
  • [17] Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology
    Steinhaeuser-Andresen, Stefanie
    Detterbeck, Andreas
    Funk, Christoph
    Krumm, Michael
    Kasperl, Stefan
    Holst, Alexandra
    Hirschfelder, Ursula
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2011, 72 (02): : 111 - 124
  • [18] Working times of elastomeric impression materials determined by dimensional accuracy
    Tan, E
    Chai, J
    Wozniak, WT
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1996, 9 (02) : 188 - 196
  • [19] DIMENSIONAL ACCURACY OF COMBINED REVERSIBLE AND IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIALS
    SUPOWITZ, ML
    SCHNELL, RJ
    DYKEMA, RW
    GOODACRE, CJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1988, 59 (04): : 404 - 409
  • [20] DIMENSIONAL ACCURACY OF EPOXY-RESINS AND THEIR COMPATIBILITY WITH IMPRESSION MATERIALS
    AIACH, D
    MALONE, WFP
    SANDRIK, J
    JOURNAL OF PROSTHETIC DENTISTRY, 1984, 52 (04): : 500 - 504