A microfluidic lab-on-chip derivatisation technique for the measurement of gas phase formaldehyde

被引:22
|
作者
Pang, Xiaobing [2 ]
Lewis, Alastair C. [1 ]
机构
[1] Univ York, Natl Ctr Atmospher Sci, York YO10 5DD, N Yorkshire, England
[2] Univ York, Dept Chem, York YO10 5DD, N Yorkshire, England
基金
英国工程与自然科学研究理事会; 英国自然环境研究理事会;
关键词
TOTAL ANALYSIS SYSTEMS; CARBONYL-COMPOUNDS; ATMOSPHERIC FORMALDEHYDE; AIRBORNE CARBONYLS; CHROMATOGRAPHY; AIR; MICROEXTRACTION; PHOTOOXIDATION; SCRUBBER; SORBENT;
D O I
10.1039/c2ay25028d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic lab-on-chip derivatisation technique has been optimized to achieve a rapid, automated and sensitive determination of ambient gaseous formaldehyde when used in combination with GC-MS. The method used a Pyrex micro-reactor comprising three inlets and one outlet, gas and fluid splitting and combining channels, mixing junctions, and a 2.0 m long, 620 mm internal diameter reaction micro-channel. The micro-reactor integrated three functions, that of: (1) mixer and reactor, (2) heater, and (3) preconcentrator. The flow rates of the gas sample and derivatisation solution and the temperature of the micro-reactor were optimized to achieve a near real-time measurement with a rapid and high efficiency derivatisation step following gas sampling. The enhanced phase contact area-to-volume ratio and the high heat transfer rate in the micro-reactor resulted in a fast and high efficiency derivatisation reaction. Calibration showed good linearity in the range of 26 to 331 ppb with correlation coefficients R-2 = 0.988 and 0.997 for PFPH and PFBHA derivatives. For low gas phase formaldehyde mixing ratios (<26 ppb) the derivatisation solution could be repeatedly recycled through the chip enabling preconcentration of the derivative - hydrazone. The calibration curves for this recycling approach also showed good linearity from 4.0 to 26 ppb with method detection limits (MDLs) of 2.1 ppb and 1.1 ppb for PFPH and PFBHA derivatives. The feasibility of the technique was assessed using measurements of laboratory ambient air, with formaldehyde the predominant carbonyl compound at a 12.5 ppb level. The proof of principle experiments demonstrated the potential of the approach for on-line measurements of other carbonyls including acetaldehyde, acetone and propionaldehyde.
引用
收藏
页码:2013 / 2020
页数:8
相关论文
共 50 条
  • [1] A Microfluidic Packaging Technique for Lab-on-Chip Applications
    Ghafar-Zadeh, Ebrahim
    Sawan, Mohamad
    Therriault, Daniel
    IEEE TRANSACTIONS ON ADVANCED PACKAGING, 2009, 32 (02): : 410 - 416
  • [2] Lab-on-chip Microfluidic System for Single Cell Mass Measurement
    Rahman, Md. Habibur
    Ahmad, Ida Laila
    SayahKarajy, Mostafa
    Ahmad, Mohd Ridzuan
    Nakajima, Masahiro
    Fukuda, Toshio
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 672 - 676
  • [3] Microfluidic degasser for lab-on-chip devices
    Al-Adhami, Mustafa
    Gutierrez, Erick
    Andar, Abhay
    Rao, Govind
    Kostov, Iordan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [4] Monitoring microbial growth on a microfluidic lab-on-chip with electrochemical impedance spectroscopic technique
    Subhan Shaik
    Aarthi Saminathan
    Deepak Sharma
    Jagdish A Krishnaswamy
    D Roy Mahapatra
    Biomedical Microdevices, 2021, 23
  • [5] Monitoring microbial growth on a microfluidic lab-on-chip with electrochemical impedance spectroscopic technique
    Shaik, Subhan
    Saminathan, Aarthi
    Sharma, Deepak
    Krishnaswamy, Jagdish A.
    Mahapatra, D. Roy
    BIOMEDICAL MICRODEVICES, 2021, 23 (02)
  • [6] Identification of microfluidic two-phase flow patterns in lab-on-chip devices
    Yang, Zhaochu
    Dong, Tao
    Halvorsen, Einar
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 77 - 83
  • [7] Inkjet Printing for Applications in Microfluidic Lab-on-Chip Systems
    Beckert, Erik
    Pabst, Oliver
    Perelaer, Jolke
    Schubert, Ulrich S.
    Eberhardt, Ramona
    Tuennermann, Andreas
    NIP28: 28TH INTERNATIONAL CONFERENCE ON DIGITAL PRINTING TECHNOLOGIES / DIGITAL FABRICATION 2012, 2012, : 557 - 560
  • [8] Development of a microfluidic design for an automatic lab-on-chip operation
    Nitipon Puttaraksa
    Harry J. Whitlow
    Mari Napari
    Leena Meriläinen
    Leona Gilbert
    Microfluidics and Nanofluidics, 2016, 20
  • [9] Development of a microfluidic design for an automatic lab-on-chip operation
    Puttaraksa, Nitipon
    Whitlow, Harry J.
    Napari, Mari
    Merilainen, Leena
    Gilbert, Leona
    MICROFLUIDICS AND NANOFLUIDICS, 2016, 20 (10)
  • [10] Measurement of Dissolved Oxygen with Lab-on-Chip Systems
    Wiest, J.
    Brischwein, M.
    Grothe, H.
    Wolf, B.
    14TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS, 2008, 20 : 353 - +