摘要
This paper presents a technique that utilizes ultrasonic puls-echo method to determine insufficient lubrication in static mechanical components and assemblies. Due to prolong static in-operation of such systems as spring actuated circuit breakers (CB) the lubricants/grease in the actuation mechanism dries up resulting in sluggish response. Since these systems remain static they don't emit any acoustic signals. Therefore active pulse-echo ultrasonic testing method is proposed to determine the lubricant condition. In the proposed method wavelet analysis is used to de-noise the signal and extract data about lubricant condition. The extracted features from different samples is be used to develop a fuzzy inference system to define the lubricant condition.
引用
收藏
页码:166 / 170
页数:5
相关论文
共 50 条
  • [21] The Enhancement of Pulse-echo Ultrasound Signal Using Adaptive Filter with NLMS
    Li, Dongdong
    Wang, Hui
    Deng, Juan
    Zheng, Zheng
    Bu, Zhaohui
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1050 - 1053
  • [22] Elastic properties of Gd3+-doped tellurovanadate glasses using pulse-echo technique
    Saddeek, YB
    MATERIALS CHEMISTRY AND PHYSICS, 2005, 91 (01) : 146 - 153
  • [23] ITERATIVE, PARAMETRIC SPECTRAL ESTIMATION TECHNIQUE FOR HIGH-RESOLUTION PULSE-ECHO ULTRASOUND
    MEYER, CR
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (04) : 207 - 212
  • [24] DUAL-FREQUENCY ULTRASOUND-NEW PULSE-ECHO TECHNIQUE FOR BONE DENSITOMETRY
    Riekkinen, O.
    Hakulinen, M. A.
    Toyras, J.
    Jurvelin, J. S.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (10): : 1703 - 1708
  • [25] Pulse-echo field distribution measurement technique for high-frequency ultrasound sources
    Raum, K
    O'Brien, WD
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1747 - 1750
  • [26] Pulse-echo field distribution measurement technique for high-frequency ultrasound sources
    Raum, K
    OBrien, WD
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (04) : 810 - 815
  • [27] PULSE-ECHO ULTRASOUND SPEED MEASUREMENTS - PROGRESS AND PROSPECTS
    ROBINSON, DE
    OPHIR, J
    WILSON, LS
    CHEN, CF
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (06): : 633 - 646
  • [28] DISTORTION CHARACTERIZATION FOR NONNORMAL INCIDENCE IN PULSE-ECHO ULTRASOUND
    OROFINO, DP
    PEDERSEN, PC
    IEEE 1989 ULTRASONICS SYMPOSIUM : PROCEEDINGS, VOLS 1 AND 2, 1989, : 1073 - 1076
  • [29] Ultrafast Image Acquisition in Pulse-Echo Ultrasound Imaging Using Compressed Sensing
    Schiffner, Martin F.
    Schmitz, Georg
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [30] Ultrasound pulse-echo imaging using the split-step Fourier propagator
    Huang, Lianjie
    Quan, Youli
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513