Direct determination of 3-chloro-1,2-propanediol esters in beef flavoring products by ultra-performance liquid chromatography tandem quadrupole mass spectrometry

被引:9
|
作者
Chai, Qingqing [1 ]
Zhang, Xiaoming [1 ]
Karangwa, Eric [1 ,2 ]
Dai, Qingyuan [1 ,3 ]
Xia, Shuqin [1 ]
Yu, Jingyang [1 ]
Gao, Yahui [1 ]
机构
[1] Jiangnan Univ, Sch Food Sci & Technol, State Key Lab Food Sci & Technol, Lihu Rd 1800, Wuxi 214122, Jiangsu, Peoples R China
[2] AAFUD Ind Zhuhai Co Ltd, Res & Dev, Zhuhai 519085, Guangdong, Peoples R China
[3] Anhui Polytech Univ, Coll Biol & Chem Engn, Beijing Middle Rd, Wuhu 241000, Anhui, Peoples R China
关键词
FATTY-ACID ESTERS; PROCESSING CONTAMINANTS; VEGETABLE-OILS; 3-MCPD ESTERS; EDIBLE OILS; MCPD ESTERS; 3-CHLOROPROPANE-1,2-DIOL; 3-MONOCHLOROPROPANE-1,2-DIOL; SOY; FOODSTUFFS;
D O I
10.1039/c6ra23417h
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A sensitive ultra-performance liquid chromatography tandem quadrupole mass spectrometry (UPLC-TQ-MS) method coupled with amino solid-phase extraction was developed for the direct determination of 3-chloro-1,2-propanediol (3-MCPD) esters which were firstly detected in the natural beef flavoring products. The analyzed 3-MCPD esters in this paper contain three monoesters and six diesters. The validation data indicated that the proposed method provided good linearity, repeatability and sensitivity. The method showed a good linearity within the range of 40-200 mg kg -1 for monoesters and 20-100 mu g kg(-1) for diesters with the determination coefficients (R-2) ranging from 0.9912 to 0.9993. The limits of detection (LODs) for monoesters and diesters of 3-MCPD were in the range of 0.04-5.0 mu g kg(-1) and 0.13-16.0 mu g kg(-1), respectively. The method accuracy was confirmed by higher sample recovery which ranged from 80.5 to 113.7%. The repeatability expressed as intra-day precision ranged from 0.8 to 9.9% and inter-day precision varied from 2.8 to 13.8%. The validated method was successfully applied for determination of 3-MCPD esters in beef flavoring products.
引用
收藏
页码:113576 / 113582
页数:7
相关论文
共 50 条
  • [41] Simultaneous Determination of 9 Mycotoxins in Fruits by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry
    Ni, Yang
    Yang, Junjun
    Shi, Lei
    Zhang, Yingying
    Xiong, Rong
    Science and Technology of Food Industry, 2022, 43 (21) : 302 - 309
  • [42] Determination of hepatotoxic indospicine in Australian camel meat by ultra-performance liquid chromatography - Tandem mass spectrometry
    Fletcher, Mary T. (mary.fletcher@uq.edu.au), 1974, American Chemical Society (62):
  • [43] Determination of olaquindox, carbadox and cyadox in animal feeds by ultra-performance liquid chromatography tandem mass spectrometry
    Miao, Xiaohuan
    Xu, Lijun
    Li, Haipu
    Yang, Zhaoguang
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2018, 35 (07): : 1257 - 1265
  • [44] Determination of Cannabinoids in Breast Milk Using QuEChERS and Ultra-Performance Liquid Chromatography and Tandem Mass Spectrometry
    Ramnarine, Rhea S.
    Poklis, Justin L.
    Wolf, Carl E.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (09) : 746 - 752
  • [45] Determination of 14 local anesthetics in pork by ultra-performance liquid chromatography-tandem mass spectrometry
    Guo, Xuqian
    Ye, Ziyu
    Lei, Chunjuan
    Liu, Hongbin
    Li, Ying
    Han, Xue
    Cai, Yinghua
    Chinese Journal of Analysis Laboratory, 2021, 40 (08) : 948 - 953
  • [46] Determination of phenylephrine in human plasma using ultra-performance liquid chromatography-tandem mass spectrometry
    Feng, Sheng
    Zhao, Qian
    Jiang, Ji
    Hu, Pei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 915 : 28 - 32
  • [47] Determination of lovastatin in human plasma by ultra-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Wang, Dong
    Wang, Dongmei
    Qin, Feng
    Chen, Lingyun
    Li, Famei
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (05) : 511 - 518
  • [48] Determination and Validation of Imperialine in Rat Plasma by Ultra-Performance Liquid-Chromatography with Tandem Mass Spectrometry
    Wu, Qing
    Wang, Chunjie
    Lin, Yingying
    Yang, Suping
    Wu, Yinan
    Fan, Linyu
    Gu, Kaiwen
    Hu, Yue
    Wen, Congcong
    Lin, Chongliang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (09): : 1836 - 1841
  • [49] Application of ultra-performance liquid chromatography-tandem mass spectrometry for the determination of steroid oestrogens in wastewaters
    Petrie, Bruce
    McAdam, Ewan J.
    Richards, Keith H.
    Lester, John N.
    Cartmell, Elise
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (13) : 1343 - 1355
  • [50] Simultaneous Determination of Three Tranquillizers in Lamb Liver by Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry
    Linli Cheng
    Jianzhong Shen
    Qidi Zhang
    Yujie Zhang
    Suxia Zhang
    Food Analytical Methods, 2015, 8 : 1876 - 1882