Does IGRT ensure target dose coverage of head and neck IMRT patients?

被引:24
|
作者
Graff, Pierre
Hu, Weigang [2 ]
Yom, Sue S.
Pouliot, Jean [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, Helen Diller Family Comprehens Canc Ctr, San Francisco, CA 94143 USA
[2] Fudan Univ, Dept Radiat Oncol, Shanghai 200433, Peoples R China
关键词
Head and neck IMRT; Target coverage; Dose recalculation; IGRT; MVCBCT; CONE-BEAM CT; RADIATION-THERAPY; CANCER-PATIENTS; RADIOTHERAPY; REGISTRATION; RECALCULATION; STRATEGIES; DOSIMETRY; GUIDANCE; SYSTEM;
D O I
10.1016/j.radonc.2011.09.024
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine if image-guided radiotherapy (IGRT) ensures dose coverage to the target, and to assess the dosimetric impact of anatomic changes using megavoltage cone-beam CT (MVCBCT) for patient positioning during head and neck IMRT. Methods and materials: Forty-eight MVCBCT from 10 head and neck IMRT/IGRT patients were analyzed off-line. Target volumes and organs at risk (OARS) contours delineated on CT were transferred and adjusted on MVCBCT images. Each MVCBCT was processed to allow dose recalculation, resulting in 469 dose-volume histograms (DVHs). The concept of dosimetric latitude was introduced to provide a clinical perspective. Results: MVCBCT target DVHs showed a moderate level of difference in D95 (dose to >= 95% of volume), generally less than a 5% difference from the planned dose. Delivered-dose increases to the spinal cord and brainstem showed no apparent time trend. The 4 mm margin around OARs was a useful precaution to prevent exceeding critical dose thresholds. The parotid glands showed progressive increases in mean dose related to shrinkage of the external contours. Conclusion: IGRT repositioning ensured target volume coverage, but significant dose variations were observed for OARs. The dosimetric impact of anatomic changes during radiotherapy was of lesser importance than the effects of IGRT repositioning. (C) 2011 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 104 (2012) 83-90
引用
收藏
页码:83 / 90
页数:8
相关论文
共 50 条
  • [21] Patient Dose Metrics Analysis for Head and Neck IMRT
    Li, J.
    Burman, C.
    Parhar, P.
    Schupak, K.
    Chan, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S198 - S199
  • [22] Comparison of IMRT dose prescription for head and neck cancers
    Tung, S
    Lii, M
    Zhu, X
    Garden, A
    MEDICAL PHYSICS, 2004, 31 (06) : 1872 - 1872
  • [23] IMRT and IGRT in head and neck cancer: Have we delivered what we promised?
    Tejpal G.
    JaiPrakash A.
    Susovan B.
    Ghosh-Laskar S.
    Murthy V.
    Budrukkar A.
    Indian Journal of Surgical Oncology, 2010, 1 (2) : 166 - 185
  • [24] Potential of IMRT to escalate dose to head and neck cancers
    Zhou, J
    Kim, J
    Benedict, S
    Wu, Y
    Wu, Q
    MEDICAL PHYSICS, 2002, 29 (06) : 1258 - 1258
  • [25] Evaluation of physical dose variation and biological impact in head and neck IMRT due to minimal setup error-implications for IGRT
    Wada, M.
    Mantle, C.
    Lim Joon, D.
    Rolfo, A.
    Irvine, C.
    Chee, R.
    Feigen, M.
    Rykers, K.
    Khoo, V.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S302 - S302
  • [26] DOES IMRT REDUCE DOSE TO CAROTID ARTERY IN RADIOTHERAPY OF HEAD AND NECK CANCER? A DOSIMETRIC STUDY
    Pandit, S.
    Laviraj, M.
    Pandjatcharam, J.
    Kumar, S.
    Muzumder, S.
    Mohanti, B. K.
    Prabhakar, R.
    Rath, G. K.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S314 - S314
  • [27] Composite minimax robust optimization of VMAT improves target coverage and reduces non-target dose in head and neck cancer patients
    Wagenaar, Dirk
    Kierkels, Roel G. J.
    Free, Jeffrey
    Langendijk, Johannes A.
    Both, Stefan
    Korevaar, Erik W.
    RADIOTHERAPY AND ONCOLOGY, 2019, 136 : 71 - 77
  • [28] Dosimetric consequences of Interobserver target delineation for head and neck IMRT
    Kuritzky, N.
    Morgan, P.
    Li, S.
    Miyamoto, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S1 - S1
  • [29] The effect of target volume depth on surface dose for inverse planned IMRT treatments of head and neck cancers
    Parker, W.
    Poli, E.
    Evans, M.
    Campos, L. Lucente
    Podgorsak, E.
    MEDICAL PHYSICS, 2006, 33 (06) : 2142 - 2142
  • [30] A Method For Estimating Delivered Dose To Head-And-Neck Cancer Patients Treated With IMRT
    Wolf, E.
    Kumar, N.
    Huth, B.
    Lamba, M.
    Elson, H.
    MEDICAL PHYSICS, 2013, 40 (06)