A unique foot-worn device for patients with degenerative meniscal tear

被引:8
|
作者
Elbaz, Avi [1 ]
Beer, Yiftah [2 ]
Rath, Ehud [3 ]
Morag, Guy [3 ]
Segal, Ganit [1 ]
Debbi, Eytan M. [1 ]
Wasser, Daniel [1 ]
Mor, Amit [1 ]
Debi, Ronen [4 ]
机构
[1] AposTherapy Res Grp, Herzliyya, Israel
[2] Assaf Harofeh Med Ctr, Dept Orthoped Surg, IL-70300 Zerifin, Israel
[3] Sourasky Med Ctr, Dept Orthoped Surg, Tel Aviv, Israel
[4] Barzilay Med Ctr, Dept Orthoped Surg, IL-78278 Ashqelon, Israel
关键词
Gait; Meniscal tear; Physical function; Pain; Osteoarthritis; LOW-BACK-PAIN; GAIT ANALYSIS; KNEE OSTEOARTHRITIS; CONSERVATIVE TREATMENT; BIOMECHANICAL DEVICE; ORTHOPEDIC-SURGERY; RANDOMIZED-TRIAL; MATCHED CONTROLS; ELDERLY PERSONS; HEBREW VERSION;
D O I
10.1007/s00167-012-2026-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the current study was to assess the effects of a new foot-worn device on the gait, physical function and pain in patients suffering from knee osteoarthritis (OA) who had a low-impact injury to the medial meniscus causing a degenerative meniscal tear. A retrospective analysis of 34 patients with knee OA and a degenerative medial meniscal tear was performed. Patients underwent a gait evaluation, using an electronic walkway mat, and completed the SF-36 health survey and the WOMAC questionnaire at baseline and after 3 and 12 months of therapy. AposTherapy is a functional, biomechanical, non-invasive rehabilitation therapy consisting of a foot-worn device that is individually calibrated to each patient and is used during activities of daily living. Repeated-measures analyses were performed to compare gait parameters and self-evaluation questionnaires between baseline, and 3 and 12 months. Significant improvements were found in gait velocity, step length and single-limb support of the involved knee following 12 weeks of therapy (all p < 0.01), alongside an improvement in limb symmetry. These results were maintained at the 12-month follow-up examination. Significant improvements were also found in all three domains of the WOMAC index (pain, stiffness and physical function) and in the SF-36 Physical Health Scale and the SF-36 Mental Health Scale (all p < 0.01). Patients with knee OA and a degenerative medial meniscal tear using a biomechanical foot-worn device for a year showed improvement in gait, physical function and pain. Based on the findings of this study, it can be postulated that this biomechanical device might have a positive effect on this population. Therapeutic study, Level IV.
引用
收藏
页码:380 / 387
页数:8
相关论文
共 50 条
  • [21] ASSESSMENT OF MENISCAL EXTRUSION IN PATIENTS WITH DEGENERATIVE MEDIAL MENISCUS ROOT TEAR FOLLOWING SURGICAL TREATMENT
    Burianov, O.
    Lykhodii, V.
    Zadnichenko, M.
    Pshenychnyi, T.
    Lianskorunskyi, V.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2024, 36 : S472 - S472
  • [22] Treatment of degenerative meniscal tear with intrameniscal injection of platelets rich plasma
    Guenoun, D.
    Magalon, J.
    de Torquemada, I
    Vandeville, C.
    Sabatier, F.
    Champsaur, P.
    Jacquet, C.
    Ollivier, M.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (03) : 169 - 176
  • [23] Arthroscopic Partial Meniscectomy versus Sham Surgery for a Degenerative Meniscal Tear
    Sihvonen, Raine
    Paavola, Mika
    Malmivaara, Antti
    Itala, Ari
    Joukainen, Antti
    Nurmi, Heikki
    Kalske, Juha
    Jarvinen, Teppo L. N.
    NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (26): : 2515 - 2524
  • [24] Reliability of using foot-worn devices to measure gait parameters in people with Parkinson's disease
    Lee, Ya-Yun
    Li, Min-Hao
    Luh, Jer-Junn
    Tai, Chun-Hwei
    NEUROREHABILITATION, 2021, 49 (01) : 57 - 64
  • [25] Orientation-Invariant Spatio-Temporal Gait Analysis Using Foot-Worn Inertial Sensors
    Guimaraes, Vania
    Sousa, Ines
    Correia, Miguel Velhote
    SENSORS, 2021, 21 (11)
  • [26] Spatio-temporal gait analysis in children with cerebral palsy using, foot-worn inertial sensors
    Bourgeois, A. Bregou
    Mariani, B.
    Aminian, K.
    Zambelli, P. Y.
    Newman, C. J.
    GAIT & POSTURE, 2014, 39 (01) : 436 - 442
  • [27] The pathologic meniscal flounce: Association with meniscal tear in 10 patients
    Chung, CB
    Dwek, JR
    Mohana-Borges, AV
    Resnick, DL
    RADIOLOGY, 2002, 225 : 328 - 328
  • [28] Objective gait assessment and quantified recurrence analysis using foot-worn wearable sensor for healthy individuals
    Khera, Preeti
    Das, Ratan
    Kumar, Neelesh
    Pankaj, Dinesh
    Singh, Manjeet
    Paul, Sudip
    Mourya, Gajendra Kumar
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [29] 3D gait assessment in young and elderly subjects using foot-worn inertial sensors
    Mariani, Benoit
    Hoskovec, Constanze
    Rochat, Stephane
    Buela, Christophe
    Penders, Julien
    Aminian, Kamiar
    JOURNAL OF BIOMECHANICS, 2010, 43 (15) : 2999 - 3006
  • [30] Comparison of clinical outcomes among patients treated with high tibial osteotomy and meniscal repair of degenerative medial meniscal tear with mild varus deformity
    Hamaoka, Kodai
    Okimura, Shinichiro
    Horita, Kazushi
    Ikeda, Yasutoshi
    Okada, Yohei
    Kamiya, Tomoaki
    Teramoto, Atsushi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)