Validation of a Monte Carlo modelled gamma camera for Lutetium-177 imaging

被引:10
|
作者
Ramonaheng, K. [1 ]
van Staden, J. A. [1 ]
du Raan, H. [1 ]
机构
[1] Univ Free State, Dept Med Phys, POB 339, ZA-9300 Bloemfontein, South Africa
基金
新加坡国家研究基金会;
关键词
Validation; Modelling; Lu-177; Monte Carlo; SIMIND; Simulations; Experiments; Planar; SPECT; QUANTITATIVE SPECT; SCATTER CORRECTION; SIMULATION; DOSIMETRY; QUANTIFICATION; RECONSTRUCTION; THERAPY; ACCURACY; CT;
D O I
10.1016/j.apradiso.2020.109200
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This study validated a model of the Siemens Symbia T16 dual-head SPECT/CT gamma camera created using the Monte Carlo program SIMIND for Lu-177. The validation was done by comparing experimental and simulated gamma camera performance criteria tests for the Lu-177 208 keV photopeak with a medium-energy collimator. Results showed good agreement between the experimental and simulated values. These results illustrated that SIMIND could emulate the Symbia T16 successfully and therefore, can be used with confidence to model (177) Lu images.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] SIMIND Monte Carlo validation for Lutetium-177 imaging
    Ramonaheng, Keamogetswe
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [2] Validation of Tc-99m and Lu-177 quantification parameters for a SIMIND Monte Carlo modelled gamma camera
    Kamrani, S.
    Sheikhzadeh, P.
    Kamali-Asl, A.
    Rahmim, A.
    Akhavanallaf, A.
    Aghamiri, S.
    Darvishi, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S695 - S696
  • [3] Validation of a SIMIND Monte Carlo modelled gamma camera for Iodine-123 and Iodine-131 imaging
    Morphis, Michaella
    van Staden, Johan A.
    du Raan, Hanlie
    Ljungberg, Michael
    HELIYON, 2021, 7 (06)
  • [4] Validation of 99mTc and 177Lu quantification parameters for a Monte Carlo modelled gamma
    Di Domenico, Giovanni
    Di Biaso, Simona
    Longo, Lorenzo
    Turra, Alessandro
    Tonini, Eugenia
    Longo, MariaConcetta
    Uccelli, Licia
    Bartolomei, Mirco
    EJNMMI PHYSICS, 2023, 10 (01):
  • [5] Energy window and collimator optimization in lutetium-177 single-photon emission computed tomography imaging using Monte Carlo simulation
    Asmi, Hicham
    Bentayeb, Farida
    Bouzekraoui, Youssef
    Bonutti, Faustino
    Douama, Sanae
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2020, 35 (01): : 36 - 39
  • [6] Quantitative SPECT/CT Imaging of Lutetium-177 (177Lu): a comparison of methods
    Wevrett, J.
    Scuffham, J.
    Fenwick, A.
    Robinson, A.
    Nisbet, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S250 - S250
  • [7] Monte Carlo modelling of a compact CZT-based gamma camera with application to 177Lu imaging
    Roth, Daniel
    Larsson, Erik
    Ljungberg, Michael
    Gleisner, Katarina Sjogreen
    EJNMMI PHYSICS, 2022, 9 (01)
  • [8] Investigation of a portable gamma camera with pinhole collimator for Lu-177 imaging using Monte Carlo simulations
    Papadimitroulas, P.
    Savvidis, G.
    Fysikopoulos, E.
    Georgiou, M.
    Lamprou, E.
    Chatzipapas, K.
    Loudos, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S341 - S341
  • [9] Monte Carlo modelling of a compact CZT-based gamma camera with application to 177Lu imaging
    Daniel Roth
    Erik Larsson
    Michael Ljungberg
    Katarina Sjögreen Gleisner
    EJNMMI Physics, 9
  • [10] Inter-comparison of quantitative imaging of lutetium-177 (177Lu) in European hospitals
    Wevrett, Jill
    Fenwick, Andrew
    Scuffham, James
    Johansson, Lena
    Gear, Jonathan
    Schlogl, Susanne
    Segbers, Marcel
    Sjogreen-Gleisner, Katarina
    Solny, Pavel
    Lassmann, Michael
    Tipping, Jill
    Nisbet, Andrew
    EJNMMI PHYSICS, 2018, 5