Refinement of insulator-based dielectrophoresis

被引:41
|
作者
Crowther, Claire V. [1 ]
Hayes, Mark A. [1 ]
机构
[1] Arizona State Univ, Sch Mol Sci, Mail Stop 1604, Tempe, AZ 85287 USA
基金
美国国家卫生研究院;
关键词
ELECTRODELESS DIELECTROPHORESIS; ELECTRIC-FIELDS; SEPARATION; MANIPULATION; DNA; DEVICES; ARRAYS; CELLS; GEOMETRY; CAPTURE;
D O I
10.1039/c6an02509a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The ability to separate analytes with increasingly similar properties drives the field of separation science. One way to achieve such separations is using trapping and streaming dielectrophoresis (DEP), which directly exploits the subtle differences in the electrophysical properties of analytes. The non-uniform fields necessary for DEP can be formed using various insulator shapes in microchannels. Current insulator shapes include triangles, diamonds, circles, and rectangles. However, all of these insulators pose problems for trapping, streaming, and sorting (deflection) as the induced fields/gradients are not behaviorally consistent across the lateral dimension. This leads to analytes experiencing different forces depending on their pathline in the microchannel and result in low resolution separations. Based on an iterative process that explored approximately 40 different insulator shapes, a design was chosen that indicated improved particle streamlines, better trapping efficiency, and consistent electrical environments across the lateral dimension. The design was assessed by simulations where the electric field, gradient of the electric field squared, and the ratio of the two were plotted. The improved design includes a unique new multi-length scale element. The multi-length scale structure streamlines the analyte(s) and improves homogeneity in the lateral dimension, while still achieving high gradients necessary for analyte separation using DEP. The design is calculated to keep analytes on the centerline which should improve resolution, and eliminate extraneous trapping zones. Behaviors consistent with the features of the simulations were observed in proof of principle experiments using representative test probes.
引用
收藏
页码:1608 / 1618
页数:11
相关论文
共 50 条
  • [11] Hydrodynamic separation of cells utilizing insulator-based dielectrophoresis
    Jen, Chun-Ping
    Huang, Ching-Te
    Shih, Hsin-Yuan
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2010, 16 (07): : 1097 - 1104
  • [12] Hydrodynamic Separation of Cells Utilizing Insulator-based Dielectrophoresis
    Jen, Chun-Ping
    Huang, Ching-Te
    Shih, Hsin-Yuan
    DTIP 2009: SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS, 2009, : 55 - 59
  • [13] Dielectrophoretic mobility determination in DC insulator-based dielectrophoresis
    Weiss, Noah G.
    Jones, Paul V.
    Mahanti, Prasun
    Chen, Kang P.
    Taylor, Thomas J.
    Hayes, Mark A.
    ELECTROPHORESIS, 2011, 32 (17) : 2292 - 2297
  • [14] Fast and selective concentration of pathogens by insulator-based dielectrophoresis
    Cummings, Eric B.
    Simmons, Blake A.
    Davalos, R. V.
    McGraw, G. J.
    Lapizco-Encinas, B. H.
    Fintschenko, Yolanda
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U404 - U405
  • [15] Development of the resolution theory for gradient insulator-based dielectrophoresis
    Jones, Paul V.
    Hayes, Mark A.
    ELECTROPHORESIS, 2015, 36 (9-10) : 1098 - 1106
  • [16] Assessment of microalgae viability employing insulator-based dielectrophoresis
    Roberto C. Gallo-Villanueva
    Nadia M. Jesús-Pérez
    José I. Martínez-López
    Adriana Pacheco
    Blanca H. Lapizco-Encinas
    Microfluidics and Nanofluidics, 2011, 10 : 1305 - 1315
  • [17] High sensitivity three-dimensional insulator-based dielectrophoresis
    Braff, William A.
    Pignier, Alexandre
    Buie, Cullen R.
    LAB ON A CHIP, 2012, 12 (07) : 1327 - 1331
  • [18] Isolation and enrichment of low abundant particles with insulator-based dielectrophoresis
    LaLonde, Alexandra
    Romero-Creel, Maria F.
    Saucedo-Espinosa, Mario A.
    Lapizco-Encinas, Blanca H.
    BIOMICROFLUIDICS, 2015, 9 (06):
  • [19] Concentration of Sindbis virus with optimized gradient insulator-based dielectrophoresis
    Ding, Jie
    Lawrence, Robert M.
    Jones, Paul V.
    Hogue, Brenda G.
    Hayes, Mark A.
    ANALYST, 2016, 141 (06) : 1997 - 2008
  • [20] Three dimensional passivated-electrode insulator-based dielectrophoresis
    Nakidde, Diana
    Zellner, Phillip
    Alemi, Mohammad Mehdi
    Shake, Tyler
    Hosseini, Yahya
    Riquelme, Maria V.
    Pruden, Amy
    Agah, Masoud
    BIOMICROFLUIDICS, 2015, 9 (01):