Continuous Cuffless Blood Pressure Measurement using PPG and ECG

被引:0
|
作者
Kusumah, Ilman Himawan [1 ]
Setiawan, Agung W. [1 ]
机构
[1] Inst Teknol Bandung, Sch Elect Engn & Informat, Bandung, Indonesia
关键词
Continuous blood pressure; cuffless; PTT; PIR; wearable; ambulatory; clinical standards;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Continuous blood pressure changes monitoring with regular time intervals conventionally is performed by auscultatory and oscillometric measurement techniques. It has limitations on the patient naturality and inconvenience because of repeated arm pumping. This study aims to determine a method of blood pressure measurement that has continuous monitoring, cuffless, wearable and ambulatory measurement features and accuracy of clinical standards. The configuration uses PPG sensor and lead-1 ECG to obtain the PTT and PIR parameter. The parameter used to determine systolic and diastolic blood pressure. Tests performed on 40 healthy subjects in seated, stand and lying down position. The results prototypes have a mean +/- standard deviation (SD) to estimate of systolic, diastolic and pulse pressure were 0.55 +/- 7.42 mmHg, 0.37 +/- 7.20mmHg, 0.08 +/- 10.07mmHg, respectively. The MAD of systolic, diastolic and pulse pressure were 6.02 mmHg, 6.00 mmHg, and 8.03 mmHg, respectively. The highest correlation between estimated and reference blood pressure had Rsquare 0.719 for diastolic and 0.672 for systolic. Regression analysis for each subject between PTT and pulse pressure with highest Rsquare is 0,894 and for PIR and diastole is 0,663.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [21] Improving the Performance of Continuous Non-invasive Estimation of Blood Pressure Using ECG and PPG
    Bose, S. Sree Niranjanaa
    Kumar, C. Santhosh
    2015 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2015,
  • [22] Towards a Continuous Non-Invasive Cuffless Blood Pressure Monitoring System Using PPG: Systems and Circuits Review
    Wang, Guoxing
    Atef, Mohamed
    Lian, Yong
    IEEE CIRCUITS AND SYSTEMS MAGAZINE, 2018, 18 (03) : 6 - 26
  • [23] DiffCNBP: Lightweight Diffusion Model for IoMT-Based Continuous Cuffless Blood Pressure Waveform Monitoring Using PPG
    Ma, Chenbin
    Guo, Lishuang
    Zhang, Haonan
    Liu, Zhenchang
    Zhang, Guanglei
    IEEE INTERNET OF THINGS JOURNAL, 2025, 12 (01): : 61 - 80
  • [24] MLP-BP: A novel framework for cuffless blood pressure measurement with PPG and ECG signals based on MLP-Mixer neural networks
    Huang, Bin
    Chen, Weihai
    Lin, Chun-Liang
    Juang, Chia-Feng
    Wang, Jianhua
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 73
  • [25] Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations
    Joung, Jingon
    Jung, Chul-Woo
    Lee, Hyung-Chul
    Chae, Moon-Jung
    Kim, Hae-Sung
    Park, Jonghun
    Shin, Won-Yong
    Kim, Changhyun
    Lee, Minhyung
    Choi, Changwoo
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [26] Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations
    Jingon Joung
    Chul-Woo Jung
    Hyung-Chul Lee
    Moon-Jung Chae
    Hae-Sung Kim
    Jonghun Park
    Won-Yong Shin
    Changhyun Kim
    Minhyung Lee
    Changwoo Choi
    Scientific Reports, 13
  • [27] Cuffless Blood Pressure Measurement Using a Smartphone-Case Based ECG Monitor with Photoplethysmography in Hypertensive Patients
    Sagirova, Zhanna
    Kuznetsova, Natalia
    Gogiberidze, Nana
    Gognieva, Dania
    Suvorov, Aleksandr
    Chomakhidze, Petr
    Omboni, Stefano
    Saner, Hugo
    Kopylov, Philippe
    SENSORS, 2021, 21 (10)
  • [28] Comparison of Different Machine Learning Techniques for the Cuffless Estimation of Blood Pressure using PPG Signals
    Kilickaya, Sertac
    Guner, Aytug
    Dal, Baris
    2ND INTERNATIONAL CONGRESS ON HUMAN-COMPUTER INTERACTION, OPTIMIZATION AND ROBOTIC APPLICATIONS (HORA 2020), 2020, : 319 - 324
  • [29] Live Demonstration: A Novel Cuffless Photoplethysmography Sensor for Continuous Blood Pressure measurement
    Kao, Yung-Hua
    Chao, Paul C. -P.
    Hung, Yueh
    Wey, Chin-Long
    2017 IEEE SENSORS, 2017, : 470 - 470
  • [30] A Calibration Method for Cuffless Continuous Blood Pressure Measurement using Gaussian Normalized Pulse Transit Time
    Xu, Yang
    Zhang, Weigong
    Wang, Dong
    Ping, Peng
    2018 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC): DISCOVERING NEW HORIZONS IN INSTRUMENTATION AND MEASUREMENT, 2018, : 152 - 156