Measurement of chlorine concentration on steel surfaces via fiber-optic laser-induced breakdown spectroscopy in double-pulse configuration

被引:40
|
作者
Xiao, X. [1 ,2 ]
Le Berre, S. [2 ]
Fobar, D. G. [1 ]
Burger, M. [1 ,4 ]
Skrodzki, P. J. [1 ,4 ]
Hartig, K. C. [2 ,3 ]
Motta, A. T. [2 ]
Jovanovic, I. [1 ,4 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
[2] Penn State Univ, Dept Mech & Nucl Engn, University Pk, PA 16802 USA
[3] Univ Florida, Nucl Engn Program, Gainesville, FL 32611 USA
[4] Univ Michigan, Ctr Ultrafast Opt Sci, Ann Arbor, MI 48109 USA
关键词
Laser-induced breakdown spectroscopy (LIBS); Optical fiber; Remote inspection; Double pulse; Chlorine; ELEMENTAL ANALYSIS; PLASMA; CONCRETE; LIBS; ENHANCEMENT; ABLATION; ALLOYS; SYSTEM; PROBE;
D O I
10.1016/j.sab.2018.01.003
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The corrosive environment provided by chlorine ions on the welds of stainless steel dry cask storage canisters for used nuclear fuel may contribute to the occurrence of stress corrosion cracking. We demonstrate the use of fiber-optic laser-induced breakdown spectroscopy (FOLIBS) in the double-pulse (DP) configuration for high-sensitivity, remote measurement of the surface concentrations of chlorine compatible in constrained space and challenging environment characteristic for dry cask storage systems. Chlorine surface concentrations as low as 5 mg/m(2) have been detected and quantified by use of a laboratory-based and a fieldable DP FOLIBS setup with the calibration curve approach. The compact final optics assembly in the fieldable setup is interfaced via two 25-m long optical fibers for high-power laser pulse delivery and plasma emission collection and can be readily integrated into a multi-sensor robotic delivery system for in-situ inspection of dry cask storage systems. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:44 / 52
页数:9
相关论文
共 50 条
  • [41] Orthogonal and Collinear Configurations in Double-Pulse Laser-Induced Breakdown Spectrometry to Improve Sensitivity in Chlorine Determination
    A. S. Zakuskin
    A. M. Popov
    S. M. Zaytsev
    N. B. Zorov
    M. V. Belkov
    T. A. Labutin
    Journal of Applied Spectroscopy, 2017, 84 : 319 - 323
  • [42] DOUBLE-PULSE LASER-INDUCED BREAKDOWN SPECTROSCOPY WITH 1030 AND 257.5 nm WAVELENGTH FEMTOSECOND LASER PULSES
    Balachninaite, O.
    Baskevicius, A.
    Stankeviciute, K.
    Kurselis, K.
    Sirutkaitis, V.
    LITHUANIAN JOURNAL OF PHYSICS, 2010, 50 (01): : 105 - 110
  • [43] Fiber-optic spark delivery for gas-phase laser-induced breakdown spectroscopy
    Dumitrescu, Cosmin
    Puzinauskas, Paulius
    Olcmen, Semih
    Buckley, Steven G.
    Joshi, Sachin
    Yalin, Azer P.
    APPLIED SPECTROSCOPY, 2007, 61 (12) : 1338 - 1343
  • [44] Orthogonal and Collinear Configurations in Double-Pulse Laser-Induced Breakdown Spectrometry to Improve Sensitivity in Chlorine Determination
    Zakuskin, A. S.
    Popov, A. M.
    Zaytsev, S. M.
    Zorov, N. B.
    Belkov, M. V.
    Labutin, T. A.
    JOURNAL OF APPLIED SPECTROSCOPY, 2017, 84 (02) : 319 - 323
  • [45] Measurement of uranium in a glass matrix based on spatial confinement using fiber-optic laser-induced breakdown spectroscopy
    Guo, Xinyu
    Wu, Jian
    Li, Jinghui
    Shi, Mingxin
    Zhu, Xinxin
    Zhou, Ying
    Wu, Di
    Song, Ziyuan
    Huang, Sijun
    Li, Xingwen
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (11) : 2716 - 2727
  • [46] Rapid classification of steel via a modified support vector machine algorithm based on portable fiber-optic laser-induced breakdown spectroscopy
    Yuan, Mengtian
    Zeng, Qingdong
    Wang, Jie
    Li, Wenxin
    Chen, Guanghui
    Li, Zitao
    Liu, Yang
    Guo, Lianbo
    Li, Xiangyou
    Yu, Huaqing
    OPTICAL ENGINEERING, 2021, 60 (12)
  • [47] Investigation of the osteitis deformans phases in snake vertebrae by double-pulse laser-induced breakdown spectroscopy
    Galiova, M.
    Kaiser, J.
    Novotny, K.
    Ivanov, M.
    Fisakova, M. Nyvltova
    Mancini, L.
    Tromba, G.
    Vaculovic, T.
    Liska, M.
    Kanicky, V.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (02) : 1095 - 1107
  • [48] Measurement of concentration of chlorine attached to a stainless-steel canister material using laser-induced breakdown spectroscopy
    Eto, Shuzo
    Tani, Junichi
    Shirai, Koji
    Fujii, Takashi
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 87 : 74 - 80
  • [49] Effect of target composition on the emission enhancement observed in Double-Pulse Laser-Induced Breakdown Spectroscopy
    Cristoforetti, G.
    Legnaioli, S.
    Palleschi, V.
    Salvetti, A.
    Tognoni, E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (02) : 312 - 323
  • [50] Effect of parameters on Si plasma emission in collinear double-pulse laser-induced breakdown spectroscopy
    Fang-Fang Chen
    Xue-Jiao Su
    Wei-Dong Zhou
    Frontiers of Physics, 2015, 10