Factors affecting range of motion in total knee arthroplasty using high flexion prosthesis: A prospective study

被引:20
|
作者
Sancheti, Kantilal H. [1 ]
Sancheti, Parag K. [1 ]
Shyam, Ashok K. [1 ]
Joshi, Rajeev [1 ]
Patil, Kailash [1 ]
Jain, Anubhav [1 ]
机构
[1] Sancheti Inst Orthopaed & Rehabil, Dept Arthroplasty, Pune, Maharashtra, India
关键词
High flex knee prosthesis; range of motion; total knee arthroplasty; FOLLOW-UP; POSTOPERATIVE FLEXION; REPLACEMENT; TRIAL; MOVEMENT; STANDARD; SURGERY; BEARING; PATIENT; DESIGNS;
D O I
10.4103/0019-5413.106901
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: High flexion implants have been reported to provide better range of motion (ROM). The few studies analyzing the factors affecting the ROM are scarce. This study aims to find the factors that affect ROM when using a high flex knee design (INDUS knee). Materials and Methods: Two hundred and fifty three consecutive patients of total knee arthroplasty (TKA) done by using INDUS knee prosthesis between Sept 2008 and Sept 2009 were included in the study. The cases with osteoarthritis (OA) and Rheumatoid arthritis (RA) were included in study. 5 patients were lost to followup and 248 patients (267 knees, 19 bilateral, 221 OA, and 46 RA) were analyzed for the following factors - sex, age, body mass index (BMI), preoperative ROM, flexion deformity, preoperative total knee score and functional score, time of tourniquet release and patella resurfacing. Subgroup classification using above factors was performed and statistical analysis of effect of all the above factors on final knee ROM was done. Assessment was done preoperatively and at 3 months, 6 months and 1 year postoperatively. The final outcome evaluation was done at one year followup. Results: The mean age was 68.2 years (range 40-89 years) with 79 males and 189 females. The mean knee range improved from 97.62 11 degrees to 132 8 degrees. Factors that positively affect ROM of INDUS knee prosthesis at the end of 1 year were preoperative ROM, total knee score and functional score, and diagnosis of osteoarthritis, whereas BMI, preoperative flexion deformity has a negative influence on final flexion at the end of 1 year. Age and gender of the patients, patella resurfacing, and use of two different tourniquet protocols did not affect the final outcome. Conclusion: Preoperative ROM and preoperative functional status are the most important factors affecting final range. Patients should be counseled accordingly and made to understand these factors.
引用
收藏
页码:50 / 56
页数:7
相关论文
共 50 条
  • [41] Effect of surgical closing in total knee arthroplasty at flexion or extension: a prospective, randomized study
    Komurcu, Erkam
    Yuksel, Halil Yalcin
    Ersoz, Murat
    Aktekin, Cem Nuri
    Hapa, Onur
    Celebi, Levent
    Akbal, Ayla
    Bicimoglu, Ali
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 3067 - 3073
  • [42] THE NATURAL-HISTORY OF FLEXION CONTRACTURE IN TOTAL KNEE ARTHROPLASTY - A PROSPECTIVE-STUDY
    TANZER, M
    MILLER, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (248) : 129 - 134
  • [43] Effect of surgical closing in total knee arthroplasty at flexion or extension: a prospective, randomized study
    Erkam Kömürcü
    Halil Yalçın Yüksel
    Murat Ersöz
    Cem Nuri Aktekin
    Onur Hapa
    Levent Çelebi
    Ayla Akbal
    Ali Biçimoğlu
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 3067 - 3073
  • [44] Continuous passive motion after total knee arthroplasty - A prospective study
    Chen, BQ
    Zimmerman, JR
    Soulen, L
    DeLisa, JA
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2000, 79 (05) : 421 - 426
  • [45] Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs. substituting designs
    Seon, Jong-Keun
    Park, Ju-Kwon
    Shin, Young-Joo
    Seo, Hyung-Yeon
    Lee, Keun-Bae
    Song, Eun-Kyoo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (12) : 2016 - 2022
  • [46] Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs. substituting designs
    Jong-Keun Seon
    Ju-Kwon Park
    Young-Joo Shin
    Hyung-Yeon Seo
    Keun-Bae Lee
    Eun-Kyoo Song
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 2016 - 2022
  • [47] Clinical evaluation of 292 Genesis II posterior stabilized high-flexion total knee arthroplasty: Range of motion and predictors
    Fuchs M.C.H.W.
    Janssen R.P.A.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (1) : 161 - 166
  • [48] Range of Motion of Standard and High-Flexion Cruciate Retaining Total Knee Prostheses
    Minoda, Yukihide
    Aihara, Masaharu
    Sakawa, Akira
    Fukuoka, Shinichi
    Hayakawa, Keiko
    Ohzono, Kenji
    JOURNAL OF ARTHROPLASTY, 2009, 24 (05): : 674 - 680
  • [49] No difference between standard and high flexion cruciate retaining total knee arthroplasty: a prospective randomised controlled study
    Springorum, Hans Robert
    Maderbacher, Guenther
    Craiovan, Benjamin
    Luering, Christian
    Baier, Clemens
    Grifka, Joachim
    Keshmiri, Armin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (06) : 1591 - 1597
  • [50] No difference between standard and high flexion cruciate retaining total knee arthroplasty: a prospective randomised controlled study
    Hans Robert Springorum
    Günther Maderbacher
    Benjamin Craiovan
    Christian Lüring
    Clemens Baier
    Joachim Grifka
    Armin Keshmiri
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1591 - 1597