A scoring framework and apparatus for epilepsy seizure detection using a wearable belt

被引:1
|
作者
Alzghoul, Salah Eldeen Mofleh Falah [1 ]
Alajlouni, Saed Ahmad Qwaiteen [2 ]
机构
[1] Hashemite Univ, Fac Engn, Dept Biomed Engn, Zarqa, Jordan
[2] Hashemite Univ, Fac Engn, Dept Mechatron Engn, Zarqa, Jordan
来源
JOURNAL OF MEDICAL SIGNALS & SENSORS | 2022年 / 12卷 / 04期
关键词
Alarm system; electromyography; epilepsy seizures; heart rate; smart health-care system; wearable; DETECTION SYSTEMS; EPIDEMIOLOGY; LONG;
D O I
10.4103/jmss.jmss_138_21
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To develop a wearable device that can detect epilepsy seizures. In particular, due to their prevalence, attention is focused on detecting the generalized tonic-clonic seizure (GTCS) type. When a seizure is detected, an alert phone call is initiated and an alarm SMS sent to the nearest health-care provider (and/or a predesignated family member), including the patient's location as global positioning system (GPS) coordinates. A wearable belt is developed including an Arduino processor that constantly acquires data from four different sensing modalities and monitors the acquired signal patterns for abnormalities. The sensors are a heart rate sensor, electromyography sensor, blood oxygen level (oxygen saturation) sensor, and an accelerometer to detect sudden falls. Higher-than-normal threshold levels are established for each sensor's signal. If two or more signal measurements exceed the corresponding threshold value for a predetermined time interval, then the seizure alarm is triggered. Clinical trials were not pursued in this study as this is the initial phase of system development (phase 0). Instead, the instrumented belt seizure detection prototype was tested on nine healthy individuals mimicking, to some degree, seizure symptoms. A total of eighteen trials took place of which half had < 2 sensor thresholds exceeded and no alarm, whereas the other half resulted in activating the alarm when two or more sensor thresholds were exceeded for at least the predetermined time interval corresponding to each of the higher-than-normal sensor readings. For each trial that triggered the alarm when a seizure was detected, the on-board GPS and global system for mobile communication (GSM) units successfully initiated an alert phone call to a predesignated number in addition to sending an SMS message, including GPS location coordinates. Continuous real-time monitoring of signals from the four different sensors allows the developed wearable belt to detect GTCS while reducing false alarms. The proposed device produces an important alarm that may save a patient's life.
引用
收藏
页码:339 / 346
页数:8
相关论文
共 50 条
  • [21] Optimizing Electrode Configurations for Wearable EEG Seizure Detection Using Machine Learning
    Gelbard-Sagiv, Hagar
    Pardo, Snir
    Getter, Nir
    Guendelman, Miriam
    Benninger, Felix
    Kraus, Dror
    Shriki, Oren
    Ben-Sasson, Shay
    SENSORS, 2023, 23 (13)
  • [22] Epilepsy Seizure Detection and Prediction using an Approximate Spiking Convolutional Transformer
    Chen, Qinyu
    Sun, Congyi
    Gao, Chang
    Liu, Shih-Chii
    2024 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, ISCAS 2024, 2024,
  • [23] Automatic seizure detection framework
    Gasca, F.
    Tech, R.
    Wagner, M.
    Kastner, J.
    Fuchs, M.
    EPILEPSIA, 2022, 63 : 99 - 99
  • [24] A deep learning approach for epilepsy seizure detection using EEG signals
    Kaushik, Manoj
    Singh, Divyanshu
    Kishore-Dutta, Malay
    Travieso, Carlos M.
    TECNOLOGIA EN MARCHA, 2022, 35
  • [25] An Efficient Automated Technique for Epilepsy Seizure Detection Using EEG signals
    Lasefr, Zakareya
    Ayyalasomayajula, Sai Shiva V. N. R.
    Elleithy, Khaled
    2017 IEEE 8TH ANNUAL UBIQUITOUS COMPUTING, ELECTRONICS AND MOBILE COMMUNICATION CONFERENCE (UEMCON), 2017, : 76 - 82
  • [26] Detection of Seizure and Epilepsy Using Higher Order Statistics in the EMD Domain
    Alam, S. M. Shafiul
    Bhuiyan, M. I. H.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2013, 17 (02) : 312 - 318
  • [27] Detection is Key: Automated Tonic Seizure Detection With a Wearable Device
    Fine, Anthony L.
    EPILEPSY CURRENTS, 2025, 25 (01) : 36 - 38
  • [28] Wearable Belt Resonators Model for Wrist Detection
    Lee, Chieh-Sen
    Wu, Chun-Yih
    Kuo, Yen-Liang
    2016 IEEE 5TH ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP 2016), 2016, : 35 - 36
  • [29] Prospective Study of a Multimodal Convulsive Seizure Detection Wearable System on Pediatric and Adult Patients in the Epilepsy Monitoring Unit
    Onorati, Francesco
    Regalia, Giulia
    Caborni, Chiara
    LaFrance, W. Curt
    Blum, Andrew S.
    Bidwell, Jonathan
    De Liso, Paola
    El Atrache, Rima
    Loddenkemper, Tobias
    Mohammadpour-Touserkani, Fatemeh
    Sarkis, Rani A.
    Friedman, Daniel
    Jeschke, Jay
    Picard, Rosalind
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [30] Wearable Electromagnetic Belt for Steatotic Liver Detection Using Multivariate Energy Statistics
    Rezaeieh, Sasan Ahdi
    Brankovic, Aida
    Janani, Azin S.
    Mohammed, Beadaa
    Darvazehban, Amin
    Zamani, Ali
    Macdonald, Graeme A.
    Abbosh, Amin M.
    IEEE ACCESS, 2020, 8 (08): : 201847 - 201860